Installing iCap distributed alarms

This topic was edited by a BMC Contributor and has not been approved.  More information.

iCap ships distributed alarms in HLQ.BBACTDEF. To use the alarms, you must add them to the alarm-definition file system. Use the following procedure.

To install distributed alarms

  1. Concatenate the BBACTDEF library to your iCap master PAS.

  2. In iCap, type ALRMDIST on the COMMAND line and press Enter.

    The ALRMDIST view lists the iCap distributed alarms:

    For a list of alarms, see Descriptions of distributed alarms.

  3. To install new alarms or reinstall existing alarms:

    1. Type A or ADD in the CMD column beside each alarm that you want to install or reinstall.

    2. (If reinstalling alarms) Specify REPLACE YES.

    3. Press Enter.

  4. In PLEXMGR, access the AMD view.
    On AMD, you can review all of the alarms that are installed for iCap.

    If needed, you can use MainView Alarm Management to customize the distributed alarm definitions to meet your monitoring needs; you can also create your own alarms by using the MAKEAlarm line command. For more information, see Using MainView Alarm Management. Open link


  5. To activate an alarm, type ACT in the CMD field next to the alarm name.

    Note

    If the iCap master PAS moves to a new system, you must make provisions to use the distributed alarms. 

Descriptions of distributed alarms

The following table describes the iCap distributed alarms

AlarmDescriptionBased on this column

DYC4HR00

The 4HRA for an LPAR or group has exceeded the assigned DC or GCL.

4HRA %DCGCL column for the *Policy row of the POLOVER view

DYC4HR01

The 4HRA for an LPAR has exceeded the assigned DC or GCL.

4HRA %DCGCL column for individual LPARs on the SUBPOLO view

DYCLIW00The low importance workload percent is less than 5.

Low-Imp Wkld% column for individual LPARs and groups on the POLOVER view

When critical work is at risk for an LPAR or group, iCap triggers the alarm and highlights the Low-Imp Wkld% value in yellow.

DYCLIW01The low importance workload percent is 0.

Low-Imp Wkld% column for individual LPARs and groups on the POLOVER view

When critical work is at risk for an LPAR or group, iCap triggers the alarm and highlights the Low-Imp Wkld% value in red.

DYCLIW02The low importance workload percent is 5, and the MSU limit percent is 100.

Low-Imp Wkld% and % MSU Limit columns for the *Policy row of the POLOVER view

When critical work is at risk for an LPAR or group, iCap triggers the alarm and highlights the Low-Imp Wkld% and % MSU Limit values in yellow.

DYCLIW03The low importance workload percent is 0, and the MSU limit percent is 100.

Low-Imp Wkld% and % MSU Limit columns for the *Policy row of the POLOVER view

When critical work is at risk for an LPAR or group, iCap triggers the alarm and highlights the  Low-Imp Wkld% and % MSU Limit values in red.

DYCLIW04

The DC or GCL of an LPAR or group reaches MAX DC/GCL.

MIN(4HRA, DC | GCL) column for individual LPARs and groups on the POLOVER view

When critical work is at risk for an LPAR or group, iCap triggers the alarm and highlights the MIN(4HRA, DC | GCL) , iCap triggers the alarm and highlights thein red.

DYCLIW05

The low importance workload percent is 5.

Low-Imp Wkld% column for individual LPARs on the SUBPOLO view

When critical work is at risk for an LPAR, iCap triggers the alarm and highlights the Low-Imp Wkld% value in yellow.

DYCLIW06

The low importance workload percent is 0.

Low-Imp Wkld% column for individual LPARs on the SUBPOLO view

When critical work is at risk for an LPAR, iCap triggers the alarm and highlights the Low-Imp Wkld% value in red.

DYCLIW07

The low importance workload percent is 5, and the MSU limit percent is 100.

Total Low-Imp Wkld% and % MSU Limit columns for the *Policy row on the SUBPOLO view

When critical work is at risk for an LPAR in the subpolicy, iCap triggers the alarm and highlights the Low-Imp Wkld% and the % MSU Limit values in yellow.

DYCLIW08

The low importance workload percent is 0, and the MSU limit percent is 100.

Total Low-Imp Wkld% and % MSU Limit columns for the *Policy row on the SUBPOLO view

When critical work is at risk for an LPAR in the subpolicy, iCap triggers the alarm and highlights the Low-Imp Wkld% and the % MSU Limit values in yellow.

DYCLIW09

The DC or GCL of an LPAR reaches MAX DC/GCL.

%M4DCGCL MAXDCGCL column for individual LPARs on the POLOVER view

When critical work is at risk for an LPAR, iCap triggers the alarm and highlights the %M4DCGCL MAXDCGCL value in red.

DYCMOMX1

(PTF BQY2177 applied)

The monthly MSU limit equals or exceeds 100% of the maximum MSU limit

%MonthlyMSULIMITMaxMSULIMIT column on the POLOVER view

DYCMOMX2

(PTF BQY2177 applied)

The monthly MSU limit equals or exceeds 100% of the maximum MSU limit%MonthlyMSULIMITMaxMSULIMIT column on the SUBPOLOVER view

DYCMSL00

The combined 4HRA equals or exceeds 98% of MSU limit

% MSU Limit column for the *Policy row of the POLOVER view

DYCMSL01

The combined 4HRA equals or exceeds 95% of MSU limit

% MSU Limit column for the *Policy row of the POLOVER view

DYCMSL02

The combined 4HRA equals or exceeds 85% of MSU limit

% MSU Limit column for the *Policy row of the POLOVER view

DYCMSL03

The combined 4HRA equals or exceeds 98% of MSU limit

% MSU Limit column for the *Policy row of the SUBPOLO view

DYCMSL04

The combined 4HRA equals or exceeds 95% of MSU limit

% MSU Limit column for the *Policy row of the SUBPOLO view

DYCMSL05

The combined 4HRA equals or exceeds 85% of MSU limit

% MSU Limit column for the *Policy row of the SUBPOLO view

DYCCMSU0

The MSU usage for a CPC equals or exceeds 85% of CPCMSU limit.

%CPCMSU field in the MULTIPLEX view

When critical work is at risk for a Multiplex CPC, iCap triggers the alarm and highlights the %CPCMSU value in yellow.

DYCCMSU1

The MSU usage for a CPC equals or exceeds 95% of CPCMSU limit.

%CPCMSU field in the MULTIPLEX view

When critical work is at risk for a Multiplex CPC, iCap triggers the alarm and highlights the %CPCMSU value in red.

DYCCMSU2

The MSU usage for a CPC equals or exceeds 98% of CPCMSU limit.

%CPCMSU field in the MULTIPLEX view

When critical work is at risk for a Multiplex CPC, iCap triggers the alarm and highlights the %CPCMSU value in red.