Messages BMC9700 through BMC9799 (BMC system administration family of products for IMS)
Number | Description |
---|---|
BMC9767E | OPEN FAILED FOR DDname DDname Explanation: An OPEN failed for the indicated ddname, which is a STEPLIB. The OPEN probably failed because of a missing DD statement. The IMS control region terminates with abend U4061. User response: Ensure that the IMS system procedure contains a valid STEPLIB or DD statement. |
BMC9768E | FIND FAILED FOR LOAD MODULE module Explanation: The load module could not be found in the data set to which the STEPLIB pointed. The IMS control region terminates with abend U4061. User response: Ensure that the IMS system procedure contains a valid STEPLIB with the appropriate pointers. |
BMC9769E | MODULE module NOT LOADED Explanation: The load module was not loaded into the IMS system control region. Failure to load probably occurred because of a logic error. The IMS control region terminates with abend U4061. User response: Determine the reason for the load failure. If necessary, contact BMC Customer Support. |
BMC9770E | CSECT csect module NOT LOCATED Explanation: The named csect was not found in the load module. Failure to load probably occurred because of a logic error. The IMS control region terminates with abend U4061. User response: Contact BMC Customer Support. |
BMC9771E | ADDRESS VERIFY FAILED: CSECT addressSpace module Explanation: An attempt to locate the CSECT addressspace within the load module failed. This failure probably occurred because of a logic error. The IMS system control region terminates with abend U4061. User response: Obtain the IMS system job log and SYSUDUMP listings and contact BMC Customer Support. |
BMC9781E | IMODULE LOAD FAILED FOR module Explanation: An attempt to load the initialization module failed. The module should have been in the IMS system RESLIB. Message Advisor initialization terminates; IMS system initialization continues. User response: Ensure that all required modules are available to the IMS control region through either the STEPLIB or MVS LNKLST. |
BMC9782E | controlName CTL NOT SET Explanation: The Message Advisor initialization fails. Look for additional BMC messages; they will provide more explanation for this failure. Message Advisor initialization terminates; IMS system initialization continues. User response: Ensure that all required modules are in the proper libraries and restart IMS. |
BMC9783E | INTERCEPT APPLICATION FAILED - ABEND U4061 Explanation: Message Advisor cannot locate an intercept point that is required to complete initialization. The IMS control region terminates with abend U4061. User response: Contact BMC Customer Support. |
Comments
Log in or register to comment.