Installing Data Studio for use with Total Test


Total Test users can create test cases to execute File-AID/RDX specifications. Perform the following steps to configure Data Studio for use with Total Test. 

Warning

Important

A File-AID/EX communication manager installed with File-AID Services is required for this feature when using Total Test to execute File-AID/RDX specifications in a CLI environment.

  1. Install and configure File-AID/EX execution server. A standalone remote execution server is required for use with Total Test to execute File-AID/RDX specifications. This is only necessary if an upgrade for the remote execution server is needed or if no existing remote execution server is defined. For more information, see Installing Standalone File-AID/EX Execution Server(s).
  2. Install and configure File-AID Services. This will install the File-AID/EX communication manager that is required by Total Test. For more information, see Installing File-AID Services.

    Warning

    Important

    If the File-AID/EX communication manager default port 4901 conflicts with another port number on the system where File-AID Services is installed, use the File-AID Services configuration utility to change the port number. If the port number is changed, you need to stop and restart the File-AID/EX communication manager windows service.

  3. Configure Workbench for Eclipse Client for use of the File-AID/EX communication manager. For more information, see the Data Explorer User Guide topic regarding managing communication managers.

    Warning

    Important

    The Workbench for Eclipse Client, File-AID Services (FAS), File-AID/EX communication manager, and remote execution server must have the same version number.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*

BMC AMI DevX Data Studio 23.02