Unsupported content This version of the documentation is no longer supported. However, the documentation is available for your convenience. You will not be able to leave comments.

Enabling the TriggerFailsafeUtility escalation


(Issue QM001761614) After installing BMC Cloud Lifecycle Management, you must enable the RE:TriggerFailsafeUtility escalation on the enterprise BMC Remedy AR System server and the cloud BMC Remedy AR System server.

The fail safe utility monitors a reconciliation job that runs frequently at certain intervals. This utility monitors the progress of the job and restarts the job automatically if the job stops responding, so that you do not need a manual intervention.

To enable the RE:TriggerFailsafeUtility escalation

  1. On the BMC Remedy AR System server, open a command window.
  2. Navigate to the *\BMC Software\ARSystem\Arserver\api\driver* directory.
  3. Start the driver program from the command line.
     The prompt changes to Command. For more information about the driver program, see Using the driver program from the command line.
  4. Run the following commands from the prompt:
    1. Command: init 


      INITIALIZATION

         ARInitialization  results
      ReturnCode:  OK
      Status List : 0 items
    2. Command: log 


      Control record:
         Authentication string () :
        User name () : Demo
         Password () :
         Locale[.charSet] () :
         Time zone () :
         Server () : localhost
    3. Command: ses
      SET ESCALATION
    4. Escalation name: RE:TriggerFailsafeUtility 


      Change escalation name? (F):
      Change escalation time ? (F):
      Workflow type (1):
      Change schema or schemaList? (F):
    5. Change enable flag? (F): T
    6. Disable/Enable (0-1) (1): 1 


      Change query? (F):
      Change action(s)? (F):
      Change else(s)? (F):
      Change help text? (F):
      Change owner? (F):
      Add to change diary? (F):
      Change object properties? (F):
      Object Modification Log Label ():

      ARSetEscalation  results
      ReturnCode:  OK
      Status List : 0 items 
  5. Verify that the RE:TriggerFailsafeUtility escalation is enabled by using BMC Remedy Developer Studio.

Related topics

Known-issues-and-workarounds
Using the driver program

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*