View the issues in the following tables by the default sort order, Status, which shows the corrected issues first. The version number represents the update Year.Month.Release or release number (MajorRelease.MinorRelease.ServicePack.Patch) in which the issue is fixed.

Known (open) issues

 

Known and corrected installation and upgrade issues

Component

Description

Status

Found in

Defect ID

Installation and Upgrade Symptom: Discovery upgrade from 23.1 to 23.3 fails with the following error: "Inhibitor: Detected partitions mounted with the "noexec" option, preventing a successful in-place upgrade. 25.2.00 23.1.00 DRUD1-47073

Upgrade

Symptom: Upgrades fail if Baseline disk space monitoring is disabled.

24.3.0.1

22.2.00, 23.1.00, 24.1.00, 24.2.00, 24.3.00

DRUD1-50298 (DRUD1-49141, DRUD1-49872)

Upgrade

Symptom: 23.3 Upgrade fails if an invalid yum.conf file exists.

24.2.00

23.2.00

DRUD1-43258

Installation and
Upgrade

Symptom: Appliance Specification shows a false positive for DB Disk Calculation after 23.3 Upgrade.

24.1.00

23.2.00

DRUD1-42428

Installation and
Upgrade

Symptom: The tw_https_generatekey utility does not work in BMC Discovery 23.3.

24.1.00

23.3.00

DRUD1-42534

Upgrade

Symptom: Oracle Linux 9 does not support v1 architecture CPUs. Documentation fix, see Preparing-for-upgrade.

23.3.01

23.3.00

DRUD1-42641/ DRUD1-41891

Upgrade

Symptom: The upgrade fails if you have any unused disks attached.

Scope: The upgrade fails if you have any unused disks attached. An unused disk is, for example, one with no partitions defined, or one or more partitions defined and not mounted.

23.3.00.1

23.3.00

DRUD1-42351

Installation and
Upgrade

Symptom: The initial release of BMC Discovery 23.3 was not FIPS compliant, in new installations or upgrades. If you require FIPs compliance, you should upgrade to BMC Discovery 23.3 patch 1. 

23.3.00.1

23.3.00

DRUD1-42410

Known and corrected product issues

Component

Description

Status

Found in

Defect ID

Credentials

Problem: When an 11.x system with CyberArk installed is upgraded to 20.02.01, CyberArk stops functioning. An error message is displayed on the CyberArk Credential Provider tab: APPAP292E Unrecoverable error previously occurred. Avoiding approach to the Vault.

Workaround: Re-authenticate the AIM provider with the CyberArk vault.

Open

20.02.01 (12.0.0.1)

DRUD1-29491

Permissions

Problem: cmdb-export-administrator has insufficient permissions to view the export page.

Workaround: Add vault/credentials/read permission to cmdb-export-administrator.

Open

10.2.0.1, 11.0.0.0, 11.1.0.0

DRUD1-19243

Discovery

Problem: In some rare, but repeatable, cases it has been observed that performing an SNMP discovery of Juniper ERX-1440 and Cisco 6500 network devices with over 2000+ virtual interfaces might cause CPU spikes on the network device, which in extreme cases can impact switching behavior. This has only been reported by one customer, and we have confirmed other instances where discovery of the same type of devices, with similar numbers of virtual interfaces did not trigger the problem. It is therefore not possible to say precisely when this problem may be triggered. Where you are aware that the models listed above are in your discovery environment, it is advisable to perform some test scans while monitoring the CPU load on the target device prior to setting up regular scans. If you are seeing CPU load on the above devices, you can consider testing these devices once with SNMP GETNEXT method rather than default SNMP GETBULK.

Open

10.2.0.4

DRUD1-17924

TPL

Problem: A break statement in a second nested if clause of the for loop causes pattern to stop.

Open

10.1.0.0

DRUD1-16014

UI

Problem: Query builder should allow Boolean selectors for non-taxonomy attributes.

Open

10.0.0.3, 10.1.0.0

DRUD1-15724

Model

Problem: Duplicate Hosts created when scanning Linux host with SNMP and SSH using different IPs.

