After completing the Presentation Server upgrade with the upgrade wizard or through silent upgrade, you can verify that the Presentation Server was upgraded successfully and is operating. You can verify this by reviewing the log entries added during the upgrade, and examining the server processes and services.
Access the truesightpserver_install_log.txt file, which is located in the (Windows) C:\Users\Administrator\AppData\Local\Temp directory or (Linux) /tmp directory.
Note
For the fix pack1 upgrade, truesightpserver_fixpack_log.txt file is created. This file is located in the C:\Users\Administrator\AppData\Local\Temp directory.
Post upgrade, to verify that the Presentation Server is operating, navigate to the (Windows) TrueSightPServer\truesightpserver\bin or (Linux) TrueSightPServer/truesightpserver/bin directory and run the following command:
(Windows) tssh server status
(Linux) ./tssh server status
A list of Presentation Server processes is displayed that is similar to the following sample:
Process status
================================
Core Server Running (13176)
Index Server Running (11028)
Database Server Running (6052)
If errors occur, restart the Presentation Server by running the following command:
(Windows) tssh server start
(Linux) ./tssh server start &
Note
On Linux computers, add &
at the end of the tssh server start
command so that the process runs in the background and you can continue to use the shell.