Recent updates
Updates
Your BMC Helix Discovery instances are updated monthly, and you will receive an email notification in accordance with our notification policy.
For BMC Helix Discovery, each month's TKU is applied to Non-Prod and Prod instances on the advised dates. The included BMC Discovery Outpost is automatically updated by default unless you have configured manual updating. If you have configured manual updating, ensure that you apply the updates as soon as is practical. Otherwise, there could be a mismatch between BMC Helix Discovery and the BMC Discovery Outpost that might result in an incorrect model or slightly degraded discovery. See Configuring the BMC Discovery Outpost for more information on configuring automatic updates.
The TKU changes that occur each month enhance the capabilities of, and sometimes these changes alter, the model. If you have a single Outpost operating with your Non-Prod and Prod instances, the Outpost is updated to the latest Non-Prod version, causing a mismatch between the Outpost version and your Prod instance. Occasionally, this mismatch might result in an incorrect model or slightly degraded discovery, and would be noted in the updates table below. The mismatch will persist until the next update and is likely to be infrequent. This situation can be avoided by installing a separate Outpost for your Non-Prod and Prod instances.
More information about TKU content and schedules is available in the BMC Discovery content reference (Configipedia).
Generally available 2026 enhancements
The following updates have been released in 2026.
April 2026
This is the release of BMC Helix Discovery version 26.2.
This version of BMC Helix Discovery introduces the following enhancements:
- Deep container discovery enhancements
- Discover communication relationships for software running in containers
- Container-to-container links
- Links from contained software to external software and load balancer services
- Automatic modeling of custom software running in containers
- Data model consistency improvements
- BMC Helix Discovery stores contained software in the "contained" partition in the datastore. You can view contained software by adding the Containerized Software channel to your dashboard view. See Default dashboards and Customizing dashboards for more information.
- Discover communication relationships for software running in containers
- The UI and workflow for creating service models and rules templates by using a visual query has been improved.
- Named values are supported. A named value is a text variable whose value is derived from a starting attribute on the node by a transformation.
- The notes editor has been improved and now supports reStructuredText in addition to the previously supported formatting.
- Mainframe Discovery using the legacy agent API (NVBAPI) is deprecated in BMC Helix Discovery 26.2 and will be removed in a future release. It is replaced by the REST-based Mainframe API provider.
The 26.2 version of BMC Helix Discovery applies the Technology Knowledge Update TKU 2026-May-1 and resolves the following defects:
| Description | Defect ID |
|---|---|
| Connections to Postgress are not re-opened having failed with "server closed the connection unexpectedly". | DRUD1-51497, DRUD1-51658, DRUD1-51844, DRUD1-51343, DRUD1-51526. |
| Queries with parameters saved in "Favorite Queries" may fail with "Invalid conditions". | DRUD1-51518. |
| The Outpost credential import button can be clicked repeatedly. | DRUD1-50580, DRUD1-50302. |
| The TKU update does not complete during BMC Helix Discovery upgrades. | DRUD1-48267, DRUD1-51759, DRUD1-51761, DRUD1-47807, DRUD1-50034, DRUD1-50969, DRUD1-51050, DRUD1-51411, DRUD1-51513, DRUD1-51685, DRUD1-51691, DRUD1-51703, DRUD1-51741, DRUD1-51757, DRUD1-51756. |
| Cloud Database nodes are not synchronized with the ServiceNow CMDB. | DRUD1-42396, DRUD1-51834. |
| License use of hosts created by BMC Helix Operations Management and BMC Helix Intelligent Integrations is unclear. | DRUD1-46557, DRUD1-33690, DRUD1-48417, DRUD1-50376. |
| Query function friendly_duration does not work as expected. | DRUD1-51521, DRUD1-51267. |
| vCenter API not returning network interface information. | DRUD1-51282, DRUD1-50927, DRUD1-51633, DRUD1-50970. |
| Discovery of a Linux server fails with "NoAccess (Host identification failure - no mac addresses)". | DRUD1-51921, DRUD1-51806. |
| Receiver restart during inferred sync resync caused synced data to be destroyed. | DRUD1-51661, DRUD1-51769. |
| A discovery run did not create a Heuristic node for ManagementController and iterates through credentials until an error is returned. | DRUD1-50321, DRDC1-24168, DRDC1-24836, DRDC1-24763, DRDC1-24938. |
| SoftwareInstance ElementUsingFile relationship is not visible in UI. | DRUD1-51135, DRUD1-51125. |
| Query generated by Visual query with "Before condition" does not return the expected output. | DRUD1-51094, DRUD1-51017. |
| CMDB Services Sync removes relationships in BMC Helix Discovery while they're still present in the CMDB. | DRUD1-51175, DRUD1-50052, DRUD1-50742. |
| The Technical difficulties page is displayed when attempting to view a StorageSystem. | DRUD1-51272, DRUD1-51865, DRUD1-50196, DRUD1-51366, DRUD1-51622, DRUD1-51837, DRUD1-51842, DRUD1-54182. |
| The SQL Query Result node does not have a link to related credential. | DRUD1-58782, DRDC1-28811. |
March 2026
This is the release of BMC Helix Discovery version 26.1.02.
This version of BMC Helix Discovery introduces the following enhancements:
- Integration with third-party credential manager ARCON PAM Digital Vault. The ARCON PAM Digital Vault is application software that stores and manages credentials securely, according to the policies that your organization implements. For the BMC Helix Discovery instance to be able to access the ARCON PAM Digital Vault, you must perform the integration from the BMC Discovery Outpost on the Manage > Vault Providers page.
- The CyberArk CCP REST API integration supports a Custom URL path so that the specified URL can be used without any default additions.
- CAM definitions can now be added to a group which does not already contain any functional component definitions.
- The receiver queue size is displayed in the Consolidation UI.
The 26.1.02 version of BMC Helix Discovery applies the Technology Knowledge Update TKU 2026-Apr-1 and resolves the following defects:
| Description | Defect ID |
|---|---|
| Data other than "Cluster" disappears from the previous discovery run node page after the next scan. | DRUD1-47122, DRDC1-23008, DRDC1-25836 |
| Inferred Sync Discovery Run stops if the connection is deleted during the scan. | DRUD1-53692, DRUD1-54868 |
| Disabled CMDB Sync configurations were performing server checks, and failed connections were logged. | DRUD1-51051 |
| Unable to add/configure "REST API with OAuth2 authentication" credential using CyberArk Enterprise Platform Vault or HashiCorp Vault. | DRUD1-52596, DRUD1-52466 |
| Removed FQDN does remains in the parent device node. | DRUD1-58185 |
| Occasionally the reasoning parent process can get stuck and result in 504 errors in the UI. | DRUD1-58435, DRUD1-58429 |
| No Inferred Entity or direct access on the Discovery Access UI page to the inferred nodes from API scans. | DRUD1-54550, DRUD1-54339 |
| Some Windows hosts discovered with WMI are missing File Systems. | DRUD1-58343, DRUD1-58304 |
| When runCommand is run in a container where containerExec is disabled, the command fails and returns BAD_PARAM. | DRUD1-58469 |
| On the containerInit script edit page, there should not be a disable action. | DRUD1-58470 |
| In consolidation of the inferred model, 'zombie' discovery runs are shown. | DRUD1-54355, DRUD1-54029, DRUD1-54322, DRUD1-54488, DRUD1-54591, DRUD1-54868, DRUD1-54896, DRUD1-58300, DRUD1-58419, DRUD1-58485, DRUD1-58606, DRUD1-58676, DRUD1-58875, DRUD1-58879 |
| The datastore holds global read lock for the whole time of missed write replaying, blocking other cluster activity. | DRUD1-58554, DRUD1-15367, DRUD1-58733, SSR-24999 |
| The model could stall in certain scenarios. | DRUD1-51174, DRUD1-58739, DRUD1-54668, DRUD1-51176, DRUD1-54165, SSR-23407 |
February 2026
This is the release of BMC Helix Discovery version 26.1.01.
