Configuring the Assignment Engine server settings
You can use the AR System Assignment Engine: Server Settings form to enable the Assignment Engine logs and configure the logging settings.
AR System Assignment Engine: Server Settings form
To configure the AR System Assignment Engine: Server Settings form, navigate to BMC Remedy AR System Administration Console > Quick Links > Assignment Engine Administration > Sever Settings.
The following Assignment Engine settings are modified by using the AR System Configuration Generic UI form. Do not use the ar.cfg file to modify the following configuration settings:
- AE-Trace
- AE-Trace-File
- AE-Log
- AE-Log-File
- AE-Worker-Thread
Assignment Engine log file format
The format of the Assignment Engine log files is consistent with the AR System server log files. The actual content may vary according to Assignment Engine logging needs. The following sample shows an Assignment Engine log file entry:
<Overlay-Group: 0> /* Mon Aug 25 2014 14:59:13.2000 */
INFO Main Thread is waiting for Cache to be built for the first time.
For more information, see Assignment-Engine-logs.
To check whether the Assignment Engine logging is enabled, verify the value of the com.bmc.arsys.assignment setting. For more information, see Configuration-settings-A-B.