Configuring a server threshold
When you are creating or editing a monitoring policy, you can create thresholds for the monitor instances on the BMC ProactiveNet Server. For information about the types of thresholds, see How baselines, thresholds and Key Performance Indicators work together to generate events in the BMC ProactiveNet Operations Console.
This topic covers the following tasks:
Before you begin
Ensure that monitor configuration is complete before the thresholds are applied. Thresholds cannot be applied to monitors that are not configured through Central Monitoring Administration.
If you have not done so already, perform the steps provided under the following sections:
To add and configure monitor thresholds on the server
- On the Server Threshold Configuration page, click Add
.
- In the Add Instance Thresholds dialog box, select a solution, its version, and a monitor type.
In the Instance Name box, type the name of the instance or a regular expression that can match multiple instances.
In the Attribute list, select a monitor attribute.
- In the Type of Threshold list, select the threshold type that you want to configure for the selected attribute. The supported types are as follows:
- Absolute
- Signature
- Abnormality
- Configure the threshold parameters. The parameters vary based on the threshold type that you have selected.
- Click Add to add the configuration details for the threshold.
- (Optional) To configure more thresholds, repeat step 2 through step 7.
- (Optional) To reset the settings to the default values, click Reset.
- When you finish configuration, click Close.
- Click Next or Finish.
After you save or update a policy, the new threshold configurations are pushed to the selected BMC PATROL Agents.
To edit a threshold configuration
- On the Server Threshold Configuration page, select a threshold definition, and click Edit
.
- Update the configuration values, and click Update.
- After updating the threshold configuration, click Close.
After you update a policy, the updated threshold configurations are pushed to the selected BMC PATROL Agents.
To delete a threshold configuration
- On the Server Threshold Configuration page, in the Defined attribute thresholds table, perform one of the following tasks.
- To delete all the threshold configuration based on a solution name and all its version, in the Solution column, select a value.
- To delete all the threshold configuration based on a version of the monitoring solution and its monitor types, in the Version column, select a value.
- To delete all the threshold configuration based on a monitor type and its attributes, in the Monitor Type column, select a value.
- To delete all the threshold configuration based on the scope, in the Scope column, select a value.
- Click Delete
.
- In the Delete Confirmation dialog box, click Yes.
After you delete a threshold configuration and save the policy, the deleted threshold configurations are removed from the selected BMC PATROL Agents.
Where to go from here
Configuring a BMC PATROL Agent