This version of BMC Helix Discovery introduces the following enhancements:
Add Custom certificate authorities to the system. In environments where certificates are valid only within your organization, public certificate validation fails because the certificate chain does not link to public root certificates, even though the certificate itself is trusted internally. Custom certificate authorities can be managed by using the /vault/certificates endpoints in the BMC Discovery Outpost REST API.
Custom certificate authorities are only used by credential brokers.
- Credential brokers can use Custom certificate authorities. They are installed in the BMC Discovery Outpost.
The 26.1.01 version of BMC Helix Discovery applies the Technology Knowledge Update TKU 2026-Mar-1 and resolves the following defects:
| Description | Defect ID |
|---|---|
| Deferred model updates do not activate inferred sync for their tracker. | DRUD1-54825, DRUD1-58061, DRUD1-58345, DRUD1-54868, DRUD1-54241 |
| Oracle discovery from an outpost fail after the first error java.sql.SQLSyntaxErrorException: ORA-00942. | DRUD1-53980, DRUD1-53824 |
| In use, nslookup and handles accumulate and the BMC Discovery Outpost can be unreachable. | DRUD1-58093, DRUD1-54897 |
| Discovery of Cisco IMC fails when using an API connection. | DRUD1-58108, DRUD1-58069 |
| Failures related to libsnmp++. | DRUD1-58059, DRUD1-53701, DRUD1-54806, DRUD1-58176, DRUD1-58218, DRUD1-54594, DRUD1-54777, DRUD1-54815, DRUD1-58113, DRUD1-58607 |
| Uploading an invalid XML report prevents the appserver service from running. | DRUD1-53433, DRUD1-53377 |
| When saving a blueprint model, the following error is displayed in the UI: Error Failed to save service(s) 'uiSelector0__suffix___0' not provided. | DRUD1-58179, DRUD1-58380, DRUD1-58381, DRUD1-51087, DRUD1-54828 |
| If the reasoning service restarts while a snapshot cloud scan is in progress, clicking on Manage > Discovery can lead to a Technical Difficulty error page. | DRUD1-58338 |
| The documentation for the BeyondTrust Password Safe credential broker does not cover replacement markers. | DRUD1-43592 |
| TimeSeries and Chart reports do not reflect changes when uploaded through Custom Reports Management UI. | DRUD1-51972, DRUD1-51962 |
| "Refine by keywords" does not filter Destroyed nodes. | DRUD1-54893, DRUD1-54882 |
| Remedyforce CMDB Sync connection test always fails for the non-production instance. | DRUD1-52397, DRUD1-52313 |
| The ECA engine can stop working. This has been observed during consolidation of inferred data. | DRUD1-51025, DRUD1-51473, DRUD1-51207, DRUD1-51208, DRUD1-58145, DRUD1-58146, DRUD1-51003, DRUD1-58051, DRUD1-51231, DRUD1-51547, DRUD1-54498 |
| There is a discrepancy in the Physical Servers Count in Discovery dashboard. | DRUD1-46823 |
| Trying to view the BMC Discovery Outpost copyright page results in a 500 Internal Server Error. | DRUD1-58392, DRUD1-58247, DRUD1-54343 |
| The memory usage increases on the BMC Discovery Outpost after each cloud scans and it is not released. | DRUD1-58183, DRUD1-54749, DRUD1-58216, DRUD1-54775, DRUD1-58099 |
January 2026
This is the release of BMC Helix Discovery version 26.1.00.
This version of BMC Helix Discovery introduces the following enhancements:
- Mainframe discovery by using an API provider. BMC Helix Discovery discovers the same information as the existing NVBAPI, it is a new access method to the BMC Mainframe z/OS Agent. The API provider method can use a client certificate rather than a username/password combination, though the username/password combination is still supported.
- Where hosts were discovered where a Discovery Condition is triggered, the Host page in the UI provides a banner stating that the Discovery Condition was used.
The 26.1.00 version of BMC Helix Discovery applies the Technology Knowledge Update TKU 2026-Feb-1 and resolves the following defects:
| Description | Defect ID |
|---|---|
| Search queries issues by a saved search are not audited. | DRUD1-52377 |
| Scan OCI Host fails with "Connection timeout" message. | DRUD1-53561 |
| The documentation should have a warning for Credential Guard use in Windows discovery. | DRUD1-53885 |
| Container RuntimeEnvironments are no longer reported when searching. | DRUD1-53887 |
| Custom report charts are not rendered, and errors are reported in the browser console. | DRUD1-54032 |
| The documentation for "Windows Discovery using Powershell" incorrectly mentions availability of the default configuration file required for JEA based windows discovery in UI under Manage > Discovery Tools. | DRUD1-54095 |
| The list of discovery methods for VMware in the UI is incomplete. | DRUD1-54238 |
| Scanning some Management Controllers is failing with "Committing changes failed" ECA error. | DRUD1-54597 |
| Damaged Pattern node relationship information can prevent pattern module activation. | DRUD1-54661 |
| The Outpost can consume excessive memory when scanning Microsoft Azure. | DRUD1-54749 |
| Mismatched patterns at the sender and receiver may result in missing inferred synchronization data. | DRUD1-54752 |
| VMware guest Scanning only attempts the first credentials in the list. | DRUD1-54804 |
Generally available 2025 enhancements
The following updates have been released in 2025.
December 2025
This is the release of BMC Helix Discovery version 25.4.02.
This version of BMC Helix Discovery introduces enhancements to synchronization to ServiceNow CMDB. The following items are synchronized to ServiceNow CMDB:
- End-of-Life data
- Tags
Additionally, data can be synchronized to a table in ServiceNow CMDB. For more information on the enhancements to synchronization to ServiceNow CMDB, see the following: Preparing ServiceNow CMDB for synchronization and ServiceNow Mapping for multiple device types.
The 25.4.02 version of BMC Helix Discovery applies the Technology Knowledge Update TKU 2026-Jan-2 and resolves the following defects:
| Description | Defect ID |
|---|---|
| The documentation for supported CMDB versions was improved. | DRUD1-42796 |
| Importing model definitions created by using the blueprint template to a different environment fails with the error "Failed to import model definition ". | DRUD1-54157 |
| SSL certificates should be synchronized to ServiceNow CMDB. | DRUD1-38117 |
November 2025
This is the release of BMC Helix Discovery version 25.4.01.
