HCI user abend codes
User ABEND Codes: Meaning of HCI user abends
USER ABEND | MODULE | REASON CODE | DESCRIPTION | ||||
U0044 | HCIRESUM | N/A | Entry to HCIRESUM was made holding an MVS Local Lock but not for the region requesting service. | ||||
Initialization Routines | |||||||
U0100 | HCIMMAIN | 001 | Unable to load HCIMINIT the initialization module. | ||||
002 | Insufficient storage for Journal Communication Area in SP=0, LOC=ANY. | ||||||
004 | Insufficient storage for save areas in SP=250, LOC=ANY. | ||||||
005 | Insufficient storage for Global Communication Area in SP=241, LOC=ANY. | ||||||
100 | Non-zero return code from SHOWCB. High order halfword contains R15 value. | ||||||
101 | Insufficient storage for VTAM control blocks in SP=0, LOC=BELOW or LOC=ANY. High order halfword contains R15 value. | ||||||
102 | Non-zero return code from VTAM GENCB macro. High order halfword contains R15 value. | ||||||
103 | Non-zero return code from MVS ATTACH attempting to attach a processing sub task. High order halfword contains R15 value. | ||||||
104 | Non-zero return code from MVS CPOOL BUILD attempting to build the DCB pool. | ||||||
105 | Non-zero return code from MVS CPOOL BUILD attempting to build the RPL pool. | ||||||
106 | Non-zero return code from MVS CPOOL BUILD attempting to build the CCB pool. | ||||||
107 | Non-zero return code from MVS CPOOL BUILD attempting to build the LUB pool. | ||||||
108 | Non-zero return code from MVS CPOOL BUILD attempting to build the RCB pool. | ||||||
109 | Non-zero return code from MVS CPOOL BUILD attempting to build the UIB pool. | ||||||
110 | Insufficient storage for WRE queue, in SP=241, LOC=ANY. High order halfword contains R15 value from GETMAIN. | ||||||
U0100 (continued) | HCIMMAIN | 111 | Insufficient storage for ORE queue, in SP=0, LOC=ANY. High order halfword contains R15 value from GETMAIN. | ||||
113 | Insufficient storage for CCB hash table in SP=0, LOC=ANY. High order halfword contains R15 value from GETMAIN. | ||||||
114 | Insufficient storage for SIT hash table in SP=0, LOC=ANY. High order halfword contains R15 value from GETMAIN. | ||||||
115 | Non-zero return code from MVS LOAD macro attempting to load a module destined for SP=245. High order halfword contains R15 value from GETMAIN. | ||||||
116 | Non-zero return code from MVS LOAD macro attempting to load a module destined for SP=0. High order halfword contains R15 value from LOAD. | ||||||
118 | An HCI specifying the same four character SUBSYSTEM_ID is currently active on this system. | ||||||
119 | Non-zero return code from MVS ESTAE macro. High order halfword contains R15 value from ESTAE. | ||||||
120 | Non-zero return code from MVS STIMERM macro. High order halfword contains R15 value from ESTAE. | ||||||
121 | In response to the message indicating that a subsystem of the same name was still active, the operator replied “A” to ABEND the new HCI. | ||||||
122 | Insufficient storage for CSA modules in SP=245, LOC=BELOW. High order halfword contains R15 value from GETMAIN. | ||||||
123 | Insufficient storage for CSA modules in SP=245, LOC=ANY. High order halfword contains R15 value from GETMAIN. | ||||||
124 | Insufficient storage for CSA modules in SP=241, LOC=BELOW. High order halfword contains R15 value from GETMAIN. | ||||||
125 | A subsystem ID was chosen for the HCI which matches an SSCT entry that was not for an HCI. You must specify a unique subsystem. | ||||||
125 | Insufficient storage for ACE queue, in SP=0, LOC=ANY. High order halfword contains R15 value from GETMAIN. | ||||||
127 | Non-zero return code from MVS CPOOL BUILD attempting to build the TEA pool. | ||||||
128 | Non-zero return code from MVS CPOOL BUILD attempting to build the TSB pool. | ||||||
130 | Error creating HCIPlex name/token pair.a | ||||||
131 | Invalid HCIPlext Control Block (HPCB) version.a | ||||||
132 | Unable to add entry for HCI job to HCIPlex Control Block (HPCB)a | ||||||
150 | Unable to load HCIMPIXT or a post-initialization exit module. See message HCIHC0095E for details. | ||||||
151 | Post-initialization exit module failed. See message HCIHC0096E for details. | ||||||
200 | Non-zero return code from MVS CPOOL BUILD attempting to build the AMB pool. | ||||||
201 | Insufficient storage for JCB areas in SP=0, LOC=BELOW. | ||||||
202 | Insufficient storage for SIT areas in SP=0, LOC=BELOW. Too many SIT entries specified. | ||||||