Open

9.0.0.0

DRUD1-14389

Discovery

Problem: Appliances with less than 16GB memory might show the Technical difficulties page when performing cloud scans, particularly when performing concurrent scans.

Workaround: Upgrade to at least 16GB if you are discovering cloud services.

Open

23.3.00

DRUD1-42092

Discovery

Problem: Currently if you discover Oracle Cloud Infrastructure (OCI) with BMC Discovery 23.3 (13.0), scan times are longer compared with previous versions of BMC Discovery.

Open

23.3.00

DRUD1-41504

Virtual appliance

Problem: Upgrading a virtual appliance on Hyper-V fails if the Hyper-V packages are still Installed on the virtual host. Note that Hyper-V is not an officially supported platform.

Workaround: Remove the Hyper-V packages before upgrading to BMC Discovery 23.3.

Open

23.3.00

DRUD1-42089

Cluster Manager  Symptom: Occasionally, a member cannot be added to a cluster after a revert to stand-alone. 25.2.00 22.2.01 DRUD1-42348 
CMDB-Sync   Symptom: Cloud Database nodes are not synchronized with ServiceNow CMDB. 25.2.00 22.2.01 DRUD1-42396 
CMDB-Sync   Symptom: CMDB Services Sync can remove relationships in Discovery while they are still present in the CMDB. 25.2.00 24.3.00 DRUD1-51175 
DataStore   Symptom: Online compaction on a multi-generational datastore should not run when only one read-only generation exists. 25.2.00 24.3.00 DRUD1-50845 
Discovery   Symptom: AssertionError in Discovery for failed SSH scan targets 25.2.00 24.3.0.1 DRUD1-51900 
Discovery   Symptom: Linux server fails with "NoAccess (Host identification failure - no mac addresses)" 25.2.00 24.2.00 DRUD1-51921 
Discovery   Symptom: The --scan-option-discover-desktops in the tw_scan_control does not work. 25.2.00 24.3.00 DRUD1-50347 
Discovery   Symptom: vCenter API does not return network interface information. 25.2.00 24.2.00 DRUD1-51282 
Documentation   Symptom: The documentation incorrectly states that "getNetworkConnectionList is not available using WMI." 25.2.00 24.2.01 DRUD1-50687 
Inferred Sync   Symptom: Receiver restart during inferred sync resync caused synced data to be destroyed. 25.2.00 25.1.00 DRUD1-51661 
Other/Unknown   Symptom: Daily Disk Usage Statistics graph is not updated after running tw_ds_compact25.2.00 22.2.00 DRUD1-38067 
Other/Unknown   Symptom: The chrony.conf file is losing some settings after modifying the NTP configuration. 25.2.00 24.3.00 DRUD1-51871 
Other/Unknown   Symptom: The license use of hosts created by BMC Helix Operations Management and BMC Helix Intelligent Integrations is unclear. 25.2.00 22.3.01 DRUD1-46557 
Reasoning   Symptom: The reasoning logs contain ecResyncCancelTasks failure messages. 25.2.00 24.3.00 DRUD1-50935 
Search  Symptom: Query function friendly_duration does not work as expected. XXX 25.2.00 24.3.00 DRUD1-51521 
Taxonomy    Symptom: The SoftwareInstance relationship role ElementUsingFile is not visible in visualizations. 25.2.00 24.3.00 DRUD1-51135 
UI  Symptom: A query generated by the Visual query builder with a "Before" condition fails to return the expected output. 25.2.00 24.4.00 DRUD1-51094 
UI  Symptom: Queries with parameters saved in "Favorite Queries" fail with "Invalid conditions". 25.2.00 24.4.00 DRUD1-51518 
UI  Symptom: While viewing a StorageSystem, the Technical difficulties page is displayed. 25.2.00 25.1.00 DRUD1-51272 
UI  Symptom: You should not be able to click the BMC Discovery Outpost credential import button multiple times. 25.2.00 24.2.02 DRUD1-50580 

Discovery

Symptom: Occasionally, the DiscoveredCommandResult.result log might contain unexpected characters.

24.3.0.1

24.2.02

DRUD1-50672 (DRUD1-49808, DRUD1-49492, DRDC1-24140, DRUD1-50314)

Discovery

Symptom: The last PowerShell and last WBEM heuristics do not include port information and do not make a connection.

