Integration variables
In the PATROL Agent Configuration Utility, these variables are located in /AgentSetup/integration.
/AgentSetup/integration variables
Note
If you need to change the values for these variables, you must create configuration variables and assign new values.
Variable | Description | Format | ||||
---|---|---|---|---|---|---|
integrationMaxNumRetries | Specifies the maximum number of times a PATROL Agent tries to connect to an Integration Service.
| Numeric | ||||
perIntegrationMaxNumRetries | Specifies the maximum number of times a PATROL Agent tries to connect to the same Integration Service. Once the maximum number of retries is exhausted, the PATROL Agent attempts to connect to the next configured Integration Service. Default value 2 | Numeric | ||||
integrationRetryPeriod | Represents the time period between connection attempts to the Integration Service. | Numeric | ||||
integrationConnectTimeout | Number of seconds to wait before giving up on a connection request with the Integration Service | Numeric | ||||
publishHostName | Contains the user-defined string for the PATROL Agent that is published (displayed) to Integration service.
| Text string | ||||
integrationServices | Contains integration service string (tcp:host:port) to which PATROL Agent will bind. | |||||
denyCfg | Controls the configuration of PATROL Agent through the Infrastructure Monitoring Administration in the TrueSight environment. For more information, see Controlling the configuration of PATROL Agent. | Boolean | ||||
sendAllConnectDisconnectEvent |
The default value is No. | Text string |