Resetting a baseline
Baseline can be reset to re-compute the baseline. On Reset, the baseline data is re-initialized based on previous data generated from the same instances.
All historic baseline information is deleted and the new baseline is initially just an estimate (based on the performance of the old data in the specified period).
Baseline values are refined over time as the pattern is relearned.
To reset a baseline
- Click Reset Baseline on the baseline Administration screen.
- Select the monitor instances.
- Group - Select Group to include all the instances in the group.
- SLO - Select SLO to include all instances from the SLO.
- Device - Select Device to include all the instances associated with the device.
- Monitor Type - Select Monitor Type to include all instances of the monitor type.
- Monitor Instance - Select Monitor Instance to include the single monitor instance.
- Specify the period for calculating the new baseline by using one of the following options:
- From Time and To Time - Specify the start and end time of the period for considering data for baseline calculations.
- Number of days for considering data
- Select the baseline types to be reset. Specify at least one of available baseline types (hourly, daily, or weekly).
Click Reset.