 

24.3.0.1

24.2.00

DRUD1-50671 (DRUD1-50322, DRUD1-50225, DRUD1-49955)

REST API

Symptom: Deleting a Windows proxy by using the REST API does not entirely remove some proxy configuration on other cluster members.

24.3.0.1

23.3.00

DRUD1-50605 (DRUD1-50336)

Discovery

Symptom: PowerShell scanning by using an older version of the Active Directory Proxy does not work.

24.3.0.1

24.3.00

DRUD1-50400 (DRUD1-50392, DRUD1-50390)

Discovery

Symptom: Failure in session reconnect leaves a traceback in the .out file and reports UNKNOWN.

24.3.0.1

24.3.00

DRUD1-50401 (DRUD1-50393)

Service Modeling

Symptom: The direction of some relationships between nodes is shown differently in the Node and Service views.

24.3.0.1

24.4.01

DRUD1-50591 (DRUD1-50584)

Outpost

Symptom: The BMC Discovery Outpost logs workInProgress() errors.

24.3.0.1

24.3.00

DRUD1-50398 (DRUD1-49416, DRUD1-49728, DRUD1-49325, DRUD1-49543, DRUD1-49718, DRUD1-49339)

Discovery

Symptom: When discovering a Windows host by using PowerShell, a Critical error and traceback is logged.

24.3.0.1

24.2.01, 24.3.00

DRUD1-50394 (DRUD1-49714)

External Management REST API

Symptom: No response from REST API POST admin/upgrade.

24.3.00

24.3.00

DRUD1-48849

External Management REST API

Symptom: The REST API Upgrade endpoint provides no feedback when used with non-admin permissions.

24.3.00

24.3.00

DRUD1-49042

External Management REST API

Symptom: The REST API Upgrade endpoint does not distribute the upgrade package to all cluster members.

24.3.00

24.3.00

DRUD1-49239

CMDB sync

Symptom: A custom synchronization pattern fails with AttributeError: module 'cmdb_sync.functions' has no attribute 'hasSubword' during CMDB synchronization.

24.2.02

24.3.00

DRUD1-48712

Discovery

Symptom: Discovery by using SNMP occasionally fails (unable to get the deviceinfo UNKNOWN) after the May 2024 TKU update.

24.2.00.1

23.3.00

DRUD1-48803/ DRUD1-48749

CMDB sync

Symptom: While syncing to CMDB, a custom sync pattern fails with AttributeError: module 'cmdb_sync.functions' has no attribute 'hasSubword'.

24.2.00.1

24.2.02

DRUD1-48713/ DRUD1-48712

CMDB sync

Symptom: An unexpected number of CI updates occur when syncing a Host node twice.

24.2.00.1

24.2.00

DRUD1-48711/ DRUD1-48512

Consolidation

Symptom: "Request for information not part of the consolidated data" errors are logged by the Consolidator after 24.2 upgrade.

24.2.00.1

23.2.00

DRUD1-48444/ DRUD1-48442

Service and
application
modeling

Symptom: Destruction of nodes in a model causes a full model update, including when the model is in the review-suggested state.

24.2.00.1

23.3.00

DRUD1-48275/ DRUD1-48261

Discovery

Symptom: Errors reported by tw_winproxy_settings when unexpected settings are encountered.

24.2.00

24.3.00

DRUD1-47982

Discovery

Symptom: Linux hosts discovered by using BMC Discovery and those discovered from BMC Helix Operations Management can have a mismatch between MAC addresses and network interfaces, possibly resulting in duplicate hosts.

24.2.00

24.3.00

DRUD1-48254

CMDB sync

Symptom: Unexpected number of CIs updates when syncing a Host node twice.

24.2.00

24.3.00

DRUD1-48512

Reasoning

Symptom: The Contributor:Inference relationship should be deleted or updated when a Contributor package is updated.

24.2.00

22.1.01

DRUD1-40477

Discovery Outpost

Symptom: BMC Discovery Outpost SSH workers remain after a scan is finished.

