This section describes how to upgrade from BMC ProactiveNet Server 9.0.xx or 9.5.xx to 9.6.xx on Microsoft Windows.
For Windows 2012, ensure that the PowerShell execution policy is running in the unrestricted mode.
Note
When you upgrade BMC ProactiveNet on a 64-bit operating system, the JServer, Rate, and Agent Controller processes use 64-bit JRE, and the Self-monitoring Service process uses 64-bit JRE on Windows and 32-bit JRE on Solaris. If you have already configured the 64-bit JRE processes in an earlier version of BMC ProactiveNet, they are retained.
This section explains the steps to upgrade BMC ProactiveNet Server on the primary node. Failover is automatically handled by Microsoft Clustering services.
Log on to a virtual node, ensuring that you are on the primary node.
Open the command prompt with the Run as administrator option. Access the <installerLocation>\Windows\BPPMServer\Disk1 directory (where installerLocation is a directory where you have downloaded installer files) and run the following command:install.cmd -J INSTALL_TYPE=PRIMARY
Perform step 4 through step 21 of Upgrading BMC ProactiveNet Server 9.0.xx or 9.5.xx to 9.6.00 on Microsoft Windows.
The following procedures explain how to upgrade the BMC ProactiveNet Server on a secondary node. Failover is handled automatically by Microsoft Clustering services.
Ensure that the BMC ProactiveNet Server is shut down on the primary node and that cluster control is moved to the secondary node computer.
Log on to a virtual node, ensuring that you are on the secondary node.
install.cmd -J INSTALL_TYPE=SECONDARY
On the Read the License Agreement and Select the Appropriate Option page, select I agree to the terms of the license agreement, and click Next. The upgrade routine automatically checks for the upgrade requirements. If it finds any errors, it displays them on a separate window. You can quit the upgrade process at this point, correct the indicated discrepancies, and then rerun the upgrade. The upgrade routine automatically detects the installation directory of the BMC ProactiveNet Server.
Note
If .NET Framework version 3.0 is not installed, you receive an error message. To install .NET Framework, use the Role Management tool. For more information about how to install the .NET Framework, go to the Microsoft web site. When .NET Framework is installed, the upgrade routine starts to copy the files to the specified directory.
Note
You must set dependencies each time you upgrade BMC ProactiveNet Server on a cluster. For example, if you are first upgrading to BMC ProactiveNet Server 9.0.xx or 9.5.xx, you set the dependencies for the cluster. Then, when you upgrade to BMC ProactiveNet Server 9.6.00, you set the dependencies again for 9.6.00.