This version of BMC Helix Discovery introduces the following capabilities:
- Download a default Windows JEA Role Configuration file from the BMC Helix Discovery UI. By using JEA in BMC Helix Discovery, you can discover Windows hosts without providing credentials with full administrator access. To configure JEA effectively, you must add all of the cmdlets and executables that you want to enable to an allow list. The default configuration covers basic Host discovery, that is, those in the platform scripts. Commands run by patterns are not covered and must be added as required. See Discovering Windows hosts by using PowerShell for more information.
- Support for Boolean and none values in parameterized queries in the visual query builder. See Using the visual query builder and Visual query builder tools.
The 25.4.01 version of BMC Helix Discovery applies the Technology Knowledge Update TKU 2025-Dec-1 and resolves the following defects:
| Description | Defect ID |
|---|---|
| The BMC Discovery Outpost might require rebooting when nslookup processes are not removed. | DRUD1-53962 |
| The Technical difficulties page is shown when viewing Network device interface tables. | DRUD1-53961 |
| The Home page and Modeling home page can fail to load when very large numbers of old ActivityRecords are present in the system. | DRUD1-53902 |
| The export/import of the Business service model definition does not include inter-service (parent-child) relationships. | DRUD1-53843 |
| When Docker-managed SoftwareInstances with different versions are created, they are represented as a single SI. | DRUD1-53778 |
| Stable Software Instance creation for Docker Swarm is not being modeled correctly. | DRUD1-53776 |
| The documentation did not clearly state that CMDB Resync does not remove manually created CIs. | DRUD1-53446 |
| The Blueprint edit button is not always enabled when required. | DRUD1-51455 |
| There are SSH/KRB Failures in the BMC Discovery Outpost. | DRUD1-51405 |
| The CMDB Synchronization root node docs require updating. | DRUD1-51055 |
| Password "special characters" are not documented and do not include all Latin ASCII Punctuation and Symbols. | DRUD1-50217 |
| Firewall ports documentation was incomplete. | DRUD1-47502 |
| The DiscoveryAccess page incorrectly stated that getMACAddresses is mandatory for Host creation. | DRUD1-24596 |
October 2025
This is the release of BMC Helix Discovery version 25.4.00.
This version of BMC Helix Discovery introduces the following capabilities:
- Discovery of Windows hosts by using PowerShell credentials does not rely on NTLM. Select Kerberos to specify Kerberos authentication. Kerberos authentication requires either that the BMC Discovery Outpost's host is in the same domain as the target or that a DNS lookup of the target's IP address returns the correct hostname, and that the username is in the form username@dns.domain. For more information, see Adding credentials.
- Data sources support using https proxies. To add an https proxy, specify the proxy URL and port. For more information, see Adding data sources.
The 25.4.00 version of BMC Helix Discovery applies the Technology Knowledge Update TKU 2025-Nov-1.
The 25.4.00 version of BMC Helix Discovery also resolves the following defects:
| Description | Defect ID |
|---|---|
| Installing the CyberArk integration (AIM 14.2) on the Outpost results in the error: "CyberArk SDK file not found" on Outpost | DRUD1-53745 |
| The UI and documentation require a warning stating that renaming Scope is not supported. | DRUD1-52999 |
| Provide more details in the documentation on the query function: sorted(). | DRUD1-52405 |
| Discovery Email sending fails with name, email or subject containing non-ASCII characters. | DRUD1-50739 |
| The "Running the BMC Discovery Outpost under a gMSA account" requires clarification. | DRUD1-50191 |
| Supported versions discrepancy between CMDB Sync pages and version compatibility matrix. | DRUD1-47120 |
September 2025
This is the release of BMC Helix Discovery version 25.3.02.
This version of BMC Helix Discovery introduces the following capabilities:
- Improves the display of BMC Discovery Outposts in the Home page. When more that three BMC Discovery Outposts are connected, three are displayed, and a Show all link is provided.
- If an Outpost is disabled, any credentials held by that Outpost are not available, and its entry is dimmed. See Configuring credentials for more information.
The 25.3.02 version of BMC Helix Discovery applies the Technology Knowledge Update TKU 2025-Oct-1.
See the TKU July for more information about the TKU schedule change.
The 25.3.02 version of BMC Helix Discovery also resolves the following defects:
| Description | Defect ID |
|---|---|
| Scan of the HP iLO6 fails with Error (Unable to get the deviceInfo: ExecutionFailure). | DRUD1-53455 |
| A subset of nodes returned in Blueprints UI. | DRUD1-53173 |
| Bulk Windows device scan by using PowerShell results in "Bad HTTP response returned from the server. Code: 400, Content" | DRUD1-52188 |
| The "getProcessList" method fails with the error "unexpected output format" on Windows servers. | DRUD1-51585 |
| Mainframe CMDB Sync mapping does not sync Serial number. | DRUD1-47129 |
August 2025
This is the release of BMC Helix Discovery version 25.3.01.
This version of BMC Helix Discovery introduces the following capabilities:
- Adds constants to the search language. See Using the Query Language for more information. The following constants are available:
- true
- false
- none
- Provides filters to identify and avoid populating UUID, Serial, and HostID with invalid values. See the Device Identification section in Configuring discovery settings for more information.
- When viewing a blueprint model definition (rules_template), clicking Run as Query shows the Visual Query Builder view of the template.
The 25.3.01 version of BMC Helix Discovery retains the Technology Knowledge Update TKU 2025-Jul-1. See the TKU July for more information about the TKU schedule change.
The 25.3.01 version of BMC Helix Discovery also resolves the following defects:
| Description | Defect ID |
|---|---|
| Invalid code is generated for TPL with dangerous loop usage. | DRUD1-52926 |
| Empty rules-based models cause multiple ActivityRecords. | DRUD1-52689 |
| Search function injecting extra '/ui' in URL path after inactivity resulting in 404 error. | DRUD1-52350 |
| A datasource connection should try to reopen connection when a close is detected. | DRUD1-49593 |
| The role ARN for AWS (and Alibaba), the Subscription for Azure, and the project for GCP can be truncated. | DRUD1-43374 |
July 2025
This is the release of BMC Helix Discovery version 25.3.00.
The 25.3.00 version of BMC Helix Discovery applies the Technology Knowledge Update TKU 2025-Jul-1.
This version of BMC Helix Discovery also made improvements to our internal infrastructure and management tools and resolves the following defects:
| Description | Defect ID |
|---|---|
| ECA Error on rule evaluate_model_definition due to: "Group with key 'b'\xad\xf9\xd5A\x18f&\xb6\xf1\xc6\xbd\xb1\x8b\x98x91}'' already exists". | DRUD1-52623 |
| Accessing Kerberos TGT from ccache can take a long time. | DRUD1-52616 |
| High CPU consumption in the Outpost might occur during a GCP scan. | DRUD1-52475 |
| VMware Guest Credentials do not work with Delinea (Thycotic) Secret Server. | DRUD1-52470 |
| When scanning AWS, assuming roles can be slow. | DRUD1-52461 |
| You cannot mass destroy NetworkService nodes. | DRUD1-52163 |
| The required API permission is missing in the Importing topology data documentation. | DRUD1-52140 |
June 2025
This is the release of BMC Helix Discovery version 25.2.02.
