ConfigUpdates (DB2UDB_COLLECTORS)


The ConfigUpdates parameter checks for changes to the PATROL Configuration Variables.  When a change is detected, this parameter creates an annotation that contains the name of the configuration variable changed and how it changed.

Before a variable change can take effect, the following events must occur:

  1. Discovery or the appropriate parameters complete the next cycle.
  2. ConfigUpdate parameter runs and discovers the new configuration variable.
  3. Discovery or the appropriate parameter completes another cycle after ConfigUpdate discovers the new variable.
  4. If applicable, the appropriate collector parameter updates the effected consumer parameters.

For information about parameter poll times and dependencies see Collector and Consumer Parameter Dependencies and the help topics for any parameters effected by the variable.

Default parameter attributes

Attribute

Default value

Application class

DB2UDB_COLLECTORS

Command type

PSL

Platform

All

Active at installation

yes

Parameter type

Standard

Scheduling (poll time)

3330 seconds (55 Minutes)

Icon style

Graph

Alarm 1 range

not applicable

Alarm 2 range

not applicable

Border range

not applicable

Unit

None

Value set by

CollInstance

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*