24.2.00

23.1.02

DRUD1-43920

Disaster Recovery

Symptom: Disaster recovery cluster creation fails when the datastore is not in the default location.

24.2.00

22.3.01.001

DRUD1-46706

Reasoning

Symptom: FibreChannelPort and FiberChannelNode do not have a key.

24.2.00

24.1.00

DRUD1-43931

Discovery

Symptom: The JDBC embedded database drivers should be updated to the latest available version.

24.2.00

21.02.00

DRUD1-32207

Discovery

Symptom: The JDBC driver management page should be improved.

24.2.00

24.1.00

DRUD1-47083

Discovery

Symptom: SSM Setting on a scheduled Discovery Run cannot be changed to Disabled.

24.2.00

23.3.00

DRUD1-43057

Licensing

Symptom: The licensing page shows "Not Installed Storage Discovery" while Storage TKU is installed.

24.2.00

23.3.01

DRUD1-46828

CMDB sync

Symptom: Add option for Service sync in CMDB command line utility.

24.2.00

23.4.00

DRUD1-43398

Discovery Outpost

Symptom: Use the highest available cypher suites in theBMC Discovery Outpost.

24.2.00

22.2.00

DRUD1-38377

Discovery

Symptom: PowerShell discovery failure message is not helpful.

24.2.00

22.2.00

DRUD1-46439

UI

Symptom: When clicking on a host, the Discovery UI page displays: "This system is having technical difficulties with this page."

24.2.00

22.2.01

DRUD1-43579

Service and application modeling

Symptom: When changing a value in Visual Query condition builder, object Object is displayed in text field.

24.2.00

24.1.02

DRUD1-46754

UI

Symptom: Dashboard Deselect Function does not deselect the checkbox for a custom channel.

24.2.00

22.2.00

DRUD1-40019

Service and application modeling

Symptom: Creating a Service using Blueprint is not setting 'compatibility' on ModelDefinition node.

24.2.00

24.1.02

DRUD1-47415

Discovery

Symptom: Cloud detection platform script flags use ksh construct.

24.2.00

23.3.00.001

DRUD1-47499

Discovery

Symptom: Oracle SQL queries should follow the DB credential timeout.

24.2.00

22.2.00

DRUD1-39998

Discovery

Symptom: The gce_instance_name is set on some AWS Hosts.

24.2.00

23.4.00

DRUD1-43523

Reasoning 

Symptom: TPL multi-hop key expression does not reproduce semantics of previous versions.

24.2.00

24.2.00

DRUD1-47601

UI

Symptom: On CMDB timeouts, an unhelpful technical error was displayed in the UI. The error is now replaced with a simple message.

24.1.00

22.2.00.1

DRUD1-41552

UI

Symptom: You cannot bulk delete Recognition Rules, or sort rules in the UI according to Status. Controls have been added to enable you to do so. See Recognizing-SNMP-devices for more information.

24.1.00

22.2.00

DRUD1-41491

Discovery Outpost

Symptom: SinceBMC Discovery Outpost 867818, connection to the Hashicorp credential vault fails.

24.1.00

23.2.00

DRUD1-42843

External Management REST API

Symptom: The REST API did not honor maintenance mode. Any modifying (non-GET) request returns 403 Forbidden if the system is in maintenance mode.

24.1.00

22.1.01

DRUD1-42324

Discovery

Symptom: If a baseline check was run between a tw_options change and the "Updated options..." message, a TypeError exception was was raised, and the Cluster Manager required restarting. 

24.1.00

22.1.00

DRUD1-42297

UI

Symptom: A custom taxonomy causes a 'This system is having technical difficulties...' page.

24.1.00

23.1.00

DRUD1-42561

Discovery Outpost

Symptom: When the BMC Discovery Outpost released with the November TKU is installed on a FIPS enabled host, if it is not installed in the C:\ drive, the installation/upgrade does not place the fips.conf file correctly.

24.1.00

23.1.00

DRUD1-43256

UI

Symptom: HTML bold font code is visible when searching for ModelDefinitions.

24.1.00

23.3.00

DRUD1-43119

Reasoning

Symptom: External events are not sent by consolidation.