This version of BMC Helix Discovery introduces the following capabilities:
Deep container discovery
BMC Helix Discoveryprovides detailed discovery of software running inside containers. A scan of a container in the data center has two parts: SSH access and API access. SSH access discovers running processes, whether they are containers, running in containers, or one of the levels of orchestration or runtime processes. If the process is identified as a container, and it is simply running on a host without orchestration software, its discovery continues by using SSH. Patterns determine the version of the software running in the container.
The 25.2.02 version also applies the Technology Knowledge Update TKU 2025-Jun-1 and resolves the following defects:
| Description | Defect ID |
|---|---|
| Unable to generate HTTPS key in the UI where the server name is only numbers. | DRUD1-52358 |
| Netapp Storage System with Model "NetApp Cluster" shows error. | DRUD1-52289 |
| Restart causes 504s on chart channel pages. | DRUD1-52213 |
| Some OCI SSH targets are not scanning. | DRUD1-51887 |
| The "Use last login method" does not work for Windows Server. | DRUD1-51679 |
| The BMC Discovery Outpost log contains ssl.SSLEOFError: errors. | DRUD1-51496 |
May 2025
This is the release of BMC Helix Discovery version 25.2.01.
This version of BMC Helix Discovery introduces the following capabilities:
- BGP network route discovery. BMC Helix Discovery discovers IP links between network devices by using BGP IP routing information, and discovers site-to-site connectivity using ISP AS path information. It supports iBGP and eBGP. For further information, see IP Connectivity using BGP data.
- A new node kind, Certificate, representing Certificates discovered on Hosts, Load Balancer Services, MF Parts, Network Devices, Software Instances, Cloud Services, Network Services, and Management Controllers.
The 25.2.01 version also applies the Technology Knowledge Update TKU 2025-May-1 and resolves the following defects:
| Description | Defect ID |
|---|---|
| A pattern fails with the following message: Problem setting pattern state: cannot access local variable 'a' where it is not associated with a value. | DRUD1-52025 |
| The TPL code generated from some CAM model does not compile. | DRUD1-51960 |
April 2025
This is the release of BMC Helix Discovery version 25.2.
This version of BMC Helix Discovery introduces the following capabilities:
- Discover hosts using Oracle Cloud Infrastructure bastion. BMC Helix Discovery accesses the bastion with the OCI credential, and the bastion creates a managed SSH session to Linux hosts without requiring further credentials. For more information, see Discovering hosts in OCI by using OCI bastion.
- Trigger run types. A ‘trigger’ discovery run allows you to create a discovery run that executes a pattern without performing any discovery. The pattern can be a simple pattern, or one written to access a defined data source type. For more information, see Creating import triggers and Performing a discovery run.
- OAuth2 authentication using client_id and client_secret no longer requires user name and password. See Discovery restful functions for more information.
- The OAuth2 authentication method is a client credentials grant or user credentials grant, as described on the IETF Tools website.
- User credentials grant is used if a username and password is specified in the credential or data source.
- Client credentials grant does not support a username, but requires a Client ID and secret.
- The OAuth2 authentication method is a client credentials grant or user credentials grant, as described on the IETF Tools website.
The 25.2 version also applies the Technology Knowledge Update TKU 2025-Apr-1 and resolves the following defects:
| Description | Defect ID |
|---|---|
| Request to document that the short_name is used as the label in visualization. | DRUD1-31741 |
| Cloud Database nodes are not synchronized to ServiceNow CMDB. | DRUD1-42396 |
| License use for BMC Helix Operations Management and Helix Intelligent Integrations created hosts is unclear. The licensing page in the UI, and the documentation has been updated. | DRUD1-46557 |
| The BMC Helix Discovery Outpost Credential Import button can be clicked repeatedly leading to duplicate credentials. | DRUD1-50580 |
| The option to Compress a currently active Log file should be removed. | DRUD1-50704 |
| Username and password should not be mandatory for data sources with oauth2. | DRUD1-50787 |
| Online compaction on multi-generational Datastore should not run when only one read-only generation exists. | DRUD1-50845 |
| CMDB Services Sync does not start when the vault requires a passphrase. | DRUD1-51020 |
| Rarely, the ECA engines might encounter a problem and consume excessive resources. This has been fixed. | DRUD1-51025 |
| A visual query that uses the before condition does not return the expected output. | DRUD1-51094 |
| Taxonomy modification for visibility of SoftwareInstance ElementUsingFile relationship in the UI. | DRUD1-51135 |
| CMDB Services Sync might remove relationships in BMC Helix Discovery while they are present in the CMDB. | DRUD1-51175 |
| A traceback is seen when viewing some StorageSystems. | DRUD1-51272 |
| Discovery by using the vCenter API does not return network interface information. | DRUD1-51282 |
| Allow fetching token for REST API with OAuth2 authentication using basic authentication header. | DRUD1-51320 |
| Queries that use parameters that you save in "Favorite Queries" fail with an "Invalid conditions" message. | DRUD1-51518 |
| The Search Query function friendly_duration does not work as expected. See [Query Language Functions] for updated documentation. | DRUD1-51521 |
| Receiver restart during a Consolidation of inferred data resync caused all synced data to be destroyed on the receiver. | DRUD1-51661 |
| When targets that are not expecting a password are scanned by using SSH with a username/password combination, a traceback is logged. | DRUD1-51900 |
March 2025
There was no BMC Helix Discovery release in March 2025.
February 2025
This is the release of BMC Helix Discovery version 25.1.01.
This version of BMC Helix Discovery introduces the following capabilities:
- Visualizations allow you to view their state at earlier dates. For more information see Viewing a visualization at earlier points in its history.
- Results from the discovery of additional endpoints are shown on the requesting DiscoveryAccess. For more information, see the DiscoveryAccess page.
- The Directly Discovered Data removal statistics page shows how the automatic aging of DDD is keeping up with the creation of DDD. For more information, see Viewing statistics for Directly Discovered Data removal.
The 25.1.01 version also applies the Technology Knowledge Update TKU 2025-Feb-2 TKU to DEV and PROD instances and resolves the following defects:
Description | Defect ID |
|---|---|
Discovery scripts for some platforms (such as aix.sh) do not contain the getHBAInfo method. | DRUD1-50714, |
Setting record mode incorrectly required the security/options/write permission. | DRUD1-50539 |
Attribute retrieval for a large set of nodes can take a very long time. | DRUD1-50889, |
There is no way to purge logs in the BMC Discovery Outpost. | DRUD1-50596 |
"Type" for "Wireless LAN Controller" and "Access Point" is missing in CMDB sync for ServiceNow CMDB. | DRUD1-38937 |
CMDB Services Sync can remove relationships in BMC Discovery although they are still present in the BMC CMDB. | DRUD1-51175, |
Consolidation of inferred data occasionally stops synchronizing. | DRUD1-51003, |
Windows 2025 Server hosts are classified as a "Windows 10 Desktop" when discovered from the BMC Discovery Outpost. | DRUD1-51019 |
The following security related issues have also been fixed:
- DRUD1-50944
- DRUD1-50942
January 2025
This is the relase of BMC Helix Discovery version 25.1.
