Installing iCap distributed alarms
iCap
ships distributed alarms in HLQ.BBACTDEF. To use the alarms, you must add them to the alarm-definition file system. Use the following procedure.
To install distributed alarms
- Concatenate the BBACTDEF library to your iCap master PAS.
In iCap, type ALRMDIST on the COMMAND line and press Enter.The ALRMDIST view lists the iCap distributed alarms:
For a list of alarms, see Descriptions of distributed alarms.
- To install new alarms or reinstall existing alarms:
- Type A or ADD in the CMD column beside each alarm that you want to install or reinstall.
- (If reinstalling alarms) Specify REPLACE YES.
- Press Enter.
In PLEXMGR, access the AMD view.
On AMD, you can review all of the alarms that are installed for iCap.If needed, you can use MainView Alarm Management to customize the distributed alarm definitions to meet your monitoring needs; you can also create your own alarms by using the MAKEAlarm line command. For more information, see Using MainView Alarm Management.
To activate an alarm, type ACT in the CMD field next to the alarm name.
Descriptions of distributed alarms
The following table describes the iCap distributed alarms
Alarm | Description | Based on this column |
---|---|---|
DYC4HR00 | The 4HRA for an LPAR or group has exceeded the assigned DC or GCL. | 4HRA %DCGCL column for the *Policy row of the POLOVER view |
DYC4HR01 | The 4HRA for an LPAR has exceeded the assigned DC or GCL. | 4HRA %DCGCL column for individual LPARs on the SUBPOLO view |
DYCLIW00 | The low importance workload percent is less than 5. | Low-Imp Wkld% column for individual LPARs and groups on the POLOVER view When critical work is at risk for an LPAR or group, iCap triggers the alarm and highlights the Low-Imp Wkld% value in yellow. |
DYCLIW01 | The low importance workload percent is 0. | Low-Imp Wkld% column for individual LPARs and groups on the POLOVER view When critical work is at risk for an LPAR or group, iCap triggers the alarm and highlights the Low-Imp Wkld% value in red. |
DYCLIW02 | The low importance workload percent is 5, and the MSU limit percent is 100. | Low-Imp Wkld% and % MSU Limit columns for the *Policy row of the POLOVER view When critical work is at risk for an LPAR or group, iCap triggers the alarm and highlights the Low-Imp Wkld% and % MSU Limit values in yellow. |
DYCLIW03 | The low importance workload percent is 0, and the MSU limit percent is 100. | Low-Imp Wkld% and % MSU Limit columns for the *Policy row of the POLOVER view When critical work is at risk for an LPAR or group, iCap triggers the alarm and highlights the Low-Imp Wkld% and % MSU Limit values in red. |
DYCLIW04 | The DC or GCL of an LPAR or group reaches MAX DC/GCL. | MIN(4HRA, DC | GCL) column for individual LPARs and groups on the POLOVER view When critical work is at risk for an LPAR or group, iCap triggers the alarm and highlights the MIN(4HRA, DC | GCL) , iCap triggers the alarm and highlights thein red. |
DYCLIW05 | The low importance workload percent is 5. | Low-Imp Wkld% column for individual LPARs on the SUBPOLO view When critical work is at risk for an LPAR, iCap triggers the alarm and highlights the Low-Imp Wkld% value in yellow. |
DYCLIW06 | The low importance workload percent is 0. | Low-Imp Wkld% column for individual LPARs on the SUBPOLO view When critical work is at risk for an LPAR, iCap triggers the alarm and highlights the Low-Imp Wkld% value in red. |
DYCLIW07 | The low importance workload percent is 5, and the MSU limit percent is 100. | Total Low-Imp Wkld% and % MSU Limit columns for the *Policy row on the SUBPOLO view When critical work is at risk for an LPAR in the subpolicy, iCap triggers the alarm and highlights the Low-Imp Wkld% and the % MSU Limit values in yellow. |
DYCLIW08 | The low importance workload percent is 0, and the MSU limit percent is 100. | Total Low-Imp Wkld% and % MSU Limit columns for the *Policy row on the SUBPOLO view When critical work is at risk for an LPAR in the subpolicy, iCap triggers the alarm and highlights the Low-Imp Wkld% and the % MSU Limit values in yellow. |
DYCLIW09 | The DC or GCL of an LPAR reaches MAX DC/GCL. | %M4DCGCL MAXDCGCL column for individual LPARs on the POLOVER view When critical work is at risk for an LPAR, iCap triggers the alarm and highlights the %M4DCGCL MAXDCGCL value in red. |
DYCMOMX1 (PTF BQY2177 applied) | The monthly MSU limit equals or exceeds 100% of the maximum MSU limit | %MonthlyMSULIMITMaxMSULIMIT column on the POLOVER view |
DYCMOMX2 (PTF BQY2177 applied) | The monthly MSU limit equals or exceeds 100% of the maximum MSU limit | %MonthlyMSULIMITMaxMSULIMIT column on the SUBPOLOVER view |
DYCMSL00 | The combined 4HRA equals or exceeds 98% of MSU limit | % MSU Limit column for the *Policy row of the POLOVER view |
DYCMSL01 | The combined 4HRA equals or exceeds 95% of MSU limit | % MSU Limit column for the *Policy row of the POLOVER view |
DYCMSL02 | The combined 4HRA equals or exceeds 85% of MSU limit | % MSU Limit column for the *Policy row of the POLOVER view |
DYCMSL03 | The combined 4HRA equals or exceeds 98% of MSU limit | % MSU Limit column for the *Policy row of the SUBPOLO view |
DYCMSL04 | The combined 4HRA equals or exceeds 95% of MSU limit | % MSU Limit column for the *Policy row of the SUBPOLO view |
DYCMSL05 | The combined 4HRA equals or exceeds 85% of MSU limit | % MSU Limit column for the *Policy row of the SUBPOLO view |
DYCCMSU0
| The MSU usage for a CPC equals or exceeds 85% of CPCMSU limit. | %CPCMSU field in the MULTIPLEX view When critical work is at risk for a Multiplex CPC, iCap triggers the alarm and highlights the %CPCMSU value in yellow. |
DYCCMSU1 | The MSU usage for a CPC equals or exceeds 95% of CPCMSU limit. | %CPCMSU field in the MULTIPLEX view When critical work is at risk for a Multiplex CPC, iCap triggers the alarm and highlights the %CPCMSU value in red. |
DYCCMSU2
| The MSU usage for a CPC equals or exceeds 98% of CPCMSU limit. | %CPCMSU field in the MULTIPLEX view When critical work is at risk for a Multiplex CPC, iCap triggers the alarm and highlights the %CPCMSU value in red. |
Related topic