Information
Limited support BMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Storage Reporting 8.1.

VSCAN SMMSYSxx parameters


Use the SMMSYSxx parameters in the following table to tune VSCAN collection performance and to specify collection data set attributes.

 VSCAN parameters

Parameter

Description

PDSE_USED=YES | NO | Y | N

Specifies whether to calculate the true PDSE percent used value in views, in policy interval collections, and in processing of any AUTODS commands

PKG_DSP2=YES | NO | Y | N

Indicates whether a second dataspace will be created and used by VTOC Scan collection

VSCAN_DCLAS=dataClass

Specifies the data class used by the VTOC Scan temporary data set

VSCAN_DIR=YES | Y | NO | N

Indicates whether the VTOC scan should maintain a directory of VTOC scan collection data set control records

VSCAN_DPRI=nn

Specifies the primary allocation size of the VTOC scan collection data set directory, in cylinders

VSCAN_DSEC=nn

Specifies the secondary allocation size of the VTOC scan collection data set directory, in cylinders

VSCAN_DUNIT=xxxxxxxx

Specifies the unit of the VTOC scan collection data set directory

VSCAN_DVOL=volume

Specifies the volume of the VTOC scan collection data set directory

VSCAN_MNTSK=nn

Specifies the minimum number of tasks (TCBs) used by the VTOC Scan to perform the collection

VSCAN_MXTSK=nn

Specifies the maximum number of tasks (TCBs) used by the VTOC Scan to perform the collection

VSCAN_OCOMP=YES | NO | Y | N

Indicates whether VTOC Scan should compress collection data sets

VSCAN_OINDX=xxxxxxxxxx

Specifies the prefix name of the VTOC Scan collection data set

VSCAN_OPRI=nnnn

Specifies the primary allocation size in cylinders for the VTOC Scan collection data set

VSCAN_OSEC=nnnn

Specifies the secondary allocation size in cylinders for the VTOC Scan collection data set

VSCAN_OUNIT=xxxxxxxx

Specifies the direct access device type of the VTOC Scan collection data set

VSCAN_OVOL=xxxxxx

Specifies the volume serial number of the VTOC Scan collection data set

VSCAN_REFDD=YES | NO | Y | N

For a KSDS data component, specifies whether VTOC Scan should obtain the more recent last reference date from the data and index components.

Note: An increase in VTOC Scan elapsed and CPU time might occur, depending on the number of KSDS data sets that are being processed.

VSCAN_REFDI=YES | NO | Y | N

For a KSDS index component, specifies whether VTOC Scan should obtain the more recent last reference date from the data and index components.

Note: An increase in VTOC Scan elapsed and CPU time might occur, depending on the number of multivolume data sets that are being processed.

VSCAN_REFDM=YES | NO | Y | N

For a data set on a secondary volume, specifies whether VTOC Scan should obtain the more recent last reference date from the secondary volume and the primary volume.

Note: An increase in VTOC Scan elapsed and CPU time might occur, depending on the number of multivolume data sets that are being processed.

VSCAN_RUSEA=YES

Specifies whether data set statistical record reuse should be attempted by non-master VTOC Scans and by the AUTODS process with HIST=NO

The keyword must be set to YES, and VSCAN_RUSEV must be met to attempt data set statistical record reuse.

VSCAN_RUSEM=YES

Specifies whether data set statistical record reuse should be attempted by master VTOC Scans

VSCAN_RUSEV=nnnnn

Specifies the number of volumes that must be collected before attempting data set statistical record reuse on non-master VTOC Scans

VSCAN_SCLAS=storageClass

Specifies the storage class used by the VTOC Scan temporary data set

VSCAN_TPRI=nnnn

Specifies the primary allocation size in cylinders for the VTOC Scan temporary data set

VSCAN_TSEC=nnnn

Specifies the set secondary allocation size in cylinders for the VTOC Scan temporary data

VSCAN_TUNIT=xxxxxxxx

Specifies the device type for the VTOC Scan temporary data set

VSCAN_TVOL=xxxxxx

Specifies the volume serial number for the VTOC Scan temporary data set



 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*