Displaying and logging PEM connection messages

The /AgentSetup/suppressConsoleInfoMsgMask variable controls whether PEM messages are logged in the agent error log and are displayed in the PEM Console or excluded from the log and not displayed in the PEM Console. Suppressing messages is sometimes necessary because various applications generate numerous events.

Values

Specify the connection modes for which the agent blocks informational messages. Possible modes include:
C — configuration
D — developer
O — operator
P — PEM

Default value

P (PEM)

Minimum and maximum

Not applicable

Dependencies

None

Recommendation

To view all messages and record them in the log file, set this variable equal to an empty string (" ").