Controlling events displayed in PEM
You can use the allowsendparamonly variable to prevent events from being generated and displayed in the PATROL Event Manager for applications and instances when parameters change state to OK. The allowsendparamonly is defined in the [parm90:AGENT] stanza of the patrol.conf file.
Format and type of data |
Text string (true, false) |
Default value |
None |
Minimum and maximum |
None |
Dependencies |
None |
Recommendation |
None |
The allowsendparamonly variable has the following values:
- True: events are not generated or displayed for applications and instances when a parameter changes to an OK state.
- False: events are generated and displayed for applications and instances when a parameter changes to an OK state.
Note
You must manually create this variable in your patrol.conf file.
Comments
Log in or register to comment.