This version of BMC Helix Discovery introduces the following new capabilities:
- Support for OpenSSH and ECDSA SSH keypairs for target scanning.
BMC Helix Discovery supports RSA2, DSA, ECDSA, and ED25519 keys in PEM format, generated with OpenSSH or OpenSSL. For hosts that only support SSH v1, you must use credentials for authentication. - Support for the BMC Discovery Outpost using an HTTPS proxy.
- Add related nodes to a visual query quickly without applying and adding each individual node.
The 25.1 version also applies the Technology-Knowledge-Update-TKU-2025-Jan-1 TKU to DEV and PROD instances and resolves the following defects:
Description | Defect ID |
|---|---|
Attribute retrieval for a large set of nodes can take a very long time. | DRUD1-50893, |
VMware guest scanning leaves PowerShell sessions running after discovery has been completed. | DRUD1-50693, |
Discovery of OpenVMS by using the BMC Discovery Outpost and SSH fails. | DRUD1-50574, |
PowerShell GetPackage list fails when package names contain control or special characters. | DRUD1-50499, |
Mainframe Discovery by using the latest BMC Discovery Outpost fails. | DRUD1-50437, |
The vCenter heuristic does not complete, and the scan times out. | DRUD1-50407, |
SQL queries of MySQL and PostgreSQL can fail reporting NoAccessMethod. | DRUD1-50154 |
Endpoint scans might finish, resulting in an ExecutionFailure error message. | DRUD1-50002, |
The BMC Discovery Outpost can occasionally cause DiscoveryAccess timeouts and slow scanning. | DRUD1-49943, |
Pie charts in a chart channel do not display when their name contains spaces. | DRUD1-49910 |
Custom report file names are truncated after the first period character. | DRUD1-49875 |
PowerShell reports 'Too many TCP connections (Bound state). | DRUD1-49701, |
Sometimes, a DiscoveredCommandResult.result contains unexpected characters. | DRUD1-49492, |
Using a generic webapi credential occasionally results in an "AssertionError: Credential doesn't support webapi sessions” exception. | DRUD1-49037, |
The model service does not start when using a custom report with custom attributes of table type. | DRUD1-40112 |
Generally available 2024 enhancements
The following updates were made during 2024.
December 2024
This is the release of BMC Helix Discovery version 24.4.02.
The 24.4.02 version applies the Technology-Knowledge-Update-TKU-2024-Dec-1 TKU to DEV and PROD instances.
Description | Defect ID |
|---|---|
Attribute retrieval for a large set of nodes can take a very long time. | DRUD1-50893, DRUD1-50889 |
VMware guest scanning leaves PowerShell sessions running after discovery has been completed. | DRUD1-50693, DRUD1-50801 |
Discovery of OpenVMS by using SSH and the BMC Discovery Outpost fails. | DRUD1-50574, DRUD1-50558 |
PowerShell GetPackage list fails when package names contain *** non English *** characters. | DRUD1-50499, DRUD1-50419 |
Mainframe Discovery by using the latest BMC Discovery Outpost fails. | DRUD1-50437, DRUD1-50669, DRUD1-49329 |
The vCenter heuristic does not complete and the scan times out. | DRUD1-50407, DRUD1-49599, DRUD1-49969, DRUD1-50391, DRUD1-50457 |
SQL queries of MySQL/Postgresql might fail and report the error NoAccessMethod. | DRUD1-50154 |
Endpoint scans might finish and report the error ExecutionFailure. | DRUD1-50002, DRUD1-50683, DRUD1-49990, DRUD1-49955 |
The BMC Discovery Outpost can create too many worker processes, which consume too many resources, resulting in DiscoveryAccess timeouts and slow scanning. | DRUD1-49943, DRUD1-49460, DRUD1-49385 |
A pie chart in a chart channel fails to display when its name contains spaces. | DRUD1-49910 |
Custom report file names are truncated after the first period character. | DRUD1-49875 |
"Too many TCP connections (Bound state)" reported by PowerShell. | DRUD1-49701, DRUD1-49683 |
Sometimes, the DiscoveredCommandResult.result contains unexpected characters. | DRUD1-49492, DRUD1-49808, DRUD1-50672, DRDC1-24140, DRUD1-50314 |
"AssertionError: Credential doesn't support webapi sessions” relate to trying a generic webapi credential an exception is observed. | DRUD1-49037, DRDC1-24731, DRUD1-49026, DRUD1-49931, DRUD1-50144, DRUD1-48860, DRUD1-49385 |
The model service can fail to start when using a custom report with custom attributes of table type. | DRUD1-40112 |
November 2024
This is the release of BMC Helix Discovery version 24.4.01.
The 24.4.01 version also applies the Technology-Knowledge-Update-TKU-2024-Nov-1 TKU to DEV and PROD instances and resolves the following defects:
Description | Defect ID |
|---|---|
In the Service and Application modeling UI, the View History option is missing for Model Definition nodes. | DRUD1-47996 |
When you when try to Export Model definitions, the export fails with an "Error 504 (Gateway timeout)" message. | DRUD1-47718 |
Testing a BMC Remedy ITSM Authentication data source URL using an FQDN causes an error: "URL must contain an IP address instead of DNS name to test the credential." | DRUD1-41901 |
Clicking Save in the Query Constructor panel does not close the window. | DRUD1-49859 |
Modifying the variables in a blueprint affects Services that are created from the blueprint. Scans result in ECA Errors of the form: Error on rule evaluate_model_definition due to: Parameter 'n___1type_0' not provided. | DRUD1-49573 |
"WARNING: Error parsing" when the name of a custom channel matches the name of a custom report. | DRUD1-47694 |
A visualization of an application model does not complete loading, and its model definition does not show the option to republish. | DRUD1-41825 |
The Blueprint preview configuration does not show the list of nodes from response. | DRUD1-50291 |
Where the parent of a child service is changed, notification not received from the child service that its parent changed. | DRUD1-47179 |
A data completeness warning was raised for multiple locations. Locations with different semantics like Region, Country, DC-Room, and so on are now permitted. | DRUD1-47711 |
October 2024
This is the release of BMC Helix Discovery version 24.4.00.
This version of BMC Helix Discovery introduces the ability to consolidate inferred data from an on-premises BMC Discovery appliance, or another BMC Helix Discovery SaaS instance. Consolidation of the inferred model is used primarily to synchronize data from existing on-premises BMC Discovery appliances into the BMC Helix ecosystem, where other products, such as BMC Helix AIOPs, can use BMC Discovery's rich data.
For more information, see Consolidation.
This version of BMC Helix Discovery applies the Technology-Knowledge-Update-TKU-2024-Oct-1 TKU.
September 2024
This is the release of BMC Helix Discovery version 24.3.02.
This version of BMC Helix Discovery applies the Technology-Knowledge-Update-TKU-2024-Sep-1 TKU to DEV and PROD instances.
August 2024
This is the release of BMC Helix Discovery version 24.3.01.
