Technology Knowledge Update 2015-Apr-1
BMC Atrium Discovery Technology Knowledge Update 2015-Apr-1 is a deliverable for BMC Atrium Discovery 9.0, 10.0 and 10.1 series.
Release Compatibility
TKU 2014-Apr-1 is released in three streams:
- Release compatible with BMC Atrium Discovery 9.0 series
- Release compatible with BMC Atrium Discovery 10.0 series
- Release compatible with BMC Atrium Discovery 10.1 series
Download
Customers can access this TKU release from the BMC Electronic Product Distribution Website. If you are a customer or partner and do not already have a login please contact your BMC account manager.
Check out this demo if you are unsure how to download from BMC EPD site.
Contents
The release comprises components packaged as two entities:
- BMC Atrium Discovery Technology Knowledge Update
- Core - Patterns that model various software products
- Extended Database discovery - Patterns that extend some of the core database patterns to obtain additional detailed information about certain databases
- Middleware discovery - Patterns that obtain detailed information about certain J2EE Application Servers and Web servers
- Network Device Integration Module with associated Network Device definition files, Printer definition files and SNMP Managed Device definition files
- System - Patterns that detect configuration issues and populate Discovery Conditions (Atrium Discovery 9.0.xx , Atrium Discovery 10.0.xx, Atrium Discovery 10.1.xx) as well as patterns used by the CMDB sync system
- BMC Atrium Discovery Extended Data Pack, which is a separately licensable product.
- Product Lifecycle - Patterns that populate Atrium Discovery with information about End-of-Life, End-of-Support, and End-of-Extended-Support for versions of certain host Operating Systems as well as versions of certain software products
- Hardware Reference Data - Patterns and data import CSV file that populate Atrium Discovery with power and heat consumption figures for various hosts.
Installation and Upgrade
- Atrium Discovery 9.0 series - Installation and upgrade instructions are provided here
- Atrium Discovery 10.0 series - Installation and upgrade instructions are provided here
- Atrium Discovery 10.1 series - Installation and upgrade instructions are provided here
A matrix covering ALL commands executed and ALL files retrieved by the patterns is available to our customers from the BMC Electronic Product Distribution Website. The filename is TKU_Command_File_Matrix-2015-04-1.xls
New Pattern Modules
Vendor | Product | Category | Platforms | Instances | Versioning | Product Page |
---|---|---|---|---|---|---|
Open Source | Tripwire | Security and Vulnerability Management Software | Unix, Windows | Y | Y | |
Tripwire | Tripwire Enterprise | Security and Vulnerability Management Software | Unix, Windows | Y | Y | |
Eclipse | Jetty | Development Languages, Environments, and Tools | Unix, Windows | Y | Y | |
Open Source | Logstash | Performance Management Software | Unix | Y | Y | |
Sumologic | Sumologic | Performance Management Software | Unix, Windows | Y | Y | |
Perforce | Helix | Development Languages, Environments, and Tools | Unix, Windows | Y | Y |
Enhanced Pattern Modules
RFE ref. | Product Page | Enhancement | SI Key Change |
---|---|---|---|
TKU-2276 | The pattern has improved key generation method. | Y | |
TKU-3775 | Improved package versioning. | N | |
TKU-2275 | Improved versioning. | N | |
QM001877897 | The pattern was enhanced to support some versions of Microsoft System Center Data Protection Manager Software Instance. | N | |
QM001877507 | The pattern was enhanced to handle the situation when there are insufficient permissions for privileged command execution. | N | |
QM001877283 | The pattern was enhanced to maintain similar naming convention for the Symantec Veritas Cluster for UNIX and Windows. | N | |
QM001877252 | The pattern now discovers JMS and JCA resources. | N | |
QM001875177 | Minor improvements. | N | |
QM001874274 | The version for webMethods Integration Server 9.x is now discovered properly. | N | |
QM001876497 | The documentation was updated with the following important information: two scans are necessary to allow BMC Atrium Discovery model all interdependent elements of Oracle Database and Oracle Real Application Clusters. | N | |
TKU-3721 | Improved versioning for Entrust GetAccess deployed on Sun Java System Webserver. | N | |
TKU-1949 | Improved key for clustered deployment. | Y | |
TKU-3768 | Improved name for BMC Capacity Optimization Application Server. | N | |
TKU-3655 | - | BMC Atrium Discovery handles the relationships with HyperSQL Databases in a better way. | N |
Defects Resolved
The following defects have been fixed in this BMC Atrium Discovery Technology Knowledge Update.