24.1.00

23.3.00

DRUD1-43342

Discovery Outpost

Symptom: BMC Discovery Outpost connection through proxy does not work until name resolution is available from the BMC Discovery Outpost.

24.1.00

23.4.00

DRUD1-43456

UI

Symptom: The tw_svc_cluster_manager.log shows security.api: WARNING: User 'xxxxxx' does not have permission for operation 'cmdb_sync'

24.1.00

23.1.00

DRUD1-42587

UI

Symptom: The title is missing on the query result list when executed from User Queries or From Favorite Queries.

24.1.00

21.05.00

DRUD1-35214

Vault

Symptom: In certain rare upgrade failures, the vault could become inaccessible. This has been corrected.

24.1.00

23.2.00

DRUD1-43484

Discovery

Symptom: Discovering Citrix NetScaler devices by using the REST API fails after installing the November TKU.

24.1.00

23.3.00

DRUD1-43492

CMDB sync

Symptom: When processing CMDB Filters, sometimes the sync will fail, and a RecursionError: maximum recursion depth exceeded error is written to the logs.

23.4.02

24.3.00

DRUD1-46967

Discovery

Symptom: When discovering an Oracle database that is using service names, the BMC Discovery Outpost cannot connect.

23.4.00

24.3.00

DRUD1-43413

Service and application modeling

Symptom: In Start Anywhere Modeling, the "Do not follow any connection" rule should include the "Management" relationship.

23.3.01

22.2.01, 23.3.00.001

DRUD1-42708/ DRUD1-42057

UI

Symptom: The sizing information was changed in the BMC Discovery 23.3 documentation, it is now reflected in the UI.

23.3.01

23.3.00

DRUD1-42693/ DRUD1-42245

Baseline

Symptom: In certain circumstances, the following Baseline error occurs: FAILED: Exception Raised: TypeError: '<=' not supported between instances of 'Any and 'int'.

23.3.01

22.1.00, 22.2, 23.1

DRUD1-42685/ DRUD1-42297

Discovery

Symptom: SSH scans using keys through the Outpost do not work since the upgrade to BMC Discovery Outpost 867818 (Sep 2023 TKU).

23.3.01

23.2.00

DRUD1-42676/ DRUD1-42631

Baseline

Problem: The appliance baseline feature uses a third-party software tool called Tripwire. The Tripwire packages are not included in the initial release of the BMC Discovery 23.3.

Workaround: To re-enable Tripwire, contact BMC Customer Support.

23.3.01

23.3.00

DRUD1-42162

Clusters

Symptom: Generating new keys by using the HTTPS Configuration page in a cluster allows you to partially apply changes.

23.3.00

24.3.00

DRUD1-42812

Netadmin

Symptom: Default gateway address is not configured after static IP address is set by using the netadmin user.

23.3.00

24.3.00

DRUD1-43063

Discovery

Symptom: You cannot perform a scan assuming all IP addresses are active, and skip pre-scanning. A new option is added in the Add a New Run dialog.

23.3.00

24.3.00

DRUD1-47363

Discovery

Symptom: Guest and ESX hosts are missing when vCenter is scanned with option "VMware Guest Scanning" enabled.

23.3.00

24.3.00

DRUD1-47940

Discovery

Symptom: Windows host names with more than 15 characters are truncated when discovered by using Powershell.

23.3.00

24.3.00

DRUD1-47963

Service and application modeling

Symptom: Destruction of nodes in a model causes a full update of the model, even if it is in the review-suggested state.

23.3.00

24.3.00

DRUD1-48261

Discovery

Symptom: Random SNMP failures (unable to get the deviceinfo UNKONWN) after May TKU/BMC Discovery Outpost update.

23.3.00

24.3.00

DRUD1-48749

Documentation

Scope: A link is displayed to a report of CIs awaiting incremental resync, though the link is not documented.

23.3.00

11.3

DRUD1-23565

Windows proxy

Symptom: Multiple processes running on the Proxy server are not being killed, resulting in the server requiring a reboot.

Workaround: Reboot the proxy server.

23.3.00

11.3.00

DRUD1-30304

Discovery

Symptom: During the discovery pre-scan phase with Nmap, many non-existent, unsupported devices were being created.

