Integrating with CA UIM


As a tenant administrator, it's important that you can monitor the connected systems and quickly identify and resolve any issues. The BMC Helix Intelligent Integrations CA UIM connector collects alarms and metrics data from CA UIM .

You can view the collected data in various BMC Helix application and derive the following benefits:

BMC Helix application

Type of data collected or viewed

Benefits

BMC Helix Operations Management

Events (from CA UIM ) alarms

Use a centralized event view to monitor, filter, and manage events, and perform event operations in one place. 

Process events to help identify actionable events quickly from a large volume of event data.

For more information, see  Monitoring events and reducing event noise.

BMC Helix Operations Management

Metrics

Use alarm and variate policies to detect anomalies and eliminate false positives for more accurate results while monitoring the health of your system.

For more information, see Detecting anomalies by using static and dynamic thresholds.

BMC Helix AIOps

Situations (created from events)

Improve the mean time to resolve (MTTR) based on the situation-driven workflow.

Lower the mean time to detect or discover (MTTD) and the time required for investigating tickets.

For more information, see Monitoring situations.

BMC Helix Dashboards

Events and metrics

Create dashboards to get a consolidated view of data collected from third-party products across your environment. 

Improve the efficiency of your system by monitoring the key performance metrics and r espond to issues quickly to minimize the down time.

For more information, see Creating custom dashboards


As a tenant administrator, perform the following steps to configure a connection with CA UIM , verify the connection, and view the collected event and metric data in various BMC Helix applications.

Connector steps.png


Supported versions

This connector supports version 20.3.3 of CA UIM  for data collection:

Planning for the connection

Review the following prerequisites to help you plan and configure a connection with CA UIM.

CA UIM prerequisites

Ensure that you have the following permissions to access CA UIM REST API: 

  • Alarm Details
  • Basic Management
  • Web Service

BMC Helix Intelligent Integrations prerequisites

  • Depending on the location (SaaS, on-premises) of the third-party product, choose one or more BMC Helix Intelligent Integrations deployment modes and review the corresponding port requirements. For information about various deployment modes and port requirements, see Deployment-scenarios.
  • Based on the deployment modes, use the BMC Helix Intelligent Integrations SaaS deployment or the BMC Helix Intelligent Integrations on-premises gateway or both. For more information about the gateway, see Deploying-the-BMC-Helix-Intelligent-Integrations-on-premises-gateway.
  • The on-premises gateway must be able to reach the third-party product on the required port (default is 80).

In the preceding list, third-party product refers to CA UIM.

Configuring the connection with CA UIM

  1. Access BMC Helix Intelligent Integrations:
    • BMC Helix Intelligent Integrations SaaS – Log on to BMC Helix Portal, and click Launch on BMC Helix Intelligent Integrations.
    • BMC Helix Intelligent Integrationson-premises gateway – Use one of the following URLs to access BMC Helix Intelligent Integrations:
      • http://<hostName>:<portNumber>/swpui
      • https://<hostName>:<portNumber>/swpui
  2. On the CONNECTORS tab, clickadd_icon.png in the SOURCES panel.
  3. Click the CA UIMtile.
  4. Specify the following details for the source connection:
    1. Specify a unique instance name.

      Best practice
      We recommend that you specify the instance name in the following format: 

      <sourceType>_<sourceControllerServerName>{_<InstanceQualifier>}

      The instance qualifier helps you to distinguish the multiple instances configured from the same source server. For example, you can name your instances as CAUIM_Host_PROD, CAUIM_Host_TEST, and so on.

    2. Specify the CA UIM host name.
    3. Specify the CA UIM HTTP or HTTPS port number depending on the connection protocol (default port number is 80).
    4. Select the HTTPS option to use an https connection to the CA UIM host.
    5. Enter the user name and password for the CA UIM host.
    6. Specify the time, in seconds, after which no attempt should be made to establish the connection (default value is 30 seconds).
    7. Click Proxy and specify whether you want to configure a proxy server.
      If yes, specify the host name and port number (default value is 8888).
  1. Click VALIDATE AND CREATE.
    The specified connection details are validated and the corresponding source connection is created in the Source Connection list.
  2. Select the source connection that you created from the list if it is not selected already.

