Setting up a CMDB synchronization connection
This topic provides instructions for configuring synchronization from BMC Discovery to one or more instances of BMC CMDB, and a Remedyforce CMDB.
Before you begin
Before you can synchronize from BMC Discovery to any instance of BMC CMDB, you must have prepared that CMDB. For a Remedyforce CMDB, you do not have to prepare the CMDB, though you do have to create a connected application in Remedyforce. See the Remedyforce documentation for more information.
CMDB synchronization and clusters
When configuring CMDB synchronization from a cluster, you can use any machine for the initial configuration and subsequent updates. All data synchronized to any connected BMC CMDB is sent from the coordinator.
Note
Do not change the CMDB synchronization configuration at the same time that you change the cluster configuration.
- Changing the CMDB sync configuration means adding connections, removing connections, and starting or stopping a resync.
- Changing the cluster configuration means adding members, removing members, moving the coordinator, or changing fault tolerance.
To configure a CMDB synchronization connection
- Log in to BMC Discovery.
- From the main menu, click the Administration icon .
The Administration page displays. - From the Model section, click CMDB Sync .
If no CMDB Sync has been configured, a banner displays stating that no CMDB Sync connections are configured. - Click Add CMDB Connection to add and configure a new connection.
- Enter the required details on the Add CMDB Connection page. For more information about the connection details, see Connection details.
- Click Test Connection to verify that the new connection can be reached and the credentials are valid. Testing the connection also retrieves the list of companies from the CMDB for connections other than Remedyforce.
Connection details
Enter the following details on the Add CMDB Connection page.
Connection name
Field | Description |
---|---|
Name | The name of the CMDB Sync connection |
Access Mechanism | The access mechanism to use to connect to the CMDB:
Select the mechanism to use for the connection. The UI refreshes to provide the correct options for the access mechanism that you selected. |
Username | The user name of the CMDB user that is at least a member of a group having the At minimum, the CMDB Demo user permissions are required for multitenancy to work. A user is not permitted to connect to the CMDB from a second IP address within 4 hours of their last activity at the first IP address. For a failover scenario, you could also create a second discovery user to connect from the failover appliance.
|
Password | The password of the CMDB user (or blank if the user has no password) |
Options based on connection type
Common options
Field | Description | ||||||
---|---|---|---|---|---|---|---|
Continuous Sync | Select the check box to enable continuous sync for this CMDB connection. During continuous CMDB synchronization, whenever BMC Discovery finishes scanning a device, it is added to the synchronization queue. Similarly, whenever a device node is removed due to aging, it is also queued for synchronization, meaning that the deletion is propagated into the CMDB. In this way, the CMDB stays completely synchronized with BMC Discovery. | ||||||
Batch Size | Enables you to configure the batch size used for batch operations. If you experience timeouts during a batched operation, most likely during a resync, these may be prevented by setting it to a lower value. You can set the batch size to anything between 1 and 1000. The default is 100. | ||||||
Concurrent Workers | Enables you to specify the number of workers used by the CMDB sync process. You can set the number of workers from 1 to 20. The default is 1. The best practice is to start from the default and gradually increase the number up to when sync rate keeps up with discovery rate. | ||||||
Dataset ID | The ID of the dataset used for Discovery data. The default is | ||||||
Data Model | The data model for your CMDB. Different versions of the CMDB have different data models, so the data from BMC Discovery must be transformed differently according to the CMDB version. Select the correct data model from the menu. If you select an incorrect value, you might encounter errors during synchronization.
| ||||||
Multitenancy | Multitenancy support. Selecting this check box enables you to choose a default company name from the drop-down list to assign to a discovery run during an initial scan. The list of companies is not populated until one connection has been successfully tested, or you click Get Companies (which also tests the connection). This section is always displayed. However, if another connection exists, instead of the multitenancy configuration options, a message stating Configure multitenancy from the overview page is displayed along with a link to the CMDB Sync page.
|
Comments