23.3.00

11.2.00.6,
11.3.00.6,
12.0.00.2,
20.08.00

DRUD1-31351

Datastore

Symptom: An excessively long query could occasionally result in the following ECA error: RuleError on rule reasoning_host_create_if_necessary.

23.3.00

20.08.01

DRUD1-31727

Discovery

Symptom: The DiscoveryRun node cannot attach to the DataSourceAccess node when a custom pattern triggers on the same DiscoveryRun node.

23.3.00

21.02.00

DRUD1-32538

CMDB sync

Symptom: CMDB resync may occasionally use excessive memory and the resync fail.

23.3.00

21.05.01

DRUD1-33393

Discovery

Symptom: The Solaris serial is not discovered when the sneep utility is not in /opt/SUNWsneep/bin.

Workaround: Modify the path on the Solaris host to include the location of the sneep utility.

23.3.00

21.3

DRUD1-36534

Outpost 

Symptom: Windows cannot start the Outpost Service.

Workaround: Keep the 'Adjust for daylight saving time automatically' setting enabled on the Outpost host date-time settings.

23.3.00

22.1.01

DRUD1-37180

Cluster

Symptom: Applying a wildcard HTTPS certificate prevents the cluster service starting after reboot.

23.3.00

22.1.01

DRUD1-37449

Outpost

Symptom: Outpost login page unresponsive after vulnerability scan using Qualys.

Workaround: Restart the Outpost service.

23.3.00

20.08.01

DRUD1-37923

Discovery

Symptom: Database discovery attempts to use disabled credentials.

Workaround: Remove the disables credentials.

23.3.00

22.2.00

DRUD1-38387

Discovery

Symptom: There is no detail within model Activity Record for some node kinds.

23.3.00

22.2.01

DRUD1-38847

Discovery

Symptom: Windows package names can contain garbage characters.

23.3.00

20.08.00

DRUD1-38879

UI

Symptom: Where scans contain very many, links might be generated and displayed that are too long to be served in the UI.

23.3.00

22.1.01

DRUD1-39226

Discovery

Symptom: The token for the Thycotic Secret Server credential broker expires after 20 minutes leading to scan failures.

23.3.00

21.3.00

DRUD1-39596

Credentials

Symptom: Unable to load credentials when the Enter key is used instead of the Apply button when creating or editing a credential in the BMC Discovery Outpost.

Workaround: Use the Apply button in the UI when creating credentials in the BMC Discovery Outpost.

23.3.00

21.05.00,
22.4.00

DRUD1-39597

Logging

Symptom: Audit Log did not record login failure for user without correct permission.

23.3.00

22.2.00

DRUD1-39641

Discovery

Symptom: The tw_proxy_register utility cannot register an existing proxy with another appliance.

23.3.00

22.2.01

DRUD1-39798

Discovery

Symptom: Occasionally Amazon Web Services fails with the ECA error, inference is None in InferenceKeyMaintainer.extract_keys().

23.3.00

22.2.00

DRUD1-39802

Discovery

Symptom: Deep discovery of VMware Guest Hosts performs unnecessary implicit scans of the vCenter guest.

23.3.00

22.2.00.1

DRUD1-39805

Credentials

Symptom: PowerShell credential failures are not recorded in the UI Session Result List.

23.3.00

22.1.00

DRUD1-39829

Discovery

Symptom: Discovery of OpenVMS using ssh from the BMC Discovery Outpost fails.

23.3.00

23.1.00

DRUD1-39902

Discovery

Symptom: Explicit and Implicit scans of the same endpoint result in a successful and an unsuccessful scan linked to the Discovery Access.

23.3.00

23.1.00

DRUD1-40107

Discovery

Symptom: vCenter polling can stop when the SI starts to age.

23.3.00

23.1.00

DRUD1-40114

UI

Symptom: The Host node view page shows a table of network interfaces and their IP addresses. If there are no network interfaces, no IP address information is shown.

23.3.00

23.1.00

DRUD1-40243

Discovery

Symptom: Discovery Run errors are shown on LPARs when a Job Name is not reported.

