Worksheet to configure disaster recovery for Infrastructure Management (SAP SQL Anywhere)
The following table lists the steps that you must perform to configure a Infrastructure Management disaster recovery system. Use the table to record the required disaster recovery information and confirm actions. This information will help you perform a seamless configuration of disaster recovery setup.
Worksheet to configure disaster recovery setup
Decision or requirement | Your entry |
---|---|
| |
Specify an alias name for the primary BMC TrueSight Infrastructure Management Server. |
|
| |
Edit the hosts file with an entry for the alias name set for the primary BMC TrueSight Infrastructure Management Server. |
|
Record the following parameters. You must enter the same ones during installation of recovery server:
|
|
Enable Disaster Recovery Mode. |
|
(Windows only) For the BMC TrueSight Infrastructure Management Server service and the Infrastructure Management Database Engine service, set the Startup type to Manual. |
|
| |
To flush and reset the cache, open a command prompt on a remote event cell and run the following command: |
|
Restart the remote event cell, and similarly, configure all the remote event cells. |
|
| |
Stop the primary BMC TrueSight Infrastructure Management Server. |
|
Use the same entries that you configured for the primary BMC TrueSight Infrastructure Management Server:
|
|
Enable Disaster Recovery Mode. |
|
On the recovery BMC TrueSight Infrastructure Management Server, edit the hosts file with an entry for the <aliasName>that is the same alias name as the one on the primary server. |
|
(Windows only) For the BMC TrueSight Infrastructure Management Server service and the Infrastructure Management Database Engine service, set the Startup type to Manual. |
|
Restart the computer with the recovery BMC TrueSight Infrastructure Management Server. |
|
Stop the recovery BMC TrueSight Infrastructure Management Server. |
|
If the following processes are running on your computer, end them:
|
|
Copy the entire \pw directory from the primary BMC TrueSight Infrastructure Management Server to the \pw directory of the recovery BMC TrueSight Infrastructure Management Server. |
|
Move all the log files from \pw\pronto\logs to a backup directory. |
|
Start the recovery BMC TrueSight Infrastructure Management Server and validate the configuration. |
|
Stop the recovery BMC TrueSight Infrastructure Management Server. |
|
Restart the primary BMC TrueSight Infrastructure Management Server. |
|
Back up the database files and configuration files at regular intervals |
|
Back up configuration files. |
|
Back up KB files files. |
|
Back up cell database files. |
|
Back up database files. |
|