Controlling events displayed in PEM


You can use the allowsendparamonly variable to prevent events from being generated and displayed in the PATROL Event Manager for applications and instances when parameters change state to OK. The allowsendparamonly is defined in the [parm90:AGENT] stanza of the patrol.conf file.

The allowsendparamonly variable has the following values:

  • True: events are not generated or displayed for applications and instances when a parameter changes to an OK state.
  • False: events are generated and displayed for applications and instances when a parameter changes to an OK state. 

    Note

    You must manually create this variable in your patrol.conf file.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*