Installing the BMC Application Diagnostics Server in silent mode
The BMC Application Diagnostics Server Installer can be run in silent mode, which requires no user interaction during installation.
The following files are used to configure the silent installation of BMC Application Diagnostics Server:
- On Windows: adop-silent-option.txt
- On Linux: adop-silent-option
These files are located in the \ADOPServer\Disk1 folder in the installation file structure.
To configure the silent installation
- In a command line, open the relevant adop-silent-option file in edit mode.
Specify a valid directory into which the BMC Application Diagnostics Server should be installed, using the following format:
-P installLocation=<directory>where
<directory> is the installation location.- Add the Server components you want to install.
To install only the BMC Application Diagnostics Portal, add the following line:
-A bmc_application_diagnostics_portalTo install only the BMC Application Diagnostics Collector, add the following line:
-A bmc_application_diagnostics_collectorIf you do not want to install either of the components, add # before the component.
- Enter the Portal configuration.
- When installing the BMC Application Diagnostics Collector only, you must enter the Portal host/IP to use in the portal_ip parameter.
- When installing the BMC Application Diagnostics Portal, the portal_ip must remain localhost.
If required, modify the default port numbers. Ensure that the ports are available.
-J portal_ip=localhost
-J portal_http_port=8100
-J portal_https_port=8143
-J portal_apm_console_host=<hostname_or_IP_address>
-J portal_apm_console_https_port=443Parameter descriptions
The [confluence_table-plus] macro is a standalone macro and it cannot be used inline. Click on this message for details.
Enter the connection security level to be used by all components.
-J connection_security=<SecurityLevel>where
<SecurityLevel> is one of the following:- not_secured – Select this option to set the communication protocol to HTTP.
- encrypted – Select this option to set the communication protocol to HTTPS.
- encrypted_authenticated – Select this option to set the communication protocol to authenticated HTTPS.
- Modify the BMC Application Diagnostics Collector configuration.
If required, modify the BMC Application Diagnostics Collector port numbers for the communication protocol selected when you selected the security level. Ensure that the ports are available.
-J collector_http_port=8200
-J collector_https_port=8243Parameter descriptions
The [confluence_table-plus] macro is a standalone macro and it cannot be used inline. Click on this message for details.When installing the BMC Application Diagnostics Collector, you can modify the database retention period (days), and database size (GB).
-J db_retention_time=35
-J db_max_size=100Parameter descriptions
The [confluence_table-plus] macro is a standalone macro and it cannot be used inline. Click on this message for details.
Configure the listening address.
Enter the hostname or IP address of the computer on which you are installing the Server.
-J linkback_address=Configure the database.
Enter the port number for the MySQL 5.5 database that will be created during the installation process. The default port number is 3301.
-J db_port=3301
To run the Installer in silent mode
- In a command line, navigate to the \ADOPServer\Disk1 folder in the installation file structure.
- Enter the following command to install the BMC Application Diagnostics Server in silent mode:
On Windows:
setup.cmd -i silent -DOPTIONS_FILE=adop-silent-option.txtOn Linux:
./setup.sh -i silent -DOPTIONS_FILE=adop-silent-option
Where to go from here