Defect No | Details | Product Page |
---|---|---|
QM001874481 | Problem: There is no visibility of the patterns where the pattern configuration block had its major revision number incremented resulting in a reset of the pattern configuration changes to the default values. Solution: Documentation update. | - |
TKU-3578 | Problem: The pattern might retrieve incorrect version. Solution: Code fix. | |
TKU-3757 | Problem: The pattern trigger condition does not account for a false positive situation. Solution: Code fix. | |
TKU-3724 | Problem: The pattern populates Software Instances name with extra information. Solution: Code fix. | |
TKU-2419 | Problem: The pattern might create an empty MongoDB Server Replication Cluster. Solution: Code fix. | |
TKU-3418 | Problem: The pattern might create a software instance with empty SI type. Solution: Code fix. | |
TKU-3733 | Problem: The pattern might generate an IBM Rational Build Forge Agent Software Instance with incorrect version. Solution: Code fix. | |
TKU-3410 | Problem: The pattern execution might cause an ECA error. Solution: Code fix. | |
TKU-3487 | Problem: The pattern uses wrong separator style when creates a server_root attribute value. Solution: Code fix. | |
QM001875626 | Problem: The pattern uses wrong separator style when creates a server_root attribute value. Solution: Code fix. | |
TKU-1399 | Problem: The pattern efficiency could be improved. Solution: Code fix. | |
QM001878047 | Problem: The pattern might extract the database detail information for Microsoft SQL Server 2012 incorrectly. Solution: Code fix. | |
QM001877260 | Problem: The pattern might create a Software Instance of incorrect type. Solution: Code fix. | |
QM001877183 | Problem: The pattern execution might cause an ECA error. Solution: Code fix. | |
QM001877293 | Problem: The pattern might not retrieve the version correctly. Solution: Code fix. | |
QM001876126 | Problem: The pattern might fail to identify the install_root value. Solution: Code fix. | |
QM001876309 | Problem: On Windows platform, the pattern might not retrieve product version correctly. Solution: Code fix. | |
QM001873032 | Problem: The pattern might fail to retrieve complete information about running instances. Solution: Code fix. | |
QM001877789 | Problem: During the CMDB sync, the relationships between virtual hosts and their related physical hosts might be deleted. Solution: Code fix. | |
QM001875626 | Problem: The pattern might not discover database details correctly. Solution: Code fix. | |
TKU-3695 | Problem: The pattern execution might cause an ECA error. Solution: Code fix. | |
TKU-3463 | Problem: The pattern might not discover the server_name, cell_name, and node_name for WebSphere Application Server SI. Solution: Code fix. | |
TKU-3503 | Problem: The pattern might not discover some versions of the BEA WebLogic Application Server. Solution: Code fix. | |
TKU-3892 | Problem: The pattern might create incorrect keys for BMC Decision Support for Server Automation Report Server. Solution: Code fix. | |
TKU-2273 | Problem: The pattern might trigger without enough evidence of the HP Data Protector Client Backup Service presence. Solution: Code fix. | |
QM001787050 | Problem: The following patterns might create SIs with non-stable key:
Solution: Code fix. | |
TKU-3771 | Problem: When the file information is created for a component triggered on a second order SI, an ECA error might happen. Solution: Code fix. | - |
TKU-3695 (Esc 071453) | Problem: The pattern execution might cause an ECA error. Solution: Code fix. | |
TKU-3183 | Problem: The pattern might discover incorrect version. Solution: Code fix. |
Configuration upgrade
In this release the following patterns have the configuration block updated:
Updating to this TKU will reset any custom configuration for these products to the default values.