Sizing the VMware vCloud Director integration
The following table helps you determine the number of Central Servers, Child Servers, Data Collection Hosts, and BMC Server Automation Servers required to integrate Infrastructure Management with VMware vCloud Director. The table shows the maximum number of devices, monitor instances, and attributes required for a proof of concept (POC) in a small environment.
Characteristic | Small environment |
---|---|
Number of monitored devices | 10,000 |
Number of monitor instances | 50,000 |
Number of attributes | 100,000 |
Duration raw data retention | 8 days |
Duration rate retention | 3 months |
Adapter type | BMC PATROL |
Polling frequency, in minutes (statistics, auto-sync) | 5, 5 |
Required number of Central Servers | 1 |
Required number of Child Servers | 1 |
Required number of Infrastructure Management Data Collection Hosts | 1 |
Required number of BMC Server Automation Servers | 1 |
Total number of computers required | 3 |
Total number of processors | 8 |
Total memory required (in GB) | 31 |
Related topics
Integrating with VMware vCloud Director
Using the operator console to monitor VMware vCloud Director objects