Information
Space announcement This space now contains the documentation for all the following components:
  • CHANGE ACCUMULATION PLUS
  • IMAGE COPY PLUS
  • RECOVERY MANAGER for IMS
  • RECOVERY PLUS for IMS
We are no longer updating the individual documentation spaces for these components. For the latest documentation, see BMC AMI Backup and Recovery for IMS 5.2.

MINCYL keyword


Use the MINCYL keyword to specify the minimum size (in cylinders) for a data set group or area that will be read using the start I/O access method.

See DBACC keyword for additional information. If the data set group or area is smaller than the value specified with the MINCYL keyword, the utility uses DBACC(2) (EXCP processing) to read OSAM database data sets and DBACC(1) (native access) to read VSAM database data sets.

Related topics


Uses

Optional in global options modules. Optional on the following control statements:

  • GLBL
  • GROUP
  • IC and AIC
  • OIC and AOIC

Related keywords

Refer also to the DBACC keywords.

Syntax

MINCYL(nnnn)

Values

For the value, specify the number (0-9999) of cylinders.

Default

MINCYL(0)

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*