203 | Insufficient storage for TPT areas in SP=0, LOC=BELOW. Too many TPT areas specified. | ||||||
204 | Non-zero return code from PD FDB$SRVM macro when trying to load the configuration table. | ||||||
205 | Non-zero return code from MVS CPOOL BUILD attempting to build the PCB pool. | ||||||
206 | In the attempt to process PCB entries, no matching TPT was found for a PCB entry. | ||||||
U0100 (continued) | HCIMMAIN | 207 | In the attempt to process PCB entries, no matching AMB was found for a PCB entry. | ||||
208 | In the attempt to process SIT entries, no matching AMB was found for a SIT entry. | ||||||
209 | In the attempt to process SIT entries, no matching PCB was found for a SIT entry. | ||||||
210 | Bad open for FDBDRPL data set. | ||||||
211 | The HCICNFIG module could not be found. | ||||||
212 | Insufficient storage for the HCICNFIG module. | ||||||
213 | The Module HCICNFIG could not be loaded. | ||||||
214 | An ALIAS TPT entry could not be found. | ||||||
2102 | Unable to load the operator communications initialization module. | ||||||
2108 | Unable to load the modules required by operator communications.see description; n/a - not applicable. | ||||||
U0100 (continued) | DYNACTLG DYNAIDCM DYNAMAIN DYNASV99 | N/A | Storage for work area not available. Increase REGION parameter on EXEC statement. | ||||
Termination Routines | |||||||
U0101 | HCIMMAIN | 2108 | Unable to load the modules required by operator communications. | ||||
U0200 | HCIOMAIN HCIRMAIN | N/A | Unsuccessful initialization | ||||
U0201 | HCIJMAIN | N/A | Non-zero return code from FREEMAIN attempting to free a journal buffer. | ||||
U0202 | HCIPSCHG | N/A | Send completed with non-zero return code. | ||||
U0203 | HCIPSCHG | N/A | Deallocate completed with non-zero return code. | ||||
U0204 | HCIPSCHG | N/A | Set deallocate type completed with non-zero return code. | ||||
U0205 | HCIPSCHG | N/A | Deallocate completed with non-zero return code. | ||||
U0210 | HCIMCLEAN | N/A | The ACE queue has been exhausted while attempting to delay the delete of an ACEE. Increase the number of CCBs in the configuration assembly. | ||||
U0300 | HCIAMAIN | 002 | Unsuccessful initialization | ||||
HCIIMAIN | N/A | Unsuccessful initialization | |||||
HCIRMAIN | 005 | Unsuccessful initialization | |||||
HCITMAIN | N/A | Unsuccessful initialization | |||||
U0301 | any module | N/A | A subroutine call did not have sufficient storage to save registers in the module working storage area. Refer this problem to BMC. | ||||
U0302 | any module | N/A | A subroutine exit could not retrieve its entry registers in the module working storage area. Refer this problem to BMC. | ||||
U0303 | HCITTERM HCIUTERM | N/A | A termination request has been made and no AMB, TSB or PCB is available. Refer this problem to BMC. | ||||
U0800 | HCIACNOC HCICACCP HCICNEND HCICOPEN HCIENFSX HCIICNOI HCIMSAF HCIMUNRU HCIOESTI HCIPCRTN HCIPOSTX HCIRCTLI HCIRRCVC HCISESTI HCITMAIN HCIUCTLI HCIURTOS HCIVATNX HCIVTPNX | N/A | All Work Request Elements have been exhausted. Increase the number of WREs in the configuration assembly. | ||||
U0801 | HCIAACSC HCIAALCC HCIACNFC HCIACNOC HCIADELC HCIAPTRC HCIARCVC HCIASNDC HCIMGDSA HCIMSTIM HCIRCLDC HCIROPDC HCIRRCVC HCIVATNX HCIVLGNX HCIVLSTX HCIVNSXX HCIVSCIX HCICTPNX | N/A | Insufficient storage for a register save area. Increase the REGION= parm on the HCI EXEC statement. | ||||
U0802 | any module | N/A | Insufficient private storage to obtain module working storage area. Increase the REGION= parm on the HCI EXEC statement. | ||||
U0905 | HCIPCRTN | N/A | A corruption of the WRE chain has been detected. Refer this problem to BMC. | ||||
U3000 | HCIOPCOM | N/A | Non-zero return code from MVS ATTACH of operator task. Insufficient number of OREs. | ||||
U3001 | HCIOPCOM | N/A | Operator subtask initialize not successful. | ||||
U3002 | HCIOPCOM | N/A | Operator subtask has abended three times in a row. The entire HCI is terminated. | ||||
U3003 | HCIPCRTN | N/A | An invalid UIB address was found in word 1 of the TCB save area. | ||||
U4094 | HCIABEND | N/A | The operator issued a STOP command for a processing subtask, requesting ABEND with no dump. | ||||
U4095 | HCIABEND | N/A | The operator issued a STOP command for a processing subtask, requesting ABEND, DUMP. | ||||
Return codes are for internal errors during creation of an HCIPlex, and to contact BMC support.