Important This space contains documentation for TrueSight Smart Reporting for Server Automation 20.02.01. For earlier releases, see TrueSight Smart Reporting for Sever Automation 19.2.

Changing the TrueSight Smart Reporting details


When TrueSight Smart Reporting - Platform host name or IP address changes, you must update the host name or IP address in TrueSight Server Automation - Data Warehouse

Do the following:

  1. Connect to the TrueSight Server Automation - Data Warehouse database as the data warehouse database user.
  2. In the System_property table, update the host name or IP address by executing the following query:

    update system_property

    SET VALUE = 'https://<changed hostname or IP>:<port>/'

    WHERE NAME = 'ReportingURL'

    where <changed hostname or IP >  is the updated host name or IP address  for TrueSight Smart Reporting - Platform, and <port> is the port number where TrueSight Smart Reporting - Platform is installed.

  3. Commit the database changes.
  4. Restart the TrueSight Server Automation - Data Warehouse service.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*