HCI user abend codes


User ABEND Codes: Meaning of HCI user abends  

USER ABEND

MODULE

REASON CODE

DESCRIPTION





U0044

HCIRESUM

N/A

Entry to HCIRESUM was made holding an MVS Local Lock but not for the region requesting service.





Initialization Routines





U0100

HCIMMAIN

001

Unable to load HCIMINIT the initialization module.





002

Insufficient storage for Journal Communication Area in SP=0, LOC=ANY.





004

Insufficient storage for save areas in SP=250, LOC=ANY.





005

Insufficient storage for Global Communication Area in SP=241, LOC=ANY.





100

Non-zero return code from SHOWCB. High order halfword contains R15 value.





101

Insufficient storage for VTAM control blocks in SP=0, LOC=BELOW or LOC=ANY. High order halfword contains R15 value.





102

Non-zero return code from VTAM GENCB macro. High order halfword contains R15 value.





103

Non-zero return code from MVS ATTACH attempting to attach a processing sub task. High order halfword contains R15 value.





104

Non-zero return code from MVS CPOOL BUILD attempting to build the DCB pool.





105

Non-zero return code from MVS CPOOL BUILD attempting to build the RPL pool.





106

Non-zero return code from MVS CPOOL BUILD attempting to build the CCB pool.





107

Non-zero return code from MVS CPOOL BUILD attempting to build the LUB pool.





108

Non-zero return code from MVS CPOOL BUILD attempting to build the RCB pool.





109

Non-zero return code from MVS CPOOL BUILD attempting to build the UIB pool.





110

Insufficient storage for WRE queue, in SP=241, LOC=ANY. High order halfword contains R15 value from GETMAIN.





U0100 (continued)

HCIMMAIN

111

Insufficient storage for ORE queue, in SP=0, LOC=ANY. High order halfword contains R15 value from GETMAIN.

113

Insufficient storage for CCB hash table in SP=0, LOC=ANY. High order halfword contains R15 value from GETMAIN.

114

Insufficient storage for SIT hash table in SP=0, LOC=ANY. High order halfword contains R15 value from GETMAIN.





115

Non-zero return code from MVS LOAD macro attempting to load a module destined for SP=245. High order halfword contains R15 value from GETMAIN.





116

Non-zero return code from MVS LOAD macro attempting to load a module destined for SP=0. High order halfword contains R15 value from LOAD.





118

An HCI specifying the same four character SUBSYSTEM_ID is currently active on this system.





119

Non-zero return code from MVS ESTAE macro. High order halfword contains R15 value from ESTAE.





120

Non-zero return code from MVS STIMERM macro. High order halfword contains R15 value from ESTAE.





121

In response to the message indicating that a subsystem of the same name was still active, the operator replied “A” to ABEND the new HCI.





122

Insufficient storage for CSA modules in SP=245, LOC=BELOW. High order halfword contains R15 value from GETMAIN.





123

Insufficient storage for CSA modules in SP=245, LOC=ANY. High order halfword contains R15 value from GETMAIN.





124

Insufficient storage for CSA modules in SP=241, LOC=BELOW. High order halfword contains R15 value from GETMAIN.





125

A subsystem ID was chosen for the HCI which matches an SSCT entry that was not for an HCI. You must specify a unique subsystem.





125

Insufficient storage for ACE queue, in SP=0, LOC=ANY. High order halfword contains R15 value from GETMAIN.





127

Non-zero return code from MVS CPOOL BUILD attempting to build the TEA pool.





128

Non-zero return code from MVS CPOOL BUILD attempting to build the TSB pool.





130

Error creating HCIPlex name/token pair.a





131

Invalid HCIPlext Control Block (HPCB) version.a





132

Unable to add entry for HCI job to HCIPlex Control Block (HPCB)a





150

Unable to load HCIMPIXT or a post-initialization exit module. See message HCIHC0095E for details.





151

Post-initialization exit module failed. See message HCIHC0096E for details.





200

Non-zero return code from MVS CPOOL BUILD attempting to build the AMB pool.





201

Insufficient storage for JCB areas in SP=0, LOC=BELOW.





202

Insufficient storage for SIT areas in SP=0, LOC=BELOW. Too many SIT entries specified.





203

Insufficient storage for TPT areas in SP=0, LOC=BELOW. Too many TPT areas specified.





204

Non-zero return code from PD FDB$SRVM macro when trying to load the configuration table.





