You can define range-based thresholds for the attributes of a monitor type or an instance on the PATROL Agents.
This topic covers the following tasks:
Character | Expression | Description |
---|---|---|
^ | Beginning of line | Only finds the search term if the term is at the beginning of a line |
$ | End of line | Only finds the search term if the term is at the end of a line |
. | Any character | Matches any single character except a line break |
* | Zero or more | Matches zero or more occurrences of the preceding expression, making all possible matches |
[] | Any one character in the set | Matches any one of the characters within the []. To specify a range of characters, list the starting and ending characters, separated by a dash (-), as in [a-z]. |
[^] | Any one character not in the set | Matches any character not in the set of characters following the ^ |
\< | Beginning of word | Matches only when a word begins at this point in the text |
\> | End of word | Matches only when a word ends at this point in the text |
If you want to identify the SID of a specific monitor instance, perform the following tasks:
If you have not done so already, perform the steps provided under the following sections:
In the Add Agent Threshold Configuration dialog box, select IT Data Analytics as Monitoring Solution, 2.1.00 as version.
Select one of the following Monitor Type:
If you have selected Instance as the scope, in the Instance SID box, type the instance SID of the monitor type.
Note
You can also use regular expressions to search for multiple matching instance SIDs. If you use regular expressions to search for the matching instance SIDs, ensure that you have selected Is a Regular Expression.
In the Attribute list, select a monitor attribute.
Note
In the Attribute list, some attributes are designated as key performance indicators (KPIs). Depending on the monitored environment and version, the list of KPIs might appear differently in the ProactiveNet Operations Console.
In the Min and Max lists, set the minimum and maximum values for the range.
Note
If you plan to configure alarm 1 range, the minimum value of the border range must be less than or equal to the minimum value of the alarm 1 range. If you plan to configure alarm 2 range, the maximum value of the border range must be greater than or equal to the maximum value of the alarm 2 range.
If you want to configure alarm 1 range, under Alarm 1, select Enable, and perform step a through step c.
Note
If you have configured border range, the minimum value of the alarm 1 range must be greater than or equal to the minimum value of the border range. If you plan to configure alarm 2 range, the maximum value of the alarm 1 range must be less than or equal to the minimum value of the alarm 2 range.
If you want to configure alarm 2 range, under Alarm 2, select Enable, and perform step a through step c.
If you have configured alarm 1 range, the minimum value of the alarm 2 range must be greater than or equal to the maximum value of the alarm 1 range. If you plan to configure border range, the maximum value of the alarm 2 range must be less than or equal to the maximum value of the border range.
After you save or update a policy, the new threshold configurations are pushed to the selected PATROL Agents.
After you update a policy, the updated threshold configurations are pushed to the selected PATROL Agents.
You can delete the threshold configuration based on the monitoring solutions, versions, monitor types, or attributes.
After you delete an agent threshold configuration and save the policy, the deleted threshold configurations are removed from the selected PATROL Agents.