SVC Dump Diagnostic Summary screen
The SVC Dump Diagnostic Summary screen displays information relating to the abending job. This screen consists of two pages. The following figure shows the first page of a SVC Dump Diagnostic Summary screen for a SVC dump.
SVC Dump Diagnostic Summary, page 1
Abend-AID ----------------------------------------- SVC Diagnostic Summary ----
COMMAND ===>
CXZPCPWR S0C1-01
Dump Type............ SVC Dump Active Load Module... CWPPDRVR
Completion code...... S0C1 Entry point.......... 3DC00000
Reason code.......... 00000000 Module Length........ 00088000
Translation Except... 3E1A2400
Breaking-Event-Addr.. 00000000_3DC4EDC2
PSW.................. 078D2000 BDC217F4 ILC: 02 INTC: 0001 ASID: 01B8
Address Offset Object Code Mnemonic and Operands
3DC217F2 000217F2 0000 DATA '0000'
GPR 0 GPR 1 GPR 2 GPR 3
00000000_8F6403FC 00000000_00008110 00000000_00000000 00000000_3E000400
GPR 4 GPR 5 GPR 6 GPR 7
00000000_0000FCA8 00000000_3DCA01C0 00000000_3DC1ED68 00000000_3E113A70
GPR 8 GPR 9 GPR 10 GPR 11
00000000_00007B60 00000000_3DC214E0 00000000_3DC1FD68 00000000_3DC02000
GPR 12 GPR 13 GPR 14 GPR 15
00000000_00008C3C 00000000_00008D20 00000000_BDC217EC 00000000_0000002C
AR 0 AR 1 AR 2 AR 3 AR 4 AR 5 AR 6 AR 7
008F8440 00000000 00000000 00000000 00000000 00000000 00000000 00000000
COMMAND ===>
CXZPCPWR S0C1-01
Dump Type............ SVC Dump Active Load Module... CWPPDRVR
Completion code...... S0C1 Entry point.......... 3DC00000
Reason code.......... 00000000 Module Length........ 00088000
Translation Except... 3E1A2400
Breaking-Event-Addr.. 00000000_3DC4EDC2
PSW.................. 078D2000 BDC217F4 ILC: 02 INTC: 0001 ASID: 01B8
Address Offset Object Code Mnemonic and Operands
3DC217F2 000217F2 0000 DATA '0000'
GPR 0 GPR 1 GPR 2 GPR 3
00000000_8F6403FC 00000000_00008110 00000000_00000000 00000000_3E000400
GPR 4 GPR 5 GPR 6 GPR 7
00000000_0000FCA8 00000000_3DCA01C0 00000000_3DC1ED68 00000000_3E113A70
GPR 8 GPR 9 GPR 10 GPR 11
00000000_00007B60 00000000_3DC214E0 00000000_3DC1FD68 00000000_3DC02000
GPR 12 GPR 13 GPR 14 GPR 15
00000000_00008C3C 00000000_00008D20 00000000_BDC217EC 00000000_0000002C
AR 0 AR 1 AR 2 AR 3 AR 4 AR 5 AR 6 AR 7
008F8440 00000000 00000000 00000000 00000000 00000000 00000000 00000000
The following figure shows the second page:
Abend-AID --------------- SVC Diagnostic Summary ------- Row 000022 of 000037
COMMAND ===> SCROLL ===> PAGE
AR 0 AR 1 AR 2 AR 3 AR 4 AR 5 AR 6 AR 7
00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
AR 8 AR 9 AR 10 AR 11 AR 12 AR 13 AR 14 AR 15
00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
Additional Information:
Job Name............. AACICSABDate of abend........ 22MAY2019
Step Name............ AAV11R03 Time of abend........ 13:02:41
Procedure Name....... N/A
SDWA address......... 020F6708 Dump Header Record... DMPH
TCB requesting dump.. 008A4E00 TCB Summary.......... TCBS
RTM2 Work Area....... 7F51BD60 Storage Analysis..... MVSS
z/Arch Extensions.... ARCH
COMMAND ===> SCROLL ===> PAGE
AR 0 AR 1 AR 2 AR 3 AR 4 AR 5 AR 6 AR 7
00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
AR 8 AR 9 AR 10 AR 11 AR 12 AR 13 AR 14 AR 15
00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
Additional Information:
Job Name............. AACICSABDate of abend........ 22MAY2019
Step Name............ AAV11R03 Time of abend........ 13:02:41
Procedure Name....... N/A
SDWA address......... 020F6708 Dump Header Record... DMPH
TCB requesting dump.. 008A4E00 TCB Summary.......... TCBS
RTM2 Work Area....... 7F51BD60 Storage Analysis..... MVSS
z/Arch Extensions.... ARCH
To access the SVC Dump Diagnostic Summary screen for:
- Non-CICS SVC dump: Issue the S line command on the Abend-AID Directory next to the appropriate entry. If you have already selected the dump and need to return to this screen, use the DIAG fast-path command or select the Diagnostic Summary option from the Report Menu.
- CICS SVC dump: Issue the SVCD fast-path command on the Diagnostic Summary screen or select the z/OS SVC Dump Analysis option from the Primary Option menu.
To analyze the selected SVC dump, do the following:
Note information about the region dump from the fields displayed on the SVC Dump Diagnostic Summery screen. Information reported for each dump includes the following:
Screen
Information included
First Screen
- Dump Type
- Completion code
- Reason code
- Translation Exception
- Breaking Event Address Register (BEAR)
- PSW
- Active Load Module
- Entry Point
- Module Length
- Address
- Offset
- Object Code
- Mnemonic and Operands
Second Screen
- Job Name
- Step Name
- Procedure Name
- Date of abend
- Time of abend
- Dump Header Record
- SDWA address
- TCB requesting dump
- TCB summary
- RTM2 Work Area
- MVS storage analysis
- z/Architecture extensions
- Use the cursor point-and-shoot feature to access additional diagnostic information specific to the abend:
- Press Enter at the Translation Except field, the Breaking-Event-Addr field, the Entry point field, or any of the GRP fields to view the Memory Display screen.
- Press Enter at the first word of the PSW field to view the PSW Analysis screen. This field contains the Program Status Word at the time of the interrupt.
- Press Enter at the Address field or the second word of the PSW field to view the Storage Disassembly screen.
- Press Enter at the Dump Header Record field to view the Dump Header Record screen.
- Press Enter at the SDWA address field to view the System Diagnostic Work Area screen.
- Press Enter at the TCB requesting dump field to view the Task Control Block screen.
- Press Enter at the TCB Summary field to view the TCB Summary screen.
- Press Enter at the RTM2 Work Area field to view the RTM2 Work Area screen.
- Press Enter at the Storage Analysis field to access the MVS Storage Analysis menu.
- Press Enter at the z/ARCH Extensions field to access the Optional z/Architecture Features screen.
Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*