Perform the following steps to configure the BRIE logs:
- Select Administration Console > Application Administration Console > Custom Configuration > Service Level Management > Configure Application Settings > Preferences.
- In the SLM Engine area, specify the Size of Log File field.
The default value is 0, which means that the size of the log can be unlimited. - In the SLM Engine area, select Yes.
In the Location and Name of File field, enter the path and the name of the log to be created.
...\BMC Software\ARSystem\Arserver\Db\BRIE.log
- Click Save.
- Build the required service target.
Check the logs.
- If you are on AR System server 9.0, 9.0.01, or 9.1, and see the following message in the BRIE logs, contact BMC Support to get the latest SLMBRSVC (BRIE engine).
Service Targets - : Data Source rules and SVT are stuck in "Build In Progress".
Error in BRIE log -: SLM BRIE DataEvent::Process: bad return value (0) or bad number of fields (got 9, expected 8); failing
- Before you restart the AR services, perform the following steps to ensure that there are no pending or repeated pending actions for BRIE:
- In a browser, enter the following URL to open the Application Pending form:
http://<midTierServer>/arsys/forms/<ARSystemServer>/<formName>
For example, http://vw-us-rem-qa:8080/arsys/forms/vw-us-rem-qa/Application Pending. - In the Category box, enter BR-BRIE, and click Search.
- Select all the records from the results pane, and click Delete.
If the number of records in the Application Pending form are too many, you can get performance issues and can result in the SVT being in queue with Build in progress status.
Important: After the AR Services are restarted, build the service targets that had initially failed.