Configuring Approval Server to work with flowcharts
- On the AR System Server Administration Console, select System > General > Server Information.
- On the Ports and Queues tab, check whether a Plugin Loopback RPC Program Number and a RPC private port have been defined for BMC Remedy Approval Server.
The values of Min Threads and Max Threads for the RPC private port should be greater than one. Check whether the same ports are used in the approval Private AR Server RPC Socket and Plugin Loopback RPC Socket settings on the AP:Admin-ServerSettings form.
- On the Advanced tab, set the Default Web Path to:
http:// <ARSystemServerName>:8080/arsys
For more information, see Configuring AR System servers. - On the Basic tab of the AP:Process Definition form, select a value from the Generate Preview list.
- On the General Settings page of the BMC Remedy Mid Tier Configuration Tool:
- Set the Data Visualization Module Server to the server where the Visualizer plug-in is installed.
Select the appropriate authentication server.
See Setting external authentication options.
The flowchart view is compatible with BMC Remedy Mid Tier 7.1.00 and 7.0.01. You can use BMC Remedy Mid Tier to display the flowchart view for an approval request.