This version of BMC Helix Discovery provides the following enhancements:
- Automatic discovery of cloud-based Kubernetes clusters occurs by default when you scan your supported cloud services. When BMC Discovery finds a Kubernetes cluster, it creates an automatic scan using a Kubernetes token obtained from the cloud provider. Automatic scanning of Kubernetes clusters can be disabled (Automatically scan Kubernetes clusters) for each scan. No additional credentials are required. The API token is generated depending on your existing privileges. See Discovering-Kubernetes-clusters and Kubernetes (BMC Discovery Content Reference) for more information.
- Select and export any combination of credentials from the credentials page, in addition to exporting single credentials or the entire credentials vault. See Exporting-and-importing-the-credential-vault for more information.
The 24.3.01 version also applies the Technology-Knowledge-Update-TKU-2024-Aug-1 TKU to DEV and PROD instances and resolves the following defects:
Description | Defect ID |
|---|---|
Models created by using Service Blueprints and adding information from tags are empty. | DRUD1-49014 |
Error when saving Blueprint Service Definition that includes regex. | DRUD1-48715 |
July 2024
This is the release of BMC Helix Discovery version 24.3.00.
This version of BMC Helix Discovery provides the following enhancements:
- Use SAML based SSO authentication for the discovery of VMware guest hosts.
- An admin user can delete a saved query shared by another user.
- The definitions for credentials in the REST API show only the common attributes and are easier to use.
- TPL templates are provided so that you can write sync mapping extensions for Azure services.
- The Visual Query Builder supports queries with parameters specified when you run the query.
- To avoid missing devices that listen on UDP only, you can skip pre-scanning when configuring a scan.
- Export the entire credential vault, individual credentials, or the credentials you have selected for display in the UI.
The 24.3 version also applies the Technology Knowledge Update TKU 2024-Jul-1 TKU to DEV and PROD instances and resolves the following defects:
Description | Defect ID |
|---|---|
Guest and ESX hosts are missing when vCenter is scanned with the option VMware Guest Scanning enabled. | DRUD1-47940 |
When you discover databases, memory consumption increases with the size of the database cluster. | DRUD1-42656 |
ServiceNow CMDB sync connection that times out shows an incorrect error message. | DRUD1-43073 |
Expired Kerberos credentials might block subsequent scans with 30 min timeouts. | DRUD1-47007 |
When a Host node is synced twice, the resulting CI might receive unexpected updates. | DRUD1-48512 |
A RecursionError is reported when processing CMDB filters. | DRUD1-46967 |
Windows hostnames discovered by using PowerShell are truncated. | DRUD1-47963 |
A duplicate host might be created when two sources have conflicting MAC address information for a Linux host. | DRUD1-48254 |
During CMDB sync, a custom CMDB sync pattern fails with AttributeError: module 'cmdb_sync.functions' has no attribute 'hasSubword'. | DRUD1-48712 |
When scanning AWS, SSM connections do not respect the TLS certification check setting in the credential. | DRUD1-46701 |
Destruction of nodes in a model causes a full update of the model, even if it is in the review-suggested state. | DRUD1-48261 |
June 2024
This is the release of BMC Helix Discovery version 24.2.02.
This version applies the Technology Knowledge Update TKU 2024-Jun-1 and resolves the following defects:
Description | Defect ID |
|---|---|
Added the ability in the BMC Discovery Outpost to configure the number of worker processes in the queue group. | DRUD1-46829 |
Updated the BMC Discovery Outpost thread pool size to adjust for the number of worker processes. | DRUD1-47263 |
Discovery of the HP iLO product fails stating there is NoAccess. | DRUD1-48094 |
DataSource discovery by using the BMC Discovery Outpost. | DRUD1-48133 |
May 2024
This is the release of BMC Helix Discovery version 24.2.01.
This version applies the Technology Knowledge Update TKU 2024-May-1.
April 2024
This is the release of BMC Helix Discovery version 24.2.00.
This version applies the Technology Knowledge Update TKU 2024-Apr-1 and includes the following enhancements:
- Discover and display additional attributes for TLS Certificate Discovery.
- The BMC Discovery Outpost only uses 'Modern' ciphers as defined by Mozilla. See this article on the Mozilla website.
The update also resolves the following defects:
Description | Defect ID |
|---|---|
Content Security Policy contained in BMC Helix Discovery does not allow Gainsight-required artifacts to be displayed. | DRUD1-47014 , DRUD1-47216 |
The licensing page shows "Not Installed Storage Discovery" while Storage TKU is installed. | DRUD1-47068 , DRUD1-46828 |
Powershell discovery failure message is not helpful. | DRUD1-43886 , DRUD1-46439 |
Outpost SSH workers remain after the scan is finished. | DRUD1-43058 , DRUD1-43920 |
SSM Setting on a scheduled Discovery Run cannot be changed to Disabled. | DRUD1-43392, DRUD1-43928, DRUD1-46862, DRUD1-43057 |
Contributor:Inference relationship should be deleted or updated with new Package version. | DRUD1-40477 |
The dashboard does not uncheck the checkbox for a custom channel in the UI. | DRUD1-40019 |
March 2024
This is the release of BMC Helix Discovery version 24.1.02.
This release applies the Technology Knowledge Update TKU 2024-Mar-1.
The update includes the following new features:
- Enhanced pattern compilation and execution:
- Reduced compile times
- Improved compile-time errors and warnings
- Runtime ECA Errors now include a traceback of the TPL calls
- The changes fix or improve some of the existing behaviors in TPL. See What-s-new-in-TPL for more information.
- Pattern management enhancements:
- Deactivated patterns stay deactivated when a new TKU is applied.
- Provide a direct link to newly imported pattern modules after upload.
- Securely register BMC Discovery Outposts by using the Outpost and BMC Helix Discovery REST APIs. See Authenticating-with-the-Outpost-REST-API for more information.
- Securely register Outposts using the REST APIs
- Exchange tokens by calling APIs on both Outpost and BMC Helix Discovery.
- Filter on relationship attributes in the visual query builder.
- Produce compact JSON output from the REST API.
The update also resolves the following defects:
Description | Defect ID |
|---|---|
The licensing page displays "Not Installed Storage Discovery" although the Storage TKU is installed | DRUD1-46828 |
The taxonomy does not contain the relationship (GenericElement) | DRUD1-46696 |
Windows UBR (Update Build Revision) Registry Key is not discovered when using WMI. | DRUD1-43532 |
The TPL mail.send documentation incorrectly states that SMTP is required on BMC Helix Discovery instances. | DRUD1-41529 |
February 2024
This is the release of BMC Helix Discovery version 24.1.01.
This release applies the Technology-Knowledge-Update-TKU-2024-Feb-1.
The update also resolves the following defects:
Description | Defect ID |
|---|---|
New documentation is provided for the BMC Helix Discovery ServiceStatus page. | DRUD1-42635 |
Documentation for SNMP discovery has been updated to clarify that login attempts with SNMP queries are used only if:
| DRUD1-42455 |
January 2024
This is the release of BMC Helix Discovery version 24.1.00.
This release introduces the ability to automatically synchronize services from BMC Helix CMDB into BMC Helix Discovery.
The Technology-Knowledge-Update-TKU-2024-Jan-1 was applied.
