Managing the BMC Application Diagnostics Server services


The BMC Application Diagnostics Server comprises the BMC Application Diagnostics Portal, and the BMC Application Diagnostics Collector. After making any manual changes to the configuration files of these components, you must restart the component.

This topic provides the Microsoft and Linux commands for stopping and starting the BMC Application Diagnostics Server services.

Linux commands

  • To stop the BMC Application Diagnostics Portal service, run the following command: 

    service adop_portal stop
  • To start the BMC Application Diagnostics Portal service, run the following command: 

    service adop_portal start
  • To stop the BMC Application Diagnostics Collector service, run the following command: 

    service adop_collector stop
  • To start the BMC Application Diagnostics Collector service, run the following command: 

    service adop_collector start
  • To verify that the services have started, run the following command: 

    ps -ea | grep adop

     All running processes are displayed. Verify that the installed components (adop_portal or adop_collector, or both) are displayed.

Windows commands

You can use the Windows services manager (services.msc) to stop and start the BMC Application Diagnostics Server components.

The following services are listed for their respective installed components:

  • BMC Application Diagnostics Portal
  • BMC Application Diagnostics Collector

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*

BMC Application Diagnostics 1.3