Default language.

Flashboard display errors


This section describes some of the display-related BMC Remedy Flashboards error messages. The messages are displayed in the Flashboard field on the form or as a separate message box.

  • Page cannot be displayed
    • Is the BMC Remedy Mid Tier running and functioning correctly?
    • Did you enter the default web path in the Advanced tab of the AR System Administration: Server Information form?
  • Could not log into the server
     Is the BMC Remedy AR System server running and functioning correctly?
  • Cannot display a graph that contains more than 3000 data points
     The number of data points to be plotted on a flashboard exceeds a configurable limit set by Microsoft. The default is 3000 data points.
     To increase this limit, add the following property to the config.properties file, which is located in the midTierInstallDirectory/WEB-INF/classes directory:
    flashboards.maxDataPoints=numberOfDataPoints

    For example:
    flashboards.maxDataPoints=4000 

    Warning

    Note

    Do not exceed 10,000 points.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*

Remedy Action Request System 20.02