Inter-site Replication Synchronization Status (AdIntersiteReplicationStatus)


Reports whether replication between the site/domain, site/forest, or both for a domain controller is occurring properly. Creates a PATROL Event Manager event, which contains annotated data, if the KM finds slow or failed replication data.

Notes

  • The Inter-site Replication Synchronization Status attribute in BMC ProactiveNet Performance Management is referred as the AdIntersiteReplicationStatus parameter in BMC PATROL.
  • This parameter is inactive by default. Each discovery cycle, the KM checks to see if the current domain controller (DC) is a bridgehead server. If the current server becomes a bridgehead server, then the parameter becomes active. Because the active/inactive status is determined programmatically, changing the active/inactive setting for the parameter has no effect on the active/inactive status at runtime.

Default properties

Property

Default value

BMC PATROL properties

Application classes

AD_AD_SERVER

Command type

not applicable

Platform

All computers

Icon style

graph

Unit

0=Replication Succeeded

1=Replication Interval Exceeded

2=Replication Failed

Border range

undefined

Alarm1 range

1-1 WARN

Alarm2 range

2-2 ALARM

Scheduling(poll time)

N/A

Active at installation

active/inactive status depends on environment

Parameter type

consumer

Value set by

AdReplicationCollector

BMC ProactiveNet Performance Management properties

Monitor type

Active Directory Server

Key Performance Indicator

Yes

Monitor for abnormalities

No

Graph by default

No

Availability

No

Response time

No

Normal distribution

Yes

Statistical

Yes

 