Configuring BMC Atrium CMDB integration
During the installation process, you have the option to configure the TrueSight Infrastructure Management Server integration with Atrium CMDB. If you did not configure the Atrium CMDB integration during installation, you can configure it post installation of Infrastructure Management.
Use the following script:
where,
- cmdbServerHostName is the host name where Atrium CMDB is running. For integration with an AR Server Group, cmdbServerHostName is the AR Server load balancer host name or the AR Server integration server host name
- cmdbServerPortNumber is the Remedy Action Request System TCP port number, used to log into the system server
- cmdbUserName is the user name to access the BMC Remedy Action Request System server
Use the following optional arguments if you need Infrastructure Management to cross-launch into other Atrium applications:
- (Optional) uddiServerHostName is the host name of the UDDI web service where Atrium CMDB is running
- (Optional) uddiServerPortNumber is the port number used by the UDDI web service on the specified host
- (Optional) uddiUserUame is the user name for the UDDI web service
- (Optional) uddiPassword is the password for the UDDI web service user
- (Optional) cmdbPassword is the password for the Remedy Action Request System server user
Use the following optional arguments if you need to enable the cross-launch into Infrastructure Management:
- webServerProtocol is the ProactiveNet web server protocol, either http (default) or https.
- proactiveNetWebServerPortNumber is the ProactiveNet web server port number. The default value is 80.
- -enterprise (T|F) indicates whether or not your enterprise environment has multiple Infrastructure Management Servers that will be communicating with the same CMDB.
For example:
If you integrate with Atrium CMDB in an AR Server Group, you must manually configure the pserver.conf file. Edit the ARSGroupMembers in the pserver.conf file and set to all AR Servers of the group that have reconciliation function enabled. See also Configuring-the-Publishing-Server-to-integrate-with-an-AR-Server-group.
If you run integrate_atrium_cmdb without providing UDDI settings and later require cross launch, then at that time you can configure the UDDI settings via the pw-cmdb settings command.
At the time of installation, if you have selected not to integrate BMC Atrium CMDB, then you need to configure SDIG. For more information, see Configuring the integration with BMC Service Resolution
To integrate Infrastructure Management with Atrium Service Context, see Enabling-cross-launch-to-Atrium-Service-Context.
Related topics