CONFIGURE THRESHOLDS dialog box


Use the CONFIGURE THRESHOLDS dialog box to specify the threshold settings for a PATROL parameter.

Procedures related to this dialog box

Setting-parameter-thresholds

Items on this dialog box

Item

Description

Active

When selected, indicates that the parameter is active and the settings in the dialog box represent the current parameter settings

Border Range

Enable the border range if it is possible for the parameter to return a value outside of the other alarm range limits. You can use this setting for information or as a third-level alert condition representing either a warning or alarm state.

Alarm Range 1

To activate, select Enable.
Use Alarm 1 as a first-level alert condition representing either a warn or an alarm state.
The Alarm 1 values must meet the following criteria:

  • Must be less than Alarm 2 values
  • Cannot overlap the Alarm 2 range
  • Cannot fall outside of the range limits or border range.

Alarm Range 2

To activate, select Enable.
Use Alarm 2 as a first-level alert condition representing either a warn or an alarm state.
The Alarm 2 values must meet the following criteria:

  • Must be less than Alarm 1 values
  • Cannot overlap the Alarm 1 range
  • Cannot fall outside of the range limits or border range.

Choose Duration of Change

If you select Apply to current session, the settings are valid until the PATROL agent is restarted.
If you select Make persistent, the settings are valid until you change them or you elect to discontinue using the PATROL KM for Event Management parameter settings and then restart the PATROL agent.

 