Troubleshooting the BEM adapter
This topic provides information for troubleshooting issues specific to the BMC Atrium Orchestrator application adapter for BMC Event Manager (BEM).
Message: Event with WARNING severity received by the BMC Atrium Orchestrator Monitor Adapter for BEM but slot severity in event is not received.
Explanation: WARNING is the default severity value in the BMC Event Manager application.
User response: To resolve this issue, you must add a configuration parameter to the gateway.imcomm file as follows:
- Access the computer on which BMC Event Manager is installed and navigate to the $MCELL_HOME/etc directory.
- Open the gateway.imcomm file and then add
cond=always
. - Restart the BMC Event Manager service.