Limited supportBMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Ops Infrastructure 7.1 .

Viewing all CAS definition members (CASDEFL view)


Use the CASDEFL view to view and manage CAS definition members (BBMTYBxx) in your CAS definition parameter (UBBPARM) library. 

To access the CASDEFL view, perform one of the following tasks:

  • In Plex Manager, type CASDEFL on the COMMAND line and press Enter.
  • From any BMC AMI Ops product that is running in windows mode, use the following CONtext command to access Plex Manager and display the CASDEFL view:  
    CON * PLEXMGR;CASDEFL

The CASDEFL view is displayed.

ddmmmyyyy  hh:mm:ss -------  BMC AMI Ops WINDOW INTERFACE (Vv.r.mm) --------------
COMMAND  ===>                                                 SCROLL ===> PAGE
CURR WIN ===> 1        ALT WIN ===>
>W1 =CASDEFL===========SYSB=====*========ddmmmyyyy==hh:mm:ss====PLEXMGR==D====2
CMD SFX Description                   Member       Cur Modify time  Modify date  Modify user
--- --- --------                      --------     --- -----------  -----------  --------
    XX  Test CAS                      BBMTYBXX     No  17:03        2018/01/01   MVSUSR1
    00  Production CAS                BBMTYB00     Yes 14:55        2018/01/31   MVSUSR1


Note

Yes, under the Cur field, identifies the currently connected CAS.

For more information about any field in the CASDEFL view, place the cursor on the field and press the Help key.

 