Custom properties


After you upgrade to TrueSight Smart Reporting - Platform 19.3 and TrueSight Server Automation - Data Warehouse 8.9.04.003 and run the ETL, you will not see the newly added custom properties due to known issue DRSOD-1528.

Resolution

To view these custom properties, do the following:

  1. After the ETL runs successfully, navigate to the following path:
    <TSSA-DWInstallationDirectory>/shared/odi/bin
  2. At the command prompt, run the following command:
    nsh update_custom_property.nsh
    After the command is run successfully, the newly added custom properties are imported into TrueSight Smart Reporting - Platform. 

If you encounter any issues, check the update_custom_property.log at the following path:

<TSSA-DWInstallationDirectory>/logs/update_custom_property/etl/<timestamp_folder>

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*