Configuring a BMC PATROL Agent
You can configure the properties of the BMC PATROL Agent and specify the action that the BMC PATROL Agent must perform when the policy is applied.
You can also configure poll interval settings for monitor types and its attributes. For more information about the various monitor types available for BMC PATROL for IT Data Analytics, see Monitor types.
This topic covers the following tasks:
Before you begin
If you have not done so already, perform the steps provided under the following sections:
To define an agent configuration
On the Agent Configuration page, under Agent Properties, provide the following details:
Field
Description
User Name
User name that you want to use to run the BMC PATROL Agent. The user name must have access permissions to the BMC PATROL Agent directory.
Password
Password for the specified user name
Confirm Password
Password for the specified user name
Restart Agent
Selecting Restart Agent restarts the BMC PATROL Agent after the policy is applied.
Note: Ensure that you select Restart Agent if you want the user name change to take effect.
Note: While editing a policy, if you select Restart Agent and provide the same default account information as what was provided while creating the policy, the PATROL Agent is not restarted. To restart the PATROL Agent, use the Query Agent screen in Central Monitoring Administration. For more information, see Executing tasks on BMC PATROL Agents.Tag
Tags that you want to assign to the BMC PATROL Agent. The format of each tag is tagName:tagDescription. If the tag description contains spaces, enclose the description within double quotes. You can also provide multiple tags, separated by commas.
For example, tag1:"Brief Description",tag2:"Description"BMC ProactiveNet Integration Service
An Integration Service or an Integration Service Cluster that you want to set as BMC PATROL Agent phone home. The supported values are as follows:
- Single Integration Service
- Integration Service Cluster
If you have selected Integration Service Cluster, you have the option to create a new cluster. Click New to create a new cluster. For more information about creating a cluster, see Managing a BMC ProactiveNet Integration Service cluster through Central Monitoring Administration.
Under Event Configuration Properties, provide the following details:
Field
Description
Events forwarding destination
Specifies where the events generated by the BMC PATROL Agents must be sent. The supported destinations are as follows:
- Integration Service Settings—Allows to use the settings on the Integration Service to which the BMC PATROL Agent is connected
- Cell(s)—Allows to send the events to one or more cells. In the Events Cells List box, specify the cells to which you want to send the events, separated by commas. The format of each cell is cellName/cellPort, where cellName is the name of the cell and the cellPort is the port number through which the agent communicates with the cell.
For example, cell1/1111,cell2/1203
Also, in the Event Cell Shared Key box, specify the shared key which is used for encryption. The default shared key is mc. - Do not send events—Stops sending the events
Events Format Container
String to append to the name of the events generated by the agents. The default string is BPPM.
- If you want to configure time intervals for data collection, under Poll Interval Settings, click Add
, and perform the following tasks:
- In the Add Poll Interval dialog box, select a solution, its version, and a monitor type.
- In the Parameter list, specify the parameter for which you want to create the poll interval.
- In the Parameter Poll Interval list, update the poll interval value.
- Click Add.
- To add more poll intervals, repeat step a through step d.
- Click Close or Finish.
To edit a poll interval
- On the Agent Configuration page, under Poll Interval, in the Parameter column, select a parameter for which you want to edit the poll interval.
- Click Edit
.
- In the Edit Poll Interval dialog box, update the poll interval, and click Update.
- Click Close.
To delete a poll interval
- On the Agent Configuration page, under Poll Interval, in the Configured Poll Interval table, perform one of the following tasks.
- To delete all the poll intervals based on a solution name and all its version, in the Solution column, select a value.
- To delete all the poll intervals based on a version of the monitoring solution and its monitor types, in the Version column, select a value.
- To delete all the poll intervals based on a monitor type and its attributes, in the Monitor Type column, select a value.
- To delete the poll intervals based on a parameter, in the Parameter column, select a value.
- Click Delete ➖️.
- In the Delete Confirmation dialog box, click Yes.
To define an agent configuration
On the Agent Configuration page, under Agent Properties, provide the following details:
Field
Description
User Name
User name that you want to use to run the BMC PATROL Agent. The user name must have access permissions to the BMC PATROL Agent directory.
Password
Password for the specified user name
Confirm Password
Password for the specified user name
Restart Agent
Selecting Restart Agent restarts the BMC PATROL Agent after the policy is applied.
Note: Ensure that you select Restart Agent if you want the user name change to take effect.
Note: While editing a policy, if you select Restart Agent and provide the same default account information as what was provided while creating the policy, the PATROL Agent is not restarted. To restart the PATROL Agent, use the Query Agent screen in Central Monitoring Administration. For more information, see Executing tasks on BMC PATROL Agents.Tag
Tags that you want to assign to the BMC PATROL Agent. The format of each tag is tagName:tagDescription. If the tag description contains spaces, enclose the description within double quotes. You can also provide multiple tags, separated by commas.
For example, tag1:"Brief Description",tag2:"Description"BMC ProactiveNet Integration Service
An Integration Service or an Integration Service Cluster that you want to set as BMC PATROL Agent phone home. The supported values are as follows:
- Single Integration Service
- Integration Service Cluster
If you have selected Integration Service Cluster, you have the option to create a new cluster. Click New to create a new cluster. For more information about creating a cluster, see Managing a BMC ProactiveNet Integration Service cluster through Central Monitoring Administration.
Under Event Configuration Properties, provide the following details:
Field
Description
Events forwarding destination
Specifies where the events generated by the BMC PATROL Agents must be sent. The supported destinations are as follows:
- Integration Service Settings—Allows to use the settings on the Integration Service to which the BMC PATROL Agent is connected
- Cell(s)—Allows to send the events to one or more cells. In the Events Cells Listbox, specify the cells to which you want to send the events, separated by commas. The format of each cell is cellName/cellPort, where cellName is the name of the cell and the cellPort is the port number through which the agent communicates with the cell.
For example, cell1/1111,cell2/1203
Also, in the Event Cell Shared Key box, specify the shared key which is used for encryption. The default shared key is mc. - Do not send events—Stops sending the events
Events Format Container
String to append to the name of the events generated by the agents. The default string is BPPM.
- If you want to configure time intervals for data collection, under Poll Interval Settings, click Add
, and perform the following tasks:
- In the Add Poll Interval dialog box, select IT Data Analytics as Monitoring Solution and 2.1.00 as the version, and ITDA Collection as the monitor type.
- In the Parameter list, specify the parameter for which you want to create the poll interval.
- In the Parameter Poll Interval list, update the poll interval value.
- Click Add.
- To add more poll intervals, repeat step a through step d.
- Click Close or Finish.