Creating a Couchbase 2.0 on RHEL 5.4 service offering


This topic describes the tasks that you must perform in BMC Cloud Lifecycle Management to create the service offering that the end user could then use to provision the application infrastructure (for example, an OS and an application package). It includes the following topics:

To create the service and the service offering

In the BMC Cloud Lifecycle Management Administrator console, you must add a service and a service offering.

For Couchbase service blueprint, you can create a service and service offering based on the available deployment model. The Couchbase service blueprint supports the following service deployment models:

Deployment model

Description

Setup Cluster deployment model

In the setup cluster deployment model, the Couchbase cluster is created on single server instance.

Add Node To Cluster deployment model

In the add node to cluster deployment model, a Couchbase node is created which is then associated to the Couchbase cluster.

To create a service

Error

Excerpt named creatingservice was not found in document xwiki:Automation-DevSecOps.Client-Management.BMC-Cloud-Lifecycle-Management.clm31._CSMinclusionsLib._inclusionsLibZipKits._createServiceOfferings.WebHome.

To create a service offering

Error

Excerpt named creatingserviceoffering was not found in document xwiki:Automation-DevSecOps.Client-Management.BMC-Cloud-Lifecycle-Management.clm31._CSMinclusionsLib._inclusionsLibZipKits._createServiceOfferings.WebHome.

To make the provisioning request

To make provisioning request for Couchbase cluster or node:

  1. Access Workspaces > Service Instances to display the Service Instances workspace, and click the New Service Request icon to display the New Service Request dialog box.

    serviceinstances_request1.png
  2. In the New Service Request dialog box, click the server provisioning service you want to request to display the Submit Request dialog box.To complete the Service Request for Couchbase cluster, specify the following Parameters:

    Clister.PNG

     

    Parameter

    Description

    Name Of Bucket

    Buckets are used to compartmentalize data within a Couchbase Server. This parameter represents the name of the bucket.

    Password Of Cluster

    Administrator password for accessing the cluster.

    Confirm

    Administrator password for accessing the cluster.  

    RAM Size Bucket

    The logical size of a bucket.

    RAM Size Of Cluster

    RAM size quota for a specific cluster.

    Replica Count Of Bucket

    This represents the bucket replication count.

    Type Of Bucket

    This represents the bucket type.

    Username Of Cluster

    Administrator username for accessing the cluster.

  3. To complete the Service Request for Couchbase node, specify the following Parameters:

    node5.4.PNG

     

    Parameter

    Description

    IP Address of Cluster

    IP address for Couchbase server.

    Password of Cluster

    Password for Couchbase server.

    Confirm

    Password for Couchbase server.

    Username of Cluster

    Username for Couchbase server.

  4. Click Next.
     
  5. Enter the data in the required fields to complete the request for an instance of the service request. You can click Next to review the details.
    serviceinstances_request_submit.png
  6. Click Submit. The request is added to the Pending Activity list in the Service Instances window.

The request status is displayed in the Pending Activity list of the Service Instances window. You can double-click on the service request to see its detailed information.

For more detailed procedures, see Requesting cloud services.

To validate the provisioned components

After provisioning the service blueprint, you can validate the Couchbase components setup in your environment.

Component name

How to verify

Results

Verify Selinux status

To verify Selinux status, run the following command:

sestatus

It displays the Selinux status which is disabled.

Couchbase installation

To verify the Couchbase installation, run the following command:

rpm -qa | grep -i couchbase

It displays the following output:

couchbase-server-2.0.1-170.x86_64

Couchbase server status

To verify the Couchbase server status, run the following command:

service couchbase-server status

It displays the following output:

couchbase-server is running

Start Couchbase server

To start the Couchbase server, run the following command:

service couchbase-server start

Starts the Couchbase service.

Couchbase server port

To verify the Couchbase listening ports, run the following command:

netstat -atpn | grep -i beam

It displays Couchbase listening ports.

Check Couchbase server list

To check the Couchbase server list, run the following command:

server-list

It displays the list of all Couchbase servers present in a cluster.

Check Couchbase server information

To check Couchbase server information, run the following command:

server-info

It displays the Couchbase server details.

Check bucket list

To check bucket list in a cluster, run the following command:

bucket-list

It displays all the buckets of a cluster.

Where to go next

Once you have created the service offering, the cloud end user can request a service offering from the My Cloud Services Console. To view a list of tasks the cloud end user can perform to manage your cloud services, see Managing cloud services in the BMC Cloud Lifecycle Management online technical documentation.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*