    Important

    The destination host connection is created and configured automatically when the source connection is created.

  3. Ensure that the options for the datatypes for which you want to collect data are selected.
  4. Configure the collectors for the selected data types by clicking the respective data type in the Collectors section. Specify the parameters for the selected data type, as explained in the following table:

    Note: The ✅️  symbol indicates that this field is applicable to the data type.

  5. Click CREATE COLLECTORS to create the required collector streams for the selected data types.
  6. Configure the distributors for the selected data types by clicking the respective data type in the Distributors section.
    Specify the parameters for the selected data type, as explained in the following table:
  1. Click CREATE DISTRIBUTORS to create the required distributor streams for the selected data types.
  2. Click one of the following buttons:
    • SAVE STREAM : Click this button if you want to edit the integration details before creating the instance. After you save the stream, the connector that you just created is listed in the SOURCES panel. Move the slider to the right to start the data stream.
    • SAVE AND START STREAM : Click this button if you want to save the integration details and start receiving data immediately.

          For more information about the data streams, see Starting-or-stopping-data-streams.


Verifying the connection

From BMC Helix Intelligent Integrations , on the SOURCES panel, confirm that the data streams for the connection you created are running. Data streaming is indicated by moving colored arrows.

CA_UIM_Streams_232.png

  • A moving blue arrow ( EventsStream_Icon.png) indicates that the event stream is running. Event data will be pushed according to the configured Collection Schedule interval.
  • A moving red arrow (MetricsStream_Icon.png ) indicates that the metric stream is running. Metric data will be pushed according to the configured Collection Schedule interval.

Viewing data in BMC Helix applications

View data collected from CA UIM in multiple BMC Helix applications.

Important

If the event or metric data is ingested by using BMC Helix Intelligent Integrations, and the topology data is ingested through some other means, all the use cases in BMC Helix AIOps might not work as expected because the external IDs generated by BMC Helix Intelligent Integrations and BMC Helix Discovery differ. In addition, host name might differ in both the products. 

To view events in BMC Helix Operations Management

  1. In BMC Helix Operations Management, select Monitoring > Events.
  2. Filter the events by the CA_UIM_Alarm class.
    CAUIM_Events.png

Incoming events from CA UIM are processed in BMC Helix Operations Management through a set of deduplication rules to determine whether the incoming event is a duplicate event or a new event. For more information, see Event-deduplication-and-suppression-for-reducing-event-noise.

For more information about events, see Monitoring and managing events.

To view metrics in BMC Helix Operations Management

  1. In BMC Helix Operations Management, select Monitoring > Devices.
  2. Click the links for the required device.
  3. On the Monitors tab, click the required monitor.
    The Performance Overview tab shows the metrics graph.

    CAUIM_Metrics_232.png

For information about metrics, see Viewing collected data.

Viewing Situations in BMC Helix AIOps

Before you view situations in BMC Helix AIOps, ensure that the following prerequisites are met: 

  1. CIs are present in BMC Helix Discovery or BMC Helix AIOps for the events that are being collected from CA UIM .
  2. Create a Business Service model in one of the following applications:
  3. Perform one of the following tasks:

To view Situations

  1. In BMC Helix AIOps , go to the Situations page.
    This page shows the Situations created from the events that are ingested into BMC Helix Operations Management . 
  2. Click the required Situation to view the messages contained in the Situation and other details such as priority and severity of the message. 

For information about Situations, see Monitoring situations.

Mapping between CA UIM and BMC Helix Operations Management

The following table shows the mapping between CA UIM and BMC Helix Operations Management:

Event attribute

CA UIM

BMC Helix Operations Management

Status

Closed

Closed

Open

Open

Severity

Critical

Critical

Info

Info

Minor 

Minor

Major

Major

Warning

Warning

Title

Title

Message

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*