The update also resolves the following defects:
Description | Defect ID |
|---|---|
Discovering Citrix NetScaler devices by using the REST API fails after November TKU. | DRUD1-43492 |
In certain rare upgrade failure circumstances the vault could become inaccessible. This has been corrected. | DRUD1-43484 |
BMC Discovery Outpost connection through proxy does not work until name resolution is available from the BMC Discovery Outpost. | DRUD1-43456 |
External events are not sent by consolidation. | DRUD1-43342 |
When the BMC Discovery Outpost released with the November TKU is installed on a FIPS enabled host, if it is not installed in the C:\ drive, the installation/upgrade does not place the fips.conf file correctly. | DRUD1-43256 |
HTML bold font code is visible when searching for ModelDefinitions. | DRUD1-43119 |
Since outpost 130.86.7818.867818, connection to the Hashicorp credential vault fails. | DRUD1-42843 |
tw_svc_cluster_manager.log showing security.api: WARNING: User 'xxxxxx' does not have permission for operation 'cmdb_sync'. | DRUD1-42587 |
The REST API does not honor maintenance mode. | DRUD1-42324 |
A connection error is displayed in the UI on CMDB timeouts. | DRUD1-41552 |
You cannot bulk delete Recognition Rules, or sort rules in the UI according to Status. | DRUD1-41491 |
Generally available 2023 enhancements
December 2023
This is the release of BMC Helix Discovery version 23.4.02.
This release introduces the Visual query builder which enables you to define queries using a visual representation of the nodes and relationships. You can filter using combinations of attributes, focus the results on any of the nodes, and specify columns from any of the related nodes to show in the results. See Using-the-visual-query-builder for more information.
The Technology-Knowledge-Update-TKU-2023-Dec-1 was applied.
The update also resolves the following defects:
Description | Defect ID |
|---|---|
For some AIX 7.1 targets, the getIPAddresses method fails with error "Unexpected Output format". | DRUD1-42906 |
Running a saved query fails and displays an error page. | DRUD1-43324 |
RunCommand fails with a 'Bad HTTP response returned from the server. Code: 400, Content:' error although the command result is visible and correct. | DRUD1-43072 |
SSH discovery is timing out for some Linux hosts. | DRUD1-42317 |
The ServiceNow dependencies for classes "cmdb_ci_logical_datacenter" and "cmdb_ci_resource_group" are undocumented. See ServiceNow-Mapping-for-Cloud for updated documentation. | DRUD1-35561 |
A lookahead in a regex does not work correctly in the regex.extract() TPL function. | DRUD1-42619 |
When syncing Microsoft Azure subscritions, cmdb_ci_azure_subscription object_id is fed with cloud region subscription_name instead of subscription_id. | DRUD1-40883 |
Outpost API Patch Credential Fails for AWS Credentials. | DRUD1-41040 |
ServiceNow syncmapping: sync of stacked devices is not working correctly. | DRUD1-32009 |
ServiceNow syncmapping: sync of Serial Number for cmdb_ci_lb class is not working correctly. | DRUD1-32010 |
ServiceNow syncmapping: sync of ip_version mapping for IP Address CI is incorrect. | DRUD1-31779 |
ServiceNow syncmapping: the ServiceNow.SoftwareInstance_cmdb_ci_appl syncmapping does not consider related pattern publishers to set manufacturer. | DRUD1-34794 |
ServiceNow syncmapping: the ServiceNow.NetworkDevice_Host_Linkage does not create Connects_to__Connected_by relationship for edge connectivity. | DRUD1-34817 |
ServiceNow syncmapping: for Linux hosts, the OS service pack is not synced to ServiceNow CMDB for Linux Hosts. | DRUD1-34886 |
November 2023
This is the release of BMC Helix Discovery version 23.4.01.
The Technology-Knowledge-Update-TKU-2023-Nov-1 was applied.
The update also resolves the following defects:
Description | Defect ID |
|---|---|
When Outposts or TKUs are updated, some Outposts were disconnected from the instance and must be updated manually. | DRUD1-40540 |
Cross-Services CI links were not exposed by 'topology/nodes' endpoint | DRUD1-40253 |
SAAM modeling: Following Management connections added large numbers of unwanted nodes to the model. The system no longer follows Management connections. | DRUD1-42057 |
Incorrectly formed .xml report files caused a Critical Exception. | DRUD1-42337 |
October 2023
This is the release of BMC Helix Discovery version 23.4.
The Technology-Knowledge-Update-TKU-2023-Oct-1 was applied.
The update also resolves the following defects:
Description | Defect ID |
|---|---|
Occasionally scans fail showing an SSH timeout error on hosts with non-English locales. | DRUD1-42317 |
A credential test failure in Thycotic credentials broker shows password in readable format. | DRUD1-42295 |
When editing and saving a CyberArk credential, the BMC Discovery UI shows a 502 Error - Service Temporarily Overloaded. | DRUD1-42129 |
September 2023
This is the release of BMC Helix Discovery version 23.3.02.
The Technology-Knowledge-Update-TKU-2023-Sep-1 was applied.
Description | Defect ID |
|---|---|
Cannot download a BMC Discovery Outpost through an HTTP proxy that has a backslash character '/' in its name. You can workaround this problem by using percent encoding for the backslash. See Downloading and installing a BMC Discovery Outpost for more information. | DRUD1-42216 |
The models API gives the state of a published model, including the published node's node ID. It should also include the published node's key. | DRUD1-42082 |
August 2023
This is the release of BMC Helix Discovery version 23.3.01.
The Technology-Knowledge-Update-TKU-2023-Aug-1 was applied.
July 2023
This is the release of BMC Helix Discovery version 23.3.
The update provides the following new enhancements:
- Discover hosts by using PowerShell and Windows Just Enough Administration (JEA).
- The Technology-Knowledge-Update-TKU-2023-Jul-1 was applied.
The update also resolves the following defects:
Description | Defect ID |
|---|---|
The discovery.getCertificate() TPL function should handle timeouts. | DRUD1-41408 |
Cannot generate a new key when the company name is too long. | DRUD1-40932 |
Cannot extract DOMAIN from Cyberark from an arbitrary attribute. See Using-CyberArk-credentials-for-discovery for more information. | DRUD1-40301 |
Unable to load credentials when the Enter key is used instead of the APPLY button. | DRUD1-39597 |
Windows package names can contain garbage characters. | DRUD1-38879 |
Windows could not start the Outpost Service because of timezone setting. | DRUD1-37180 |
ECA error:RuleError on rule reasoning_host_create_if_necessary. | DRUD1-31727 |
June 2023
This is the release of BMC Helix Discovery version 23.2.02.
The update provides the following new enhancements:
- View log files to help you diagnose problems with CMDB synchronization and writing patterns. You can watch logfiles in the BMC Helix Discovery UI, or you can download them to analyze on your local computer.
- The Technology-Knowledge-Update-TKU-2023-Jun-1 was applied.
The update also resolves the following defect:
Description | Defect ID |
|---|---|
Lifecycle reports enhancements (end of life data). | DRDC1-19678 |
May 2023
This is the release of BMC Helix Discovery version 23.2.01.
The update provides the following new enhancements:
- Use blueprint-based modeling to model services.
