Upgrade issues
There are some changes between the earlier versions and the current version that can cause issues or changes with thresholds, the user interface, and reports.
For other upgrade issues, see Known-and-corrected-issues.
The following table provides upgrade issues with thresholds, the user interface, reports, and also provides workarounds for these issues:
1 | Restoring the earlier version of BMC TrueSight Infrastructure Management Server if the upgrade fails When you upgrade the BMC TrueSight Infrastructure Management Server to 10.0, the installer automatically backs up the installation and configuration files of the earlier Infrastructure Management installation in the following folder:
However, the SAP SQL Anywhere database files and the cell configuration files are not copied into the folder. BMC recommends that you back up the database files and cell configuration files before upgrading the BMC TrueSight Infrastructure Management Server. For information about backing up the SAP SQL Anywhere database and the cell configuration files, see Prerequisites-for-upgrade. |
2 | A java.lang.NumberFormatException appears after upgrade |
3 | The cell process does not run after upgrading with a non-root user |
4 | The instance hierarchy is not displayed |
5 | Navigation tree is missing |
6 | Reusing customized local actions after upgrading
|
7 | Child server status is not accurate Explanation: |
8 | Validation error message as 'More swap space required' Explanation:
|
9 | Resuming the upgrade if the preinstallation check fails Before the upgrade process, Infrastructure Management runs a preinstallation check to check for the required settings and processes. If the check fails, an error message is displayed and the Next button is disabled. You cannot proceed to the upgrade. Workaround: Restart the Infrastructure Management processes manually and resume the upgrade process. |
10 | Unable to log into the Infrastructure Management Server using a custom user When you upgrade to the Infrastructure Management Server 10.0 and try to log into it, the internal server error or blank page is displayed. This issue occurs if the environment you are upgrading from (ProactiveNet 9.5, 9.6, or Infrastructure Management 9.6) contains any user group that has access to all Configuration Items (CIs) but does not have a Super Admin role. When you upgrade to the Infrastructure Management Server 10.0 and migrate such user group to the Presentation Server, the authorization profile for this user group is created with the information from all CIs. Therefore, when any user from this user group tries to log in, all CIs are updated with the access information and leads to timeout. Workaround: To resolve this issue, edit the authorization profile for such user group and provide 'unrestricted access' to CIs. For information about editing the authorization profile, see Editing-and-deleting-authorization-profiles. |
12 | Integration Service is stopped after Infrastructure Management installation When the Infrastructure Management Server and Integration Service is installed on a same Linux or Solaris computer, after you upgrade the Infrastructure Management Server, the Integration Service is stopped. You must start the Integration Service manually. |