Limited support BMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support. BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Ops Infrastructure 7.1.

Architecture of BMC AMI Ops threshold management


The 

BMC AMI Ops

 threshold management architecture involves:

  • Collecting BMC AMI Ops performance data from one or more BMC AMI Ops host servers on the mainframe
  • Storing that data in a Capacity Management Database (CDB) server
  • Performing statistical analysis on the collected data
  • Generating recommended threshold values and displaying them in tabular and graphical formats in a web browser
  • Pushing the recommended thresholds to the mainframe via a User Interface Middleware (UIM) server
  • Storing the pushed thresholds (and any manually created threshold definitions) in the CASPERM registry for the system where the thresholds are to be used

BMC AMI Ops

 threshold management architecture