23.3.00

22.2.00

DRUD1-40268

Credentials

Symptom: You cannot extract DOMAIN from Cyberark from an arbitrary attribute. See Using-CyberArk-credentials-for-discovery for more information on this resolved defect.

23.3.00

11.3

DRUD1-40301

Consolidation

Symptom: Recent run in Consolidator shows an error regarding "Outpost no longer registered".

23.3.00

23.1.00

DRUD1-40320

Outpost

Symptom: The BMC Discovery Outpost automatic update occasionally fails resulting in a BMC Discovery Outpost that can no longer connect to BMC Helix Discovery. The installation failure is not logged.

Workaround: Perform a manual update of the BMC Discovery Outpost.

23.3.00

22.1.01

DRUD1-40329

CMDB sync

Symptom: The last_discovered attribute should be set when a destroyed node is synced to ServiceNow CMDB.

23.3.00

22.1.00

DRUD1-40421

Model

Symptom: SIs hosted on MFParts do not age correctly.

23.3.00

23.1.00

DRUD1-40594

Documentation

Scope: The Discovering-VMware-guest-hosts-by-using-the-vCenter-API topic does not mention of VMware tool requirement.

23.3.00

23.1.00

DRUD1-40868

Documentation

Scope: The PRIV_LSHW privileged command was not documented.

23.3.00

23.1.00

DRUD1-40899

Modeling

Symptom: You cannot use Google Chrome or Microsoft Edge to export a SAM model definition if there is a comma in the name.

Workaround: Use the Firefox browser or edit the model definition name.

23.3.00

22.2.01

DRUD1-40900

Key generation

Symptom: Cannot generate a new key when the company name is too long.

23.3.00

23.1.00

DRUD1-40932

Discovery

Symptom: Intermittent inconsistent Kerberos scan failures occur in a cluster (in time, and by member) after upgrade from 22.2.0.2 to 23.1.0.1.

23.3.00

22.2.0.2

DRUD1-40935

Documentation

Scope: Documentation error in the tw_pattern_management topic.

23.3.00

23.1.01

DRUD1-41221

TPL

Symptom: The discovery.getCertificate() TPL function does not handle timeouts correctly.

23.3.00

23.1.00

DRUD1-41408

Credentials

Symptom: If you add a comma separated IP address with line breaks in Matching criteria or Matching exceptions, and you do not use the text view toggle, you cannot test the credential.

Workaround: Avoid line breaks in a list of IP addresses of you are pasting them into the IP Address field.

23.3.00

23.1.02

DRUD1-41505

UI

Symptom: The visualization screen times out when displaying Storage in the infrastructure focus.

23.3.00

23.1.00

DRUD1-41803

Appliance

Symptom: The Appliance Specification shows a false positive for DB Disk Calculation after upgrading to BMC Discovery 23.3.

23.2.00

24.3.00

DRUD1-42428

Consolidation

Symptom: "Request for information not part of the consolidated data" error is seen on the Consolidator after upgrading to BMC Discovery 24.2.

23.2.00

24.3.00

DRUD1-48442

Outpost

Symptom: The BMC Discovery Outpost can leave child Java processes after running SQL queries.

23.1.00

24.3.00

DRUD1-42656

CMDB sync

Symptom: If a ServiceNow CMDB sync connection times out, it can cause cluster problems.

23.1.00

24.3.00

DRUD1-43073

Discovery

Symptom: SSM connections do not honour the TLS certification check setting in the AWS credential.

23.1.00

24.3.00

DRUD1-46701

Discovery

Symptom: Expired Kerberos credentials can block good scans with 30 min timeouts.

22.3.00

24.3.00

DRUD1-47007

Discovery

Symptom: Discovery requests against Hosts that were not created by session-based access can fail and result in errors.

22.1.00.1

24.3.00

DRUD1-37370

Netadmin

Symptom: The netadmin user does not support defining a static IPv6 address.

21.05.00

24.3.00

DRUD1-33709

Backup 

Symptom: Encrypted backups cannot be restored by using the tw_restore utility.

Workaround: Use the UI to restore backups

 

23.3.00

DRUD1-42091

 