Event filter parameters not automatically acknowledged

Event filter parameters are not automatically acknowledged even though the event filter is configured to do so, as specified on the Event Handling tab of the Configure Windows Event Monitoring window.

This behavior occurs for the following parameters:

  • ELMErrorNotification
  • ELMFailureAuditNotification
  • ELMInformationNotification
  • ELMNotification
  • ELMOtherTypesNotification
  • ELMSuccessAuditNotification
  • ELMWarningNotification
  • ELMCriticalNotification
  • ELMVerboseNotification

Explanation

Solution

These parameters cannot be automatically acknowledged.

Deselect the option to notify PATROL immediately when an event that matches the filter occurs.

You cannot use the auto-acknowledge feature if the event filter is configured to notify immediately.

For more information about this setting, see Configuring Windows events monitoring.