BMC Server Automation provisioning issues
Error messages when connecting to BMC Server Automation
The following error messages might be displayed when you run the pw blade test command to verify the connection between TrueSight Infrastructure Management and BMC Server Automation.
Message: Login failed: Connection timed out.
Explanation: It is possible that there is a connection error with the BMC Server Automation agent.
User Response: Perform the following tasks:
- Ensure that the BMC Server Automation Application Server process is started.
- Ensure that the BMC Server Automation agent is installed on the same host computer as the TrueSight Infrastructure Management Server.
- Ensure that the BMC Server Automation agent is licensed properly.
- Ensure that the BMC TrueSight Infrastructure Management Server process is started.
Message: Login failed: Connection refused
Explanation: It is possible that there is a connection error with the BMC Server Automation agent.
User Response: Ensure that the BMC Server Automation Application Server process is started.