- Create and upload custom reports.
- Improvements in Start Anywhere Modeling:
- See combined software and infrastructure in a single view with Display > Focuses.
- Turn individual types of data on or off.
- Choose to see only incoming or only outgoing impacts.
- Mixed focuses.
- 'Directly Connected' focus allows you to see all the relationships of any node, and enables you to view imported graph data.
- 'Provenance' focus shows how data is inferred.
- See combined software and infrastructure in a single view with Display > Focuses.
- Improvements in visualizations, such as mixed focuses.
- Miscellaneous improvements:
- New and enhanced REST APIs, such as the ability to import topology information.
- Set default values for the Cloud Host Detection and VMWare Guest scanning options. These options set the defaults, the setting can still be specified for each Discovery run.
- The Technology-Knowledge-Update-TKU-2023-May-1 was applied.
The update also resolves the following defects:
Description | Defect ID |
|---|---|
The PRIV_LSHW privileged command was undocumented. | DRUD1-40899 |
SIs hosted on MFParts were not aging correctly. | DRUD1-40594 |
The last_discovered attribute should be set when a destroyed node is synced to ServiceNow CMDB. | DRUD1-40421 |
Recent run in Consolidator showing an error regarding "Outpost no longer registered". | DRUD1-40320 |
Discovery Run Errors on LPARs when Job Name is not reported. | DRUD1-40268 |
Powershell credential failures are not recorded in UI Session Result List. | DRUD1-39829 |
Deep discovery of VMware Guest Hosts feature performing unnecessary implicit scans of vCenter guest. | DRUD1-39805 |
Occasionally Amazon Web Services fails with ECA error, inference is None in InferenceKeyMaintainer.extract_keys(). | DRUD1-39802 |
Audit Log did not record login failure for user without correct permission. | DRUD1-39641 |
Unable to load credentials when Enter key is used instead of Apply button. | DRUD1-39597 |
Thycotic token expires after 20 minutes leading to scan failures. | DRUD1-39596 |
It is possible to get a URI Too Large Error. | DRUD1-39226 |
There is no detail within model Activity Record for some nodekinds. | DRUD1-38847 |
Database discovery attempts to use disabled credentials. | DRUD1-38387 |
Outpost login page unresponsive after vulnerability scan using Qualys. | DRUD1-37923 |
The Solaris serial is not discovered when the sneep utility is not in /opt/SUNWsneep/bin. | DRUD1-36534 |
CMDB resync may occasionally use excessive memory and the resync fail. | DRUD1-33393 |
DiscoveryRun node not able to attach to the DataSourceAccess node when a custom pattern triggers on the same DiscoveryRun node. | DRUD1-32538 |
Discovery pre-scan phase with Nmap, many non-existent unsupported devices were being created. | DRUD1-31351 |
Multiple processes running on the Proxy server are not being killed, resulting in the server requiring rebooting. | DRUD1-30304 |
April 2023
This is the release of BMC Helix Discovery version 23.2.
The update provides the following new enhancements:
- For users who access BMC Helix Discovery from BMC Helix Portal, in-app help is available from a floating widget at the bottom of every screen. Click the self-help widget to access a product tour, interactive guides, instructions for setting up and going live, and more.
- The Technology-Knowledge-Update-TKU-2023-Apr-1 was applied.
The update also resolves the following defects:
Description | Defect ID |
|---|---|
The BMC Discovery Outpost automatic update occasionally fails resulting in a BMC Discovery Outpost that can no longer connect to BMC Helix Discovery. The installation failure is not logged. | DRUD1-40329 |
After applying the Technology Knowledge Update TKU 2022-Dec-1 (December 2022) the BMC Discovery Outpost can no longer scan its own host. | DRUD1-39911 |
Discovery of OpenVMS using ssh from the BMC Discovery Outpost fails. | DRUD1-39902 |
A link is displayed to a report of CIs awaiting incremental resync, though the link is not documented. | DRUD1-23565 |
March 2023
This is the release of BMC Helix Discovery version 23.1.02.
The Technology Knowledge Update TKU 2023-Mar-1 was applied.
The update resolves the following defects:
Description | Defect ID |
|---|---|
The Host node view page shows a table of network interfaces and their IP addresses. If there are no NetworkInterfaces, no IP address information is shown. | DRUD1-40243 |
vCenter polling can stop if interesting events are infrequent. | DRUD1-40114 |
Explicit and Implicit scans of the same endpoint can cause odd failures. | DRUD1-40107 |
The CyberArk vault management page usability improvements. | DRUD1-39985 |
February 2023
This is the release of BMC Helix Discovery version 23.1.01.
The Technology-Knowledge-Update-TKU-2023-Feb-1 was applied.
January 2023
This is the release of BMC Helix Discovery version 23.1.
The update also provides the following new enhancements:
- Deep discovery of VMware Guest Hosts using vCenter APIs.
- You can disable cloud host detection for individual scans, avoiding an unnecessary step when you scan hosts that, for example are on a subnet that is not hosted in the cloud.
- The calls made to target systems have been further optimized. For example, irrelevant methods are skipped for targets and the DiscoveryAccess shows the reason as RequestSkipped.
- Installation of the BMC Discovery Outpost is supported on a Windows Server Core host.
- The Technology-Knowledge-Update-TKU-2023-Jan-1 was applied.
The update resolves the following defects:
Description | Defect ID |
|---|---|
The Model > Devices page shows error "Something went wrong!" | DRUD1-38936 |
The first credential test or scan after a Kerberos Outpost start fails. | DRUD1-36819 |
ServiceNow CMDB Sync. The isVirtual flag is not updated during sync due to case mismatch. | DRUD1-39294 |
The boot_time attribute on the HostInfo node is not described in the documentation or taxonomy. | DRUD1-39293 |
Boot Time for Windows hosts is not in the same date format when discovered using WMI and PowerShell. | DRUD1-39014 |
Clicking the scanner name on the consolidation configuration UI on the Consolidator reports "404 Error - File not found". | DRUD1-39250 |
Exporting Visualizations does not center on the printout. | DRUD1-39141 |
The Disk Monitoring email notifications do not provide the machine details. | DRUD1-39398 |
The documentation and Swagger UI require detailed options for /discovery/runs/scheduled, /discovery/runs/scheduled/{run_id} for get, patch and post actions. | DRUD1-39390 |
A duplicate HBA is created on clustered Windows hosts when using Remquery (hbacmd). | DRUD1-24146 |
Searching RootNodeKeyInfo can create queries too complex to run. | DRUD1-30120 |
Disk Monitoring can stop Discovery or shut down services even when Online Compaction is in progress. | DRUD1-39399 |
Insufficient error filtering leads to bogus Disk Drive model and vendor. | DRUD1-39393 |
Incorrect dns_domain reported for Windows servers when Win32_NetworkAdapterConfiguration returns multiple entries for dns_domain. | DRUD1-34157 |
Discovery Outpost proxy settings issue | DRUD1-39178 |
AWS Cloud Credentials show failure when you test them, but work during scanning. | DRUD1-37688 |
During ServiceNow sync, the AttributeError: 'NoneType' object has no attribute 'acquireLock' is logged. | DRUD1-33343 |