Configuring the event buffer


If the PATROL Agent loses the connection to BMC Helix Operations Management, it will continue buffering events in its cache. After the connection is reestablished, the PATROL Agent will send the cached events to BMC Helix Operations Management.

The time period for which the events are cached is configured using a pconfig variable:

/AgentSetup/bemBufferKeepWait 

Refer the following table to set the event buffering duration:

Consideration

Value

Unit used

Minutes

Minimum value

15

Maximum value

1440

Default value

60

 