Objects for parametersTable

The table parametersTable contains these objects:

parametersTable OBJECT-TYPE

SYNTAXSEQUENCE OF ParametersEntry
ACCESSnot accessible
STATUSdeprecated
DESCRIPTION "This table is used to get/set PATROL application instance monitored parameters. PATROL Agent parameters are leaves of the information tree."
: := {patrolObjects 8}

parametersEntry OBJECT-TYPE
SYNTAXParametersEntry
ACCESSnot accessible
STATUSmandatory
DESCRIPTION "The value and description for a given PSL Agent's parameters"
INDEX {applicationOid, applInstOid, parameterObjId}
: := {parametersTable 1}
parametersEntry : := SEQUENCE {
parameterName
parameterState
parameterCurrentTime
parameterCurrentValue
parameterPollingInt
parameterRetries
parameterOutputMode
parameterAutoScale
parameterYaxisMin
parameterYaxisMax
parameterRowStatus
parameterObjId
parameterActiveStat
parameterRunningStat

parameterName OBJECT-TYPE

SYNTAXDisplayString
ACCESSread-only
STATUSmandatory
DESCRIPTION "Parameter name"
: := {parametersEntry 1}

parameterState OBJECT-TYPE

SYNTAXStates
ACCESSread-only
STATUSmandatory
DESCRIPTION "Parameter state"
: := {parametersEntry 2}

parameterCurrentTime OBJECT-TYPE

SYNTAXTimeTicks
ACCESSread-only
STATUSmandatory
DESCRIPTION "Time stamp when the current value was produced"
: := {parametersEntry 3}

parameterCurrentValue OBJECT-TYPE

SYNTAXDisplayString
ACCESSread-only
STATUSmandatory
DESCRIPTION "Parameter's current value"
: := {parametersEntry 4}

parameterPollingInt OBJECT-TYPE

SYNTAXINTEGER
ACCESSread-only
STATUSmandatory
DESCRIPTION "Parameter polling interval"
: := {parametersEntry 5}

parameterRetries OBJECT-TYPE

SYNTAXINTEGER
ACCESSread-only
STATUSmandatory
DESCRIPTION "Parameter timeout retries"
: := {parametersEntry 6}

parameterOutputMode OBJECT-TYPE

SYNTAXOutputMode
ACCESSread-only
STATUSmandatory
DESCRIPTION "Parameter output mode"
: := {parametersEntry 7}

parameterAutoScale OBJECT-TYPE

SYNTAXPBoolean
ACCESSread-only
STATUSmandatory
DESCRIPTION "True(1) means to use automatic scale. False(0) means to use the following YaxisMin and YaxisMax fields to draw y-axis scale."
: := {parametersEntry 8}

parameterYaxisMin OBJECT-TYPE

SYNTAXINTEGER
ACCESSread-only
STATUSmandatory
DESCRIPTION "Minimum value for drawing y-axis scale if parameterAutoScale is false(0)"
: := {parametersEntry 9}

parameterYaxisMax OBJECT-TYPE

SYNTAXINTEGER
ACCESSread-only
STATUSmandatory
DESCRIPTION "Maximum value for drawing y-axis scale if parameterAutoScale is false(0)"
: := {parametersEntry 10}

parameterRowStatus OBJECT-TYPE

SYNTAXPRowStatus
ACCESSread-write
STATUSmandatory
DESCRIPTION "Row status for creating a new row as defined in SNMP V2"
: := {parametersEntry 11}

parameterObjId OBJECT-TYPE

SYNTAXINTEGER
ACCESSnot accessible
STATUSmandatory
DESCRIPTION "Parameter object id"
: := {parametersEntry 12}

parameterActiveStat OBJECT-TYPE

SYNTAXPBoolean
ACCESSread-write
STATUSmandatory
DESCRIPTION "Boolean value of the parameter explaining whether the parameter was created as active"
: := {parametersEntry 14}

parameterRunningStat OBJECT-TYPE

SYNTAXPBoolean
ACCESSread-write
STATUSmandatory
DESCRIPTION "Boolean value indicating the parameter is either running or suspended for the current instance"
: := {parametersEntry 15}