TM INITS
APPLICABLE TO ThruPut Manager AE |
This command displays or updates the status of ThruPut Manager dynamic initiators.
Scope: System
Duration: Until next TM INITS command or next IPL.
TM INITS | [? | HELP] |
Requests the command syntax from HELP.
Is the number of dynamic Job Analyzer initiators that will be started per 100 jobs currently in the analysis queue excluding the first 100 jobs.
AN is a short form for this keyword.
- nn - Is a number in the range 0 to 99.
If the value of ANALYZERS is 0 and the value of MINANAL is also 0, no dynamic Job Analyzer initiators will be started.
The number of dynamic Job Analyzer initiators that will be started for the first 100 jobs in the analysis queue is the value of MINANAL.
If the value of MINANAL is 0, then the value specified for ANALYZERS is the number of analyzers started for the first 100 jobs.
Displays information about the dynamic initiators. This is the default.
D is a short form for this keyword.
Is the maximum number of dynamic Job Analyzer initiators that will be started.
MAX is the shortest form of this keyword.
- nnnnn - Is a number in the range 0 to 32767.
If the value of MAXANAL is 0 then the number of dynamic Job Analyzer initiators is unlimited.
If the value of ANALYZERS is reset to 0 then the value of MAXANAL is forced to 0 - because the number of dynamic Job Analyzer initiators cannot increase.
Is the number of dynamic Job Analyzer initiators that will be started for the first 100 jobs currently in the analysis queue.
MIN is the shortest form of this keyword.
- nnnnn - Is a number in the range 0 to 32767.
If the value of ANALYSERS is 0 then the number of dynamic Job Analyzer initiators is fixed at the value of MINANAL - because the number of dynamic Job Analyzer initiators cannot increase.
If the value of MINANAL is 0 then the number of dynamic Job Analyzer initiators that will be started for the first 100 jobs in the analysis queue is the value of ANALYZERS.
A non 0 value of MAXANAL must exceed the value of MINANAL by at least the value of ANALYZERS.
Is the dynamic initiator recycle job count.
RECYCLEJ is a short form for this keyword.
- nnnn - Is a number in the range 1 to 9999.
Is the dynamic initiator recycle time, expressed in hours.
RECYCLET is a short form for this keyword.
- nn - Is a number in the range 1 to 99.
Examples:
This command requests a display of the status of dynamic initiators, and results in a display resembling the following:
ANALYZERS=nn MIN=nnn MAX=nnn
RECYCLETIME=nn
RECYCLEJOBS=nnnn
MAXIMUM=nnnn
SLM MAXIMUM=nnnn
STARTED=nnnn
HALTED=nnnn
DRAINED=nnnn
Initiator Busy < History of deployed initiators >
--Type-- Now Now 5Min 10Min 20Min 30Min 1Hour
Common nnnn nnnn nnnn nnnn nnnn nnnn nnnn
Analyzers nnnn nnnn nnnn nnnn nnnn nnnn nnnn
ON_DEMAND nnnn nnnn nnnn nnnn nnnn nnnn nnnn
The history portion of this display is a snapshot, showing the number of dynamic initiators of each type that were deployed at 5, 10, 20, 30 and 60 minutes ago.