205

Non-zero return code from MVS CPOOL BUILD attempting to build the PCB pool.





206

In the attempt to process PCB entries, no matching TPT was found for a PCB entry.





U0100 (continued)

HCIMMAIN

207

In the attempt to process PCB entries, no matching AMB was found for a PCB entry.





208

In the attempt to process SIT entries, no matching AMB was found for a SIT entry.





209

In the attempt to process SIT entries, no matching PCB was found for a SIT entry.





210

Bad open for FDBDRPL data set.





211

The HCICNFIG module could not be found.





212

Insufficient storage for the HCICNFIG module.





213

The Module HCICNFIG could not be loaded.





214

An ALIAS TPT entry could not be found.





2102

Unable to load the operator communications initialization module.





2108

Unable to load the modules required by operator communications.see description; n/a - not applicable.





U0100 (continued)

DYNACTLG DYNAIDCM DYNAMAIN DYNASV99

N/A

Storage for work area not available. Increase REGION parameter on EXEC statement.





Termination Routines





U0101

HCIMMAIN

2108

Unable to load the modules required by operator communications.





U0200

HCIOMAIN HCIRMAIN

N/A

Unsuccessful initialization





U0201

HCIJMAIN

N/A

Non-zero return code from FREEMAIN attempting to free a journal buffer.





U0202

HCIPSCHG

N/A

Send completed with non-zero return code.





U0203

HCIPSCHG

N/A

Deallocate completed with non-zero return code.





U0204

HCIPSCHG

N/A

Set deallocate type completed with non-zero return code.





U0205

HCIPSCHG

N/A

Deallocate completed with non-zero return code.





U0210

HCIMCLEAN

N/A

The ACE queue has been exhausted while attempting to delay the delete of an ACEE. Increase the number of CCBs in the configuration assembly.





U0300

HCIAMAIN

002

Unsuccessful initialization





HCIIMAIN

N/A

Unsuccessful initialization





HCIRMAIN

005

Unsuccessful initialization





HCITMAIN

N/A

Unsuccessful initialization





U0301

any module

N/A

A subroutine call did not have sufficient storage to save registers in the module working storage area. Refer this problem to BMC.





U0302

any module

N/A

A subroutine exit could not retrieve its entry registers in the module working storage area. Refer this problem to BMC.





U0303

HCITTERM HCIUTERM

N/A

A termination request has been made and no AMB, TSB or PCB is available. Refer this problem to BMC.





U0800

HCIACNOC HCICACCP HCICNEND HCICOPEN HCIENFSX HCIICNOI HCIMSAF HCIMUNRU HCIOESTI HCIPCRTN HCIPOSTX HCIRCTLI HCIRRCVC HCISESTI HCITMAIN HCIUCTLI HCIURTOS HCIVATNX HCIVTPNX

N/A

All Work Request Elements have been exhausted. Increase the number of WREs in the configuration assembly.





U0801

HCIAACSC HCIAALCC HCIACNFC HCIACNOC HCIADELC HCIAPTRC HCIARCVC HCIASNDC HCIMGDSA HCIMSTIM HCIRCLDC HCIROPDC HCIRRCVC HCIVATNX HCIVLGNX HCIVLSTX HCIVNSXX HCIVSCIX HCICTPNX

N/A

Insufficient storage for a register save area. Increase the REGION= parm on the HCI EXEC statement.





U0802

any module

N/A

Insufficient private storage to obtain module working storage area. Increase the REGION= parm on the HCI EXEC statement.





U0905

HCIPCRTN

N/A

A corruption of the WRE chain has been detected. Refer this problem to BMC.





U3000

HCIOPCOM

N/A

Non-zero return code from MVS ATTACH of operator task. Insufficient number of OREs.





U3001

HCIOPCOM

N/A

Operator subtask initialize not successful.





U3002

HCIOPCOM

N/A

Operator subtask has abended three times in a row. The entire HCI is terminated.





U3003

HCIPCRTN

N/A

An invalid UIB address was found in word 1 of the TCB save area.





U4094

HCIABEND

N/A

The operator issued a STOP command for a processing subtask, requesting ABEND with no dump.





U4095

HCIABEND

N/A

The operator issued a STOP command for a processing subtask, requesting ABEND, DUMP.





Return codes are for internal errors during creation of an HCIPlex, and to contact BMC support.



 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*