Use the Reload menu command to access the commands for reloading a cell's configuration.The Reload > Allmenu option is the equivalent of the mcontrol command's reload all option. This means the default data from the cell's KB\data directory is reloaded, reverting it to its default configuration. This removes any custom data that you have created. However, the other options, such as Reload > KnowledgeBase, Reload> Directory (mcell.dir), and so on, do not reload data.
To reload all of the cell configuration
Right-click a cell.
Select Reload > All. All configuration files and the KB are reloaded.
To reload only the cell's knowledge base
Right-click a cell.
Select Reload > Knowledge Base. The KB is reloaded.
To reload the directory
Right-click a cell.
Select Reload > Directory . The mcell.dir file is reloaded.
To reload cell configuration
Right-click a cell.
Select Reload > Cell Configuration . The configuration files mcell.conf, mcell.propagate, and mcell.modify are reloaded.
To reload trace configuration
Right-click a cell.