Objects for parametersTable


The table parametersTable contains these objects:

parametersTable OBJECT-TYPE

SYNTAXSEQUENCE OF ParametersEntry
 ACCESSnot accessible
 STATUSdeprecated
 DESCRIPTION "This table is used to get/set PATROL application instance monitored parameters. PATROL Agent parameters are leaves of the information tree."
 : := {patrolObjects 8}

parametersEntry OBJECT-TYPE
 SYNTAXParametersEntry
 ACCESSnot accessible
 STATUSmandatory
 DESCRIPTION "The value and description"
 INDEX {applicationOid, applInstOid, parameterObjId}
 : := {parametersTable 1}
 parametersEntry : := SEQUENCE {
 parameterName
 parameterState
 parameterCurrentTime
 parameterCurrentValue
 parameterPollingInt
 parameterRetries
 parameterOutputMode
 parameterAutoScale
 parameterYaxisMin
 parameterYaxisMax
 parameterRowStatus
 parameterObjId
 parameterActiveStat
 parameterRunningStat

parameterName OBJECT-TYPE

SYNTAXDisplayString
 ACCESSread-only
 STATUSmandatory
 DESCRIPTION "Parameter name"
 : := {parametersEntry 1}

parameterState OBJECT-TYPE

SYNTAXStates
 ACCESSread-only
 STATUSmandatory
 DESCRIPTION "Parameter state"
 : := {parametersEntry 2}

parameterCurrentTime OBJECT-TYPE

SYNTAXTimeTicks
 ACCESSread-only
 STATUSmandatory
 DESCRIPTION "Time stamp when the current value was produced"
 : := {parametersEntry 3}

parameterCurrentValue OBJECT-TYPE

SYNTAXDisplayString
 ACCESSread-only
 STATUSmandatory
 DESCRIPTION "Parameter's current value"
 : := {parametersEntry 4}

parameterPollingInt OBJECT-TYPE

SYNTAXINTEGER
 ACCESSread-only
 STATUSmandatory
 DESCRIPTION "Parameter polling interval"
 : := {parametersEntry 5}

parameterRetries OBJECT-TYPE

SYNTAXINTEGER
 ACCESSread-only
 STATUSmandatory
 DESCRIPTION "Parameter timeout retries"
 : := {parametersEntry 6}

parameterOutputMode OBJECT-TYPE

SYNTAXOutputMode
 ACCESSread-only
 STATUSmandatory
 DESCRIPTION "Parameter output mode"
 : := {parametersEntry 7}

parameterAutoScale OBJECT-TYPE

SYNTAXPBoolean
 ACCESSread-only
 STATUSmandatory
 DESCRIPTION "True(1) means to use automatic scale. False(0) means to use the following YaxisMin and YaxisMax fields to draw y-axis scale."
 : := {parametersEntry 8}

parameterYaxisMin OBJECT-TYPE

SYNTAXINTEGER
 ACCESSread-only
 STATUSmandatory
 DESCRIPTION "Minimum value for drawing y-axis scale if parameterAutoScale is false(0)"
 : := {parametersEntry 9}

parameterYaxisMax OBJECT-TYPE

SYNTAXINTEGER
 ACCESSread-only
 STATUSmandatory
 DESCRIPTION "Maximum value for drawing y-axis scale if parameterAutoScale is false(0)"
 : := {parametersEntry 10}

parameterRowStatus OBJECT-TYPE

SYNTAXPRowStatus
 ACCESSread-write
 STATUSmandatory
 DESCRIPTION "Row status for creating a new row as defined in SNMP V2"
 : := {parametersEntry 11}

parameterObjId OBJECT-TYPE

SYNTAXINTEGER
 ACCESSnot accessible
 STATUSmandatory
 DESCRIPTION "Parameter object id"
 : := {parametersEntry 12}

parameterActiveStat OBJECT-TYPE

SYNTAXPBoolean
 ACCESSread-write
 STATUSmandatory
 DESCRIPTION "Boolean value of the parameter explaining whether the parameter was created as active"
 : := {parametersEntry 14}

parameterRunningStat OBJECT-TYPE

SYNTAXPBoolean
 ACCESSread-write
 STATUSmandatory
 DESCRIPTION "Boolean value indicating the parameter is either running or suspended for the current instance"
 